Schluter®-DITRA-HEAT
Thermostat
Operating voltage:
120/208/240 Vac, 50/60 Hz
The thermostat is equipped with a ground fault
protection that can detect a current leakage of
5 mA. When a current leakage is detected, the ground
fault protection is triggered and quickly interrupts the
power supply to prevent any serious injuries.
When the thermostat is on standby, press any button
to turn back ON the thermostat. The thermostat will
resume operation under its last program settings. A
thermostat that is placed on standby before a power
failure will be on standby by default when power is
restored.
Controlling
automatically and away from home requires
this
HomeKit-enabled
accessory
a
FCC
Maximum load:
HomePod, HomePod mini, or Apple TV set up as a
home hub. It is recommended that you update to the
latest software and operating system.
1800 W @ 120 V / 15 A, max.
3120 W @ 208 V / 15 A, max.
3600 W @ 240 V / 15 A, max.
This equipment has been tested and found to comply with the limits for
a
Class
B
digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment OFF and ON, the user is encouraged to try to correct the interference by one or
more of the following measures:
3-Year Limited
Warranty
Tap the two arrows ( ) simultaneously to
enter the connection menu. In the connection menu,
DITRA-HEAT-E-RRS
DITRA-HEAT-E-RRS
DITRA-HEAT-E-RS1
Setpoint range:
5° C to 36° C (41° F to 97° F)
hold the two arrows until “Disconnected” is displayed.
.
Testing the ground fault protection:
To control this HomeKit-enabled accessory, the
latest version of iOS or iPadOS is recommended.
Display range:
0° C to 50° C (32° F to 122° F)
This thermostat has an Auto Test which periodically
verifies the correct operation of the protection circuit.
You can also do this manually:
for warranty information.
• Re-orient or relocate the receiving antenna.
Resolution:
0.5° C ( 1° F)
• Increase the separation between the equipment and receiver.
TROUBLESHOOTING
Storage:
-20° C to 50° C (-4° F to 122° F)
1) Press the TEST button.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
FIRMWARE VERSION
Note: If the RESET button’s red warning light does not
turn ON, the test has failed. Turn OFF the power to the
heating system from the main electrical.
Auxiliary output:
24 Vac/Vdc 0.1 A
CHECK FLOOR SENSOR: Signifies that the
thermostat is in floor heating mode and there is no
floor temperature sensor connected to it.
• Consult the dealer or an experienced radio/TV technician for help.
To obtain the version of the firmware installed
into the thermostat: Press the dot soft button
for one second and press it again repeatedly until
reaching the diagnostic page.
GFCI protection:
Class A (5 mA)
2) Press the RESET button to restart the thermostat’s
base
Protocol:
Wi-Fi Standard: IEEE 802.11 b/g/n Frequency: 2.4 GHz
GFCI FAULT: Signifies there is a short-circuit above
maximum level with at least one conductor.
OTHER
DITRA-HEAT-E-RSS
FCC License:
2AC7Z-ESPWROOM32
FACTORY RESET
NETWORK NOT FOUND: Signifies the SSID
network can’t be found.
When requiring more than 15 amps in a room, the
Schluter®-DITRA-HEAT-E-RRS power module is
recommended. This power module is the only model
which can be used with the Schluter®-DITRA-HEAT-
E-RS1 Smart Thermostat.
Use of the Works with Apple badge means that an accessory has been designed to work
specifically with the technology identified in the badge and has been certified by the developer
to meet Apple performance standards. Apple is not responsible for the operation of this device
or its compliance with safety and regulatory standards.
IC License:
21098-ESPWROOM32
To perform a reset of all parameters to the factory
default: Press the dot soft button for one second
and press it again repeatedly until reaching the
diagnostic page. From the diagnostic menu, hold the
Schluter Systems L.P.
194 Pleasant Ridge Road, Plattsburgh, NY 12901-5841
Tel.: 800-472-4588 • Fax: 800-477-9783
Certifications:
INCORRECT PASSWORD: Signifies the password
is incorrect.
Apple, Apple Home, HomeKit, HomePod, HomePod mini, iPad, iPhone, Siri and Apple TV are
trademarks of Apple Inc., registered in the U.S. and other countries and regions. App Store is a
service mark of Apple Inc., registered in the U.S. and other countries.
under the following safety standards:
UL 60730-1, UL 60730-2-9, UL 943,
CAN/CSA E60730-1, CAN/CSA-E60730-2-9, CSA C22.2 No.144.1
Schluter Systems (Canada) Inc.
21100 chemin Ste-Marie, Ste-Anne-de-Bellevue, QC H9X 3Y8
Tel.: 800-667-8746 • Fax: 877-667-2410
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
Google, Android and Google Play are trademarks of Google LLC..
up and down arrow ( ) simultaneously for 10
seconds. Select “Yes” using the arrows, and confirm
by pressing the dot soft button.
USA - Design patent pending
Canada – Industrial design pending
The Wi-Fi CERTIFIED™ Logo is a certification mark of Wi-Fi Alliance®
Item: 660-0740-0000
10
11
12
13
14
15
16
17
18
| General | Details |
|---|---|
| Name | Schluter DITRA-HEAT-E-RS1 Smart Thermostat Instruction Manual |
| Make | Schluter |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.29 MB |