INSTALLER/CONFIGURATION MENU  
a time delay built in and do not require this feature to be  
activated in the thermostat.Your compressor manufactur-  
er can tell you if this lockout feature is already present in  
their system. When the thermostat compressor time delay  
is activated, it will flash the set point for up to five minutes.  
12. Select Continuous Display Lighting (dL) – In low  
lighting conditions, display backlight improves the display  
contrast. When C terminal is connected, selecting dL On  
will turn the display light on continuously. Selecting dL  
Off will turn the display light on momentarily after any  
key is pressed. When C terminal is not powered (battery  
only), dL On enables the momentary backlight whenever  
a key is pressed.  
humidity allowing a slightly higher temperature to feel  
comfortable. As the peak load subsides, this feature also  
takes advantage of the air conditioner's increased capacity  
under more efficient conditions to gradually reduce the off-  
set back to zero and return control to the selected setpoint  
temperature.  
If Cool Savings is selected off, no temperature offset  
will occur.  
21. Compressor Optimization – (Not available on earlier  
models) CO provides a delay in circulator fan operation  
after the compressor turns on or off. With CO selected  
ON, when the compressor turns on (for a call for heat  
in heat pump or a call for cool) the fan will be delayed  
for five seconds before turning on to allow the air to be  
heated or cooled. After the compressor turns off for call  
for cool, the fan will continue to run for 20 seconds to  
capture additional cooling from the system. If CO is set to  
OFF, there will be no delay in fan operation.  
Continuous Display Lighting without common wire  
connection – When thermostat is Battery Powered with  
Power Stealing assist with low voltage 24V connections  
to both W and Y terminals, selecting dL "On" will provide  
continuous display light.  
Note: If power stealing operation is not compatible with either  
the W or Y connection (see page 2), or if only a single  
connection to W or Y, continuous display light will be  
interrupted when the active power stealing connection (W  
or Y) is operating the system. In power stealing mode, the  
continuous display light will increase in brightness when a  
button is pressed. And on some systems with high imped-  
ance, the display light may dim slightly when thermostat  
is calling for heat or cool.  
13. Select Temperature Display Adjustment 5 LO to 5 HI  
This allows you to adjust the room temperature display  
by -5°F to +5°F in 1° steps.Your thermostat was accu-  
rately calibrated at the factory, however you have the  
option to change the display temperature value to match  
the previous thermostat, if you so prefer.  
14. Select °F or °C Readout – Changes the display readout  
to Celsius or Fahrenheit as required.  
15. Select Audio Prompting (Beeper) On or Off – Factory  
default setting is b, On. If you wish to turn off the beeper  
select OFF.  
16. Select Daylight Saving Time Calculation – This feature  
will allow the thermostat to calculate the DST automatically  
and apply it to the Real Time Clock display. Default is On.  
17 & 18. Select Automatic Schedule – Not available if  
configured for non-programmable. This feature allows  
programming a “Comfort Temperature” into all program  
periods with the Auto Schedule key. When Heat AS  
(for Heat mode) or Cool AS (for Cool mode) is selected  
On, the Auto Schedule feature is ready to be set. Off  
indicates that the feature is not ready to be used or a  
“Comfort Temperature" is already set. See Auto Schedule  
in Programming section.  
22. Comfort Alert with Active Protection – (not available  
on earlier models) Turn this feature ON to enable active  
protection. This allows the thermostat to identify fault  
codes sent by the Comfort Alert module when compres-  
sor damage is possible and react to those codes by  
turning the compressor off. Fault codes from the Comfort  
Alert module will flash on the thermostat. (Refer to Com-  
fort Alert Codes in Troubleshooting section.) If a Comfort  
Alert module is not connected, or to disable active protec-  
tion, turn this feature OFF. If a Comfort Alert module is  
connected and this feature is turned OFF, the thermostat  
will still receive and flash the fault codes from the Comfort  
Alert module, but the active protection will not be enabled  
to protect the compressor.  
23. Heat Temperature Limit Range – This feature adjusts  
the highest setpoint temperature for heat. The default set-  
ting is 99°F. It can be changed to a setting between 62°F  
and 98°F. The "temperature limit" icon will be displayed  
to the left of your setpoint temperature when using this  
feature. The "temperature limit" icon will flash if an  
attempt is made to adjust the temperature beyond the  
range selected.  
24. Cool Temperature Limit Range – This feature adjusts  
the lowest setpoint temperature for cool. The default  
setting is 45°F. It can be changed to a setting between  
46°F and 82°F. The "temperature limit" icon will be dis-  
played to the left of your setpoint temperature when using  
this feature. The "temperature limit" icon will flash if an  
attempt is made to adjust the temperature beyond the  
range selected.  
25 & 26. Keypad Lockout – This step allows you to select  
the type of lockout or limited range security required. If no  
19 & 20. Select Cool Savings™ – Cool Savings™ provides an  
energy saving temperature offset (from 1-6 degrees) under  
peak cooling load conditions (high outdoor temperatures).  
If selected on, Cool Savings™ becomes active when the  
air-conditioner runs for periods of longer than 20 minutes.  
When active, Cool Savings™ gradually offsets the indoor  
temperature display downward. The first 1° of adjustment  
will take one hour of continuous air conditioner run time  
with subsequent 1° adjustments occurring with each ad-  
ditional half hour of run time (ex for a 2° offset, the air con-  
ditioner would need to run continuously for 1 ½ hours). The  
offset is limited to the number of degrees you select from  
1 up to 6. When an offset starts or is active, “Cool Savings”  
will flash on the display.  
lockout or limited range security is required, press  
advance the menu.  
to  
Three security settings are available in this menu item.  
Use the or keys to select the lockout desired.  
Lockout selections are:  
"Keypad Lockout and L" = Total Lockout. Total Lockout  
locks all keys.  
"Keypad Lockout and P" = Partial Lockout. Partial Lock-  
out allows only the  
set temperature limits.  
or  
keys to operate within your  
"Temperature Limit/Keypad Lockout" prevents chang-  
ing the temperature limits in the Configuration Menu.  
After the type of lockout is selected, press  
Keypad Lockout Combination Number Selection  
.
The principle of this energy saving feature takes advantage  
of the long air conditioning run times lowering the indoor  
Display will read "000" "Keypad Lockout".  
8