3. Connect the temperature sensor as shown. Use  
the floor temperature sensor supplied with the  
DITRA-HEAT-E-HK heating cable(s). Any other  
type of sensor used needs to be 300 volt rated  
and meet the other requirements of the electrical  
codes in your region.  
5. Replace the cover and tighten the screw at the  
bottom.  
2. Settings Which Can Be Modified with the Device  
THERMOSTAT INSTALLATION  
APPLICATION SETTINGS  
(Can also be done with the app)  
MANUAL TEMPERATURE  
ADJUSTMENTS  
CONNECT THE THERMOSTAT  
TO THE SCHLUTER® SMART  
THERMOSTAT APP  
Parameter and  
possible settings  
Setting No.  
Name  
Further Explanation  
1. Loosen the screw  
at the bottom and  
remove the faceplate.  
1. Press the dot soft button and hold for 1 second to  
access the menu. Press the appropriate arrow to  
move up and down into the choices and press the  
dot soft button to make a selection and move to  
the next parameter, until reaching the end.  
Temperature unit:  
°F or °C  
(default: °F)  
Installation Manual  
Schluter®-DITRA-HEAT-E-RS1  
To adjust the temperature, press the up or  
down arrow to change the set point temperature.  
1
Temperature  
1. If you do not yet have an account, download  
the Schluter® Smart Thermostat app for iOS or  
Android™ to create an account and add your  
device.  
The thermostat offers 2 temperature regulation modes:  
Control Mode:  
Floor or Ambient  
(default: Floor)  
Floor mode: Regulates floor temperature by means of an external floor  
temp. sensor.  
2
3
Control  
Ambient mode: Regulates ambient temperature by means of an internal  
temp. sensor.  
6. Power up the thermostat. After performing a test  
sequence, the thermostat should display the floor  
temperature. If not, refer to the troubleshooting  
guide in this manual.  
Max. floor temperature limit  
when in Floor control mode or  
in Ambient mode:  
This function limits the floor temperature when in floor control mode  
or in ambient control mode. This is ideal for preventing uncomfortable  
temperatures, or for preserving floor coverings other than ceramic or stone  
tiles. The recommended max. set point temperature for alternative floor  
coverings (e.g. LVT flooring, laminate flooring, etc.) is 82°F or 28°C. When  
reaching 82°F (28°C), “Laminate flooring” will be displayed.  
2. Connect the heating cable to the load terminals  
and the power supply wires to the line terminals  
located on the back of the thermostat. Connect  
the heating cable ground wire to the grounding  
screw in the electrical junction box.  
Max Floor  
Temperature  
41°F to 97°F  
(OFF option, available only in  
ambient control mode)*  
An auxiliary output provides one of three functions for an additional heating  
source:  
2. Tap the menu icon on your smart phone, then  
select “Add Device”  
Auxiliary output:  
OFF, EXP, Fast, Long  
(default: OFF)  
EXP: For connecting one or more Schluter®-DITRA-HEAT-E-RRS power  
modules  
4
5
Aux Output  
Fast and Long: For adding second stage heating when in ambient control  
mode (Please consult our White Paper on this subject in the “Download”  
section of this thermostat on our website.)  
This installation manual is subject to change without notice.  
Please visit www.schluter.com for the latest version.  
4. Use the screws  
provided to secure  
the thermostat  
to the electrical  
junction box.  
Floor temperature sensor:  
10K or 12K  
(default: 10K)  
Floor Sensor  
WARNINGS  
The installation of this thermostat must be performed by qualified personnel  
and comply with the national and local electrical codes and regulations.  
* In floor control mode, the set point  
limit is 97°F (36°C).  
To avoid electric shock, disconnect the heating system power supply at the  
main electrical panel before installation and maintenance of the thermostat.  
3. Follow the steps of the Installation Wizard.  
2
3
4
5
6
7
8
9
GeneralDetails
NameSchluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual
MakeSchluter
LanguageEnglish
FiletypePDF (Download)
File size0.29 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual
Get the free PDF manual for the Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Connect the temperature sensor as shown. Use the floor temperature sensor supplied with the DITRA-HEAT-E-HK heating cable(s). Settings which can be modified with the device. Manual temperature adjustments. Connect the thermostat to the Schluter® Smart Thermostat app. The thermostat offers 2 temperature regulation modes: Control Mode: Floor or Ambient. Floor mode regulates floor temperature by means of an external floor temperature sensor. Ambient mode regulates ambient temperature by means of an internal temperature sensor. Power up the thermostat. After performing a test sequence, the thermostat should display the floor temperature. Max floor temperature limit when in Floor control mode or in Ambient mode prevents uncomfortable temperatures. The installation of this thermostat must be performed by qualified personnel and comply with the national and local electrical codes and regulations.
  • Page 2: Connecting the DITRA-HEAT-E-RRS power module(s) Ground fault protection can detect a current leakage of 5 mA. When a current leakage is detected, the ground fault protection interrupts the power supply. Press any button to turn back ON the thermostat from standby mode. The thermostat will resume operation under its last program settings. Setpoint range is 5° C to 36° C (41° F to 97° F). This thermostat has an Auto Test which periodically verifies the correct operation of the protection circuit. GFCI protection is Class A (5 mA). The Schluter-DITRA-HEAT-E-RRS power module is recommended for more than 15 amps in a room. This device complies with Industry Canada license exempt RSS standard(s).