INSTALLER/CONFIGURATION MENU  
again. This dehumidification feature may use more energy  
by making dehumidification a priority initiating a call for  
cooling if humidity is 2% above desired setting. This  
feature may also over-cool the condition space by up to 3  
degrees to achieve the desired humidity level. (Note: Both  
dehumidification modes operate in Cooling mode only  
with a call for cooling)  
“HM” terminal) if the actual humidity is below the humid-  
ity set point. The display indicates AH. Pressing the  
key will cycle the display from OFF to H (feature enabled  
in Heat mode) to C (feature enabled in Cool mode) to A  
(feature enabled to Auto mode) and back to OFF.  
42. Cycle Humidifier (CH) – This feature provides an op-  
tion that reduces the water usage by up to 50% when a  
flow-through humidifier is controlled by the thermostat. It  
is recommended for use on flow-through humidifiers only.  
The display indicates CH (Cycle Humidifier) with the de-  
44 & 45. Change UV Lamp – This feature allows the thermo-  
stat to display the words "Change UV Lamp" (Call for  
Service of UV bulb) after a set time of UV bulb operation.  
This is a reminder to maintain your UV system at opti-  
mum level of operation. When enabled, the factory set  
interval for "Change UV Lamp" to be displayed is 350  
days of UV bulb operation and can be adjusted in 25 day  
increments. This should be adjusted with respect to the  
bulb’s recommended maintenance schedule.  
fault indicating OFF. Pressing the  
or  
keys will toggle  
the display from OFF to On and back to OFF. When CH is  
enabled, the humidifier will cycle to turn off for 10 minutes  
after it has run for 10 minutes. The blower and/or furnace  
will continue to run during the humidifier off period.  
43. Programmable Dehumidification Optimal Comfort  
Mode (OC) or Optimal Dehumidification (Od) – This  
item can be selected to OC (Optimal Comfort mode), Od  
(Optimal Dehumidification), or OFF. When Optimal Com-  
fort (OC) is enabled, this feature automatically reduces  
indoor humidity with a call for Cooling if humidity is 2%  
above humidity setpoint. Humidity is set by pressing the  
Humidity key when in the appropriate mode, in this case  
When "Change UV Lamp" is displayed, you can clear it  
by pressing Clean Display.  
46 & 47. Change Humidifier Pad – This feature allows the  
thermostat to display the words "Change Pad" after a set  
time of humidifier operation. This is a reminder to main-  
tain or clean your humidifier. The factory set interval for  
"Change Pad" to be displayed is 100 hours of humidifier  
operation. This should be adjusted with respect to the  
humidifier’s recommended maintenance schedule.  
When "Change Pad" is displayed, you can clear it by  
pressing Clean Display.  
48 & 49. Select Change Filter Run Time – This feature  
allows thermostat to display "Change Filter" after a set  
time of blower operation. This is a reminder to change  
or clean your air filter. This time can be set from 25 to  
1975 hours in 25 hour increments. A selection of OFF will  
cancel this feature. When "Change Filter" is displayed,  
you can clear it by pressing Clean Display. In a typical ap-  
plication, 200 hours of run time is approximately 30 days.  
Cooling, and pressing the  
or  
keys to set desired  
humidity (range 40% to 95%) level followed by pressing  
Humidity key again. This dehumidification feature uses  
less energy by maintaining temperature and dehumidify-  
ing only when a call for Cooling is required. Optimal De-  
humidification (Od) when enabled, this feature automati-  
cally reduces indoor humidity with a call for Cooling if  
humidity is 2% above setting. Humidity is set by pressing  
the HUMIDITY key when in the appropriate mode, in  
this case Cooling, and pressing the or keys to set  
desired humidity level followed by pressing Humidity key  
OPERATINGYOUR THERMOSTAT  
Check Thermostat Operation  
NOTE  
Heating/Humidifier  
1. Press SYSTEM key to select HEAT. If the auxiliary heating  
system has a standing pilot, be sure to light it.  
To prevent static discharge problems, touch side of  
thermostat to release static build-up before touching  
any keys.  
2. Press  
to adjust thermostat setting to 1° above the  
room temperature. The heat pump system should begin to  
operate. The display should show "System On". How-  
ever, if the system configuration is set to HP1 or HP2  
and setpoint temperature display is flashing, the 5 minute  
compressor lockout feature is operating (see Configura-  
tion menu, item 11).  
If at any time during testing your system does not operate  
properly, contact a qualified service person.  
Fan Operation  
3. Adjust temperature setting to 3° above room temperature.  
If your system configuration is set at MS2, HP1 or HP2,  
the auxiliary heat system should begin to operate and the  
display will show "System On +2".  
If your system does not have a G terminal connection, skip to  
Heating System.  
1. Turn on power to system.  
2. Press FAN key to ON position. The blower should begin  
to operate.  
4. Press  
to adjust the thermostat below room tempera-  
ture. The heating system should stop operating.  
3. Press FAN key to AUTO position. The blower should  
stop immediately.  
To check the humidifier when System On appears and the  
heating system is running press the HUMIDITY* button once.  
Press  
to adjust the humidity 2% or more above the room  
CAUTION  
!
Donotallowthecompressortorununlessthecompres-  
soroilheatershavebeenoperationalfor6hoursandthe  
system has not been operational for at least 5 minutes.  
humidity level setpoint range. (Humidity setpoint can be  
adjusted from 5 to 50%.) Hum On will appear indicating it is  
calling for the humidifier.  
*Note: If Auto Schedule is displayed instead of Humidity,  
Auto Schedule must be turned off in the Configuration Menu.  
10  
GeneralDetails
NameOH-1202H Universal Humidity Touchscreen Thermostat Instruction Manual
MakeOH
LanguageEnglish
FiletypePDF (Download)
File size0.42 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

OH-1202H Universal Humidity Touchscreen Thermostat Instruction Manual