Schneider SpaceLogic Thermostat Installation Guide
Installation Instructions
SpaceLogic Thermostat TH900 Series Installation Instructions
schneider-electric.com | 1
schneider-electric.com | 2
Specifications (cont.)
Precautions
SpaceLogic Thermostat
TH900 Series for PTAC, Fan Coil, Heat Pump & Gas/Oil Furnace Applications
Regulatory Information
• This product is not intended for life or safety
applications.
FCC CFR 47 Part 15 Subpart B Class B
RSS 247
ICES-003:issue 6
UL 60730-1
UL 60730-2-9
CAN/CSA-E60730-1
CAN/CSA-E60730-2-9
European Conformance CE:
IEC/EN 60730-1
TH903-P-W, TH903-ZP-W, TH903-ZPM-W, TH907-P-W, TH907-ZP-W, TH907-ZPM-W,
TH907-P-B, TH907-ZP-B, TH907-ZPM-B
• Do not install this product in hazardous or
classified locations.
Agency
approvals
• Read and understand the instructions before
installing the product.
• Turn off all power supplying equipment before
working on it.
IEC/EN 60730-2-9
RoHS
2011/65/EU
compliance
2015/863/EU
• The installer is responsible for conformance to
all applicable codes.
REACH
compliance
1907/2006/EC
• External housing may be cleaned with a damp
cloth if it becomes dirty. Do not use any cleaning
agent, especially alcohol.
TH907 Series
TH903 Series
If this product is used in a manner not specified by
the manufacturer, the protection provided by the
product may be impaired. No responsibility is as-
sumed by the manufacturer for any consequences
arising out of the use of this material.
Product Description
Operating temp.
0 to 50°C (32 to 122°F)
Operating
humidity
The TH900 Series thermostats are optimized for
office building, hotel and residential terminal HVAC
control.
0 to 95 % RH (non-condensing)
Storage temp.
Storage humidity
PIR detection
-20 to 60°C (-4 to 140°F)
0 to 90 % RH (non-condensing)
120° (±60°)
The TH900 Series is ideal for PTAC, Fan Coil, Heat
Pump and Gas/Oil Furnace applications.
Dimensions mm (in.)
TH907 Series
PIR detection
distance
10m at 0°, 5m at 60°, 5m at -60°
These models are available in two housing finishes:
optimum (black glass display with capacitive
buttons on a black or white base) or medium (white
glass display with mechanical buttons on a white
base).
120 (4.72)
26.5
(1.04)
Power
consumption
80 (3.15)
Standby < 0.5W
48 (1.86)
120 (4.72)
Power supply
Terminal cable
24 VAC @ 50/60Hz or 24 VDC
14 AWG to 18 AWG solid or
stranded wire
The TH900 Series is a wall surface mount device
that is easy to operate. These thermostats feature
microprocessor-based controls and large LCD
screens which display operation status (cooling,
heating and auto), fan speed, room temperature
and set-point.
Load rating
Protection class
Housing
3A resistive, 1A inductive, 1A pilot duty
IP 30
Flame-retardant PC
120 x 120 x 26.5mm
(4.72 X 4.72 X 1.04 in.)
Dimensions
Front View
Mounting View
Back View
Side View
Pollution degree
Operation type
Control purpose
Pollution Degree 2
Type 1.B
Specifications
TH903 Series
Heat stages
1 stage
120 (4.72)
Operating control
Cool stages
1 stage
26.5
(1.04)
48 (1.86)
120 (4.72)
70 (2.72)
Control
construction
Independently mounted control for flush
mounting
Sensing element
Digital temperature sensor
±0.5°C@0 to 50°C
(±1°F@32 to 122°F)
Impulse voltage
330V
Accuracy
Set-point range
Display range
5 to 35°C (41 to 95°F)
0 to 50°C (32 to 122°F)
Display resolution 0.5°C (1°F)
USA: +1 888-444-1311
Europe: +46 10 478 2000
Asia: +65 6484 7877
Front View
Mounting View
Back View
Side View
© 2020 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Schneider Electric, 35 rue Joseph Monier, F - 92500 Rueil-Malmaison
© 2020 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Schneider Electric, 35 rue Joseph Monier, F - 92500 Rueil-Malmaison
June 2020
F-28128-2 nk
SpaceLogic Thermostat TH900 Series Installation Instructions
SpaceLogic Thermostat TH900 Series Installation Instructions
schneider-electric.com | 3
schneider-electric.com | 4
Wiring
Pin
Name
Color
Typical Function
5. Hook the tabs at the top rear of the unit housing
into the matching depressions at the top of the
Smart Mounting Plate and rotate the bottom of
the housing toward the wall until it snaps into
place.
Installation
Location
Auxiliary input 1, connects
to key card/window switch
with dry contact output. Use
normal close/normal open
configuration to activate.
Select a location about 1.5m (5ft.) above the floor
with good air circulation at average temperature.
Indoor use only. Do not mount thermostat where it
may be affected by:
5
AUX1
Blue
ModBus address
12 VDC. Connects to
external AUX1 or AUX2
switch/sensor with dry
contact output.
6. Secure the housing to the Smart Mounting
Plate with the two small captive screws at the
bottom of the housing.
S1
H3
OFF
ON
6
12V
Red
1
6
• Drafts or dead spots behind doors or in corners
• Hot or cold air from ducts
ModBus
H1
GND
A
6
1
1
B
12
V
H3 White Connector: Low Voltage Signals
7. Apply power to the unit by closing the
applicable supply breaker. After connecting
power, OFF mode (factory default setting) will
appear on the LCD display.
AUX1
AUX2
• Radiant heat from sun or appliances.
• Concealed pipes or chimneys
5
GND
AI
10
Pin
1
Name
B
Color
White
Red
Typical Function
RS485 DATA-
1
• Unheated (un-cooled) areas behind the
thermostat
H2
2
A
RS485 DATA+
Ground
3
GND
Black
Figure 1. Assembly, exploded view
• If Zigbee equipped, do not install near other RF
sources/ transmitters
S1 Black Switch: Modbus Address Settings*
Power/HVAC signal
harness to thermostat
Pin Signal
Typical Function
• When the thermostat is equipped with PIR,
consider view angle, range characteristics, and
mounting position for proper coverage
1
2
3
4
5
6
X1
X2
X3
X4
X5
-
X1=1 if switch is ON, X1=0 if switch is OFF
X2=1 if switch is ON, X2=0 if switch is OFF
X3=1 if switch is ON, X3=0 if switch is OFF
X4=1 if switch is ON, X4=0 if switch is OFF
X5=1 if switch is ON, X5=0 if switch is OFF
Not connected
H1 White Connector: 24 VAC Power/HVAC Signals
Pin
Name
Color
Typical Function
Mounting
24 VAC (dedicated to
heating power)
1
RH
Brown
The HVAC thermostat is typically mounted on a
standard double-gang (4 x 4) junction box. The in-
stallation kit provides a Smart Wall Mounting Plate.
24 VAC (dedicated to
cooling/fan power)
2
3
RC
Violet
*Modbus Address= X1*20 + X2*21 + X3*22 + X4*23 + X5*24
Default address is 0. Adjust address range from 1-31 using
S1, enable Modbus and set baud rate in the User Setup
setting (see User Guide for details).
G3
Grey
Fan speed 3 (high)
If mounted on a single-gang box, use the two cen-
tral holes of the Smart Wall Mounting Plate.
Cooling output (HVAC),
compressor output (heat
pump) or cold water valve
(FCU)
4
Y
Yellow
To mount the HVAC thermostat, complete the
following steps:
4x4 Junction Box
Smart Mounting Plate
Wiring Diagrams
5
6
-
-
Not connected
1. Position the Smart Wall Mounting Plate as
shown in Figure 1.
Note: Prior to beginning an installation, use the
HVAC Wire Harness Templates at the end of this
document to identify the wires/signals coming out
of the 4x4 box and to determine which wires are
connected to which wires on the thermostat. These
templates provide a quick and easy ‘cheat sheet’ to
capture property-specific wiring requirements.
C
Black
Common
Heating output (HVAC),
reversing valve (heat pump)
or hot water valve (FCU)
7
8
W/O/B
G2/W2
Blue
2. Ensure the Smart Mounting Plates are oriented
to follow the marking that says “This side up”.
Snap them together, ensuring all 4 corner snap
hooks are attached, then attach them to the
junction box using the supplied screws.
Fan speed 2 (medium) /
stage 2 heat (heat pump
with aux. heating)
White
24 VAC or 24 VDC
(dedicated to product
power)
If you have technical questions, please contact the
Schneider Electric Customer Care Center in your
country (see schneider-electric.com/contact).
9
R
Red
3. Use wire nuts to connect the Power/HVAC
and other low voltage signal wiring harness
to the power and heat pump/valve/fan control
signal wires within the electrical box. See
the pre-defined commissioning document for
application-specific wire connections.
10
G1
Green
Fan speed 1 (low)
H2 White Connector: Low Voltage Signals
Generic FCU/Conventional HVAC: 24 VAC
Pin
Name
Color
Typical Function
Not connected, reserve for
future use
1
AI
White
4. To connect the unit to the input power and the
relays to the loads, plug the pre-wired power/
HVAC and other signals harness connector into
the female receptacle at the back of the unit
(H1/H2/H3).
2
3
GND
Black
None
Ground
Generic
NC
Not connected
RH_Heating Power
RC_Cooling/Fan Power
G3_High Fan
Brown
Violet
Grey
Auxiliary input 2, connects
to Balcony Door/ External
Occupancy sensor with
dry contact output, two
transitions to activate
GH_HIGH FAN
Y_COOL
Y_Cool Activation
Yellow
G1_Low Fan
Green
Red
GL_LOW FAN
R_24 VAC
4
AUX2
Yellow
R_Product Power
G2/W2_Medium Fan
W/O/B_Heat Activation
C_Common
White
Blue
GM_MEDIUM FAN
W1_HEAT1
Black
C_COMMON
© 2020 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
hneider Electric, 35 rue Joseph Monier, F - 92500 Rueil-Malmaison
© 2020 Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Schneider Electric, 35 rue Joseph Monier, F - 92500 Rueil-Malmaison
| General | Details |
|---|---|
| Name | Schneider SpaceLogic Thermostat Installation Guide |
| Make | Schneider |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.12 MB |

Schneider Drayton Digistat 3rd Generation Wireless Programmable Room Thermostat User Guide

Schneider SpaceLogic Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Installation instructions for SpaceLogic Thermostat TH900 Series. This product is not intended for life or safety applications. Read and understand the instructions before installing the product. Turn off all power supplying equipment before working on it. The installer is responsible for conformance to all applicable codes. The TH900 Series thermostats are optimized for office building, hotel, and residential terminal HVAC control. The TH900 Series is ideal for PTAC, Fan Coil, Heat Pump, and Gas/Oil Furnace applications. These models are available in two housing finishes: optimum or medium. The HVAC thermostat is typically mounted on a standard double-gang junction box. Use wire nuts to connect the Power/HVAC and other low voltage signal wiring harness to the power and heat pump/valve/fan control signal wires within the electrical box.
- Page 2: SpaceLogic Thermostat TH900 Series Installation Instructions Typical HVAC Applications ECO mode minimizes energy consumption when a room is unoccupied and allows for quick resumption when people return. A short press of the FAN button toggles between pre-set fan speeds and fan auto mode. Protection Modes Frost Protection can be enabled or disabled with a setpoint ranging from 5 to 15°C. High Temperature Protection can be enabled or disabled with a setpoint ranging from 25 to 35°C. The default modes displayed by TH900 Series thermostats are OFF and Auto. In Auto mode, the measured ambient temperature is compared to the set point for temperature control. When the fan is operating under automatic control, the applicable fan on/off is chosen based on the temperature difference necessary to achieve the air temperature set point. If the on-board temperature sensor is not operating correctly, ‘Er’ will be displayed on the LCD. Dispose of this device separately from household waste at an official collection point.