Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual
3. Connect the temperature sensor as shown. Use
the floor temperature sensor supplied with the
DITRA-HEAT-E-HK heating cable(s). Any other
type of sensor used needs to be 300 volt rated
and meet the other requirements of the electrical
codes in your region.
5. Replace the cover and tighten the screw at the
bottom.
2. Settings Which Can Be Modified with the Device
THERMOSTAT INSTALLATION
APPLICATION SETTINGS
(Can also be done with the app)
MANUAL TEMPERATURE
ADJUSTMENTS
CONNECT THE THERMOSTAT
TO THE SCHLUTER® SMART
THERMOSTAT APP
Parameter and
possible settings
Setting No.
Name
Further Explanation
1. Loosen the screw
at the bottom and
remove the faceplate.
1. Press the dot soft button and hold for 1 second to
access the menu. Press the appropriate arrow to
move up and down into the choices and press the
dot soft button to make a selection and move to
the next parameter, until reaching the end.
Temperature unit:
°F or °C
(default: °F)
Installation Manual
Schluter®-DITRA-HEAT-E-RS1
To adjust the temperature, press the up or
down arrow to change the set point temperature.
1
Temperature
1. If you do not yet have an account, download
the Schluter® Smart Thermostat app for iOS or
Android™ to create an account and add your
device.
The thermostat offers 2 temperature regulation modes:
Control Mode:
Floor or Ambient
(default: Floor)
Floor mode: Regulates floor temperature by means of an external floor
temp. sensor.
2
3
Control
Ambient mode: Regulates ambient temperature by means of an internal
temp. sensor.
6. Power up the thermostat. After performing a test
sequence, the thermostat should display the floor
temperature. If not, refer to the troubleshooting
guide in this manual.
Max. floor temperature limit
when in Floor control mode or
in Ambient mode:
This function limits the floor temperature when in floor control mode
or in ambient control mode. This is ideal for preventing uncomfortable
temperatures, or for preserving floor coverings other than ceramic or stone
tiles. The recommended max. set point temperature for alternative floor
coverings (e.g. LVT flooring, laminate flooring, etc.) is 82°F or 28°C. When
reaching 82°F (28°C), “Laminate flooring” will be displayed.
2. Connect the heating cable to the load terminals
and the power supply wires to the line terminals
located on the back of the thermostat. Connect
the heating cable ground wire to the grounding
screw in the electrical junction box.
Max Floor
Temperature
41°F to 97°F
(OFF option, available only in
ambient control mode)*
An auxiliary output provides one of three functions for an additional heating
source:
2. Tap the menu icon on your smart phone, then
select “Add Device”
Auxiliary output:
OFF, EXP, Fast, Long
(default: OFF)
EXP: For connecting one or more Schluter®-DITRA-HEAT-E-RRS power
modules
4
5
Aux Output
Fast and Long: For adding second stage heating when in ambient control
mode (Please consult our White Paper on this subject in the “Download”
section of this thermostat on our website.)
This installation manual is subject to change without notice.
4. Use the screws
provided to secure
the thermostat
to the electrical
junction box.
Floor temperature sensor:
10K or 12K
(default: 10K)
Floor Sensor
WARNINGS
The installation of this thermostat must be performed by qualified personnel
and comply with the national and local electrical codes and regulations.
* In floor control mode, the set point
limit is 97°F (36°C).
To avoid electric shock, disconnect the heating system power supply at the
main electrical panel before installation and maintenance of the thermostat.
3. Follow the steps of the Installation Wizard.
2
3
4
5
6
7
8
9
| General | Details |
|---|---|
| Name | Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual |
| Make | Schluter |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.29 MB |

Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Connect the temperature sensor as shown. Use the floor temperature sensor supplied with the DITRA-HEAT-E-HK heating cable(s). Settings which can be modified with the device. Manual temperature adjustments. Connect the thermostat to the Schluter® Smart Thermostat app. The thermostat offers 2 temperature regulation modes: Control Mode: Floor or Ambient. Floor mode regulates floor temperature by means of an external floor temperature sensor. Ambient mode regulates ambient temperature by means of an internal temperature sensor. Power up the thermostat. After performing a test sequence, the thermostat should display the floor temperature. Max floor temperature limit when in Floor control mode or in Ambient mode prevents uncomfortable temperatures. The installation of this thermostat must be performed by qualified personnel and comply with the national and local electrical codes and regulations.
- Page 2: Connecting the DITRA-HEAT-E-RRS power module(s) Ground fault protection can detect a current leakage of 5 mA. When a current leakage is detected, the ground fault protection interrupts the power supply. Press any button to turn back ON the thermostat from standby mode. The thermostat will resume operation under its last program settings. Setpoint range is 5° C to 36° C (41° F to 97° F). This thermostat has an Auto Test which periodically verifies the correct operation of the protection circuit. GFCI protection is Class A (5 mA). The Schluter-DITRA-HEAT-E-RRS power module is recommended for more than 15 amps in a room. This device complies with Industry Canada license exempt RSS standard(s).