Home > Schluter > Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual

Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual

IC  
CONNECTING THE  
DITRA-HEAT-E-RRS  
POWER MODULE(S)  
GROUND FAULT PROTECTION  
LEAVING THE STANDBY MODE  
DISCONNECTING THE  
THERMOSTAT FROM THE  
ROUTER OR FROM THE APP  
TECHNICAL SPECIFICATIONS  
APPLE HOME  
NOTES:  
This device complies with Industry Canada license exempt RSS standard(s). Operation is  
subject to the following two conditions: (1) this device does not cause interference, and (2)  
this device must accept any interference, including interference that may cause undesired  
operation of the device.  
Schluter®-DITRA-HEAT  
Thermostat  
Operating voltage:  
120/208/240 Vac, 50/60 Hz  
The thermostat is equipped with a ground fault  
protection that can detect a current leakage of  
5 mA. When a current leakage is detected, the ground  
fault protection is triggered and quickly interrupts the  
power supply to prevent any serious injuries.  
When the thermostat is on standby, press any button  
to turn back ON the thermostat. The thermostat will  
resume operation under its last program settings. A  
thermostat that is placed on standby before a power  
failure will be on standby by default when power is  
restored.  
Controlling  
automatically and away from home requires  
this  
HomeKit-enabled  
accessory  
a
FCC  
Maximum load:  
HomePod, HomePod mini, or Apple TV set up as a  
home hub. It is recommended that you update to the  
latest software and operating system.  
1800 W @ 120 V / 15 A, max.  
3120 W @ 208 V / 15 A, max.  
3600 W @ 240 V / 15 A, max.  
This equipment has been tested and found to comply with the limits for  
a
Class  
B
digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This equipment generates,  
uses and can radiate radio frequency energy and, if not installed and used in accordance with  
the instructions, may cause harmful interference to radio communications. However, there is  
no guarantee that interference will not occur in a particular installation. If this equipment does  
cause harmful interference to radio or television reception, which can be determined by turning  
the equipment OFF and ON, the user is encouraged to try to correct the interference by one or  
more of the following measures:  
3-Year Limited  
Warranty  
Tap the two arrows ( ) simultaneously to  
enter the connection menu. In the connection menu,  
DITRA-HEAT-E-RRS  
DITRA-HEAT-E-RRS  
DITRA-HEAT-E-RS1  
Setpoint range:  
5° C to 36° C (41° F to 97° F)  
hold the two arrows until “Disconnected” is displayed.  
.
Testing the ground fault protection:  
To control this HomeKit-enabled accessory, the  
latest version of iOS or iPadOS is recommended.  
Display range:  
0° C to 50° C (32° F to 122° F)  
This thermostat has an Auto Test which periodically  
verifies the correct operation of the protection circuit.  
You can also do this manually:  
for warranty information.  
• Re-orient or relocate the receiving antenna.  
Resolution:  
0.5° C ( 1° F)  
• Increase the separation between the equipment and receiver.  
TROUBLESHOOTING  
Storage:  
-20° C to 50° C (-4° F to 122° F)  
1) Press the TEST button.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver  
is connected.  
FIRMWARE VERSION  
Note: If the RESET button’s red warning light does not  
turn ON, the test has failed. Turn OFF the power to the  
heating system from the main electrical.  
Auxiliary output:  
24 Vac/Vdc 0.1 A  
CHECK FLOOR SENSOR: Signifies that the  
thermostat is in floor heating mode and there is no  
floor temperature sensor connected to it.  
• Consult the dealer or an experienced radio/TV technician for help.  
To obtain the version of the firmware installed  
into the thermostat: Press the dot soft button  
for one second and press it again repeatedly until  
reaching the diagnostic page.  
GFCI protection:  
Class A (5 mA)  
2) Press the RESET button to restart the thermostat’s  
base  
Protocol:  
Wi-Fi Standard: IEEE 802.11 b/g/n Frequency: 2.4 GHz  
GFCI FAULT: Signifies there is a short-circuit above  
maximum level with at least one conductor.  
OTHER  
DITRA-HEAT-E-RSS  
FCC License:  
2AC7Z-ESPWROOM32  
FACTORY RESET  
NETWORK NOT FOUND: Signifies the SSID  
network can’t be found.  
When requiring more than 15 amps in a room, the  
Schluter®-DITRA-HEAT-E-RRS power module is  
recommended. This power module is the only model  
which can be used with the Schluter®-DITRA-HEAT-  
E-RS1 Smart Thermostat.  
Use of the Works with Apple badge means that an accessory has been designed to work  
specifically with the technology identified in the badge and has been certified by the developer  
to meet Apple performance standards. Apple is not responsible for the operation of this device  
or its compliance with safety and regulatory standards.  
IC License:  
21098-ESPWROOM32  
To perform a reset of all parameters to the factory  
default: Press the dot soft button for one second  
and press it again repeatedly until reaching the  
diagnostic page. From the diagnostic menu, hold the  
Schluter Systems L.P.  
194 Pleasant Ridge Road, Plattsburgh, NY 12901-5841  
Tel.: 800-472-4588 • Fax: 800-477-9783  
Certifications:  
INCORRECT PASSWORD: Signifies the password  
is incorrect.  
Apple, Apple Home, HomeKit, HomePod, HomePod mini, iPad, iPhone, Siri and Apple TV are  
trademarks of Apple Inc., registered in the U.S. and other countries and regions. App Store is a  
service mark of Apple Inc., registered in the U.S. and other countries.  
under the following safety standards:  
UL 60730-1, UL 60730-2-9, UL 943,  
CAN/CSA E60730-1, CAN/CSA-E60730-2-9, CSA C22.2 No.144.1  
Schluter Systems (Canada) Inc.  
21100 chemin Ste-Marie, Ste-Anne-de-Bellevue, QC H9X 3Y8  
Tel.: 800-667-8746 • Fax: 877-667-2410  
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.  
Google, Android and Google Play are trademarks of Google LLC..  
up and down arrow ( ) simultaneously for 10  
seconds. Select “Yes” using the arrows, and confirm  
by pressing the dot soft button.  
USA - Design patent pending  
Canada – Industrial design pending  
The Wi-Fi CERTIFIED™ Logo is a certification mark of Wi-Fi Alliance®  
Item: 660-0740-0000  
10  
11  
12  
13  
14  
15  
16  
17  
18  
GeneralDetails
NameSchluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual
MakeSchluter
LanguageEnglish
FiletypePDF (Download)
File size0.29 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual