Home > OH > OH-1202H Universal Humidity Touchscreen Thermostat Instruction Manual

OH-1202H Universal Humidity Touchscreen Thermostat Instruction Manual

PROGRAMMING  
Worksheet for Re-Programming 5+1+1 and 7 Day Program  
Heating  
Program  
Wake Up  
(Morning)  
Leave For Work  
(Day)  
Return Home  
(Evening)  
Go To Bed  
(Night)  
Fan  
Fan  
Fan  
Fan  
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F  
Auto  
MON  
TUE  
WED  
THU  
FRI  
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F  
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F  
Auto  
Auto  
SAT  
SUN  
Cooling  
Program  
Wake Up  
(Morning)  
Leave For Work  
(Day)  
Return Home  
(Evening)  
Go To Bed  
(Night)  
Fan  
Fan  
Fan  
F
a
n
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F  
Auto  
MON  
TUE  
WED  
THU  
FRI  
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F  
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F  
Auto  
Auto  
SAT  
SUN  
Wired Remote Temperature Sensing  
temperature shown on the display will be from the thermostat,  
LS On, or the remote sensor LS Off.  
One remote temperature sensor can be installed indoor or  
outdoor and connected to the thermostat by a maximum  
cable length of 100 meters (300 feet). Terminals +, S and - on  
the terminal block allow connection of the remote sensor.  
The thermostat must have 24 VAC Common connection to  
terminal C for the remote sensor to operate. The remote sen-  
sor can be enabled or disabled in the Installer/Configuration  
menu, item 29.  
In normal operation, when a remote sensor is enabled the  
time digits of the display will alternate between the time and  
the remote temperature for three seconds each. Above the  
remote temperature will be Remote, for indoor sensor or  
Outdoor Remote, for outdoor sensor. If the remote sensor is  
an indoor sensor and the local display has been disabled, the  
temperature displayed as the room temperature will be the  
remote sensor temperature.  
When remote sensor, Remote, is selected Off (factory de-  
fault), no remote sensor is enabled. When remote sensor is  
selected On, the next step is to select the remote as indoor,  
Remote In, or outdoor, Outdoor Remote. If the remote is se-  
lected as Remote In, an additional step will be to select if the  
Sensing Range:  
Outdoor temperature range is -40oF to 140oF  
Indoor temperature range is 32oF to 99oF  
14  
GeneralDetails
NameOH-1202H Universal Humidity Touchscreen Thermostat Instruction Manual
MakeOH
LanguageEnglish
FiletypePDF (Download)
File size0.42 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...