OPERATINGYOURTHERMOSTAT
IMPORTANT!
Manual Operation (Bypassing the Program)
Programmable Mode
Choose the Fan Setting (Auto or On or Prog)
Fan Auto is the most commonly selected setting and runs
the fan only when the heating or cooling system is on.
Fan On selection runs the fan continuously for increased air
circulation or to allow additional air cleaning.
Press
or
and the HOLD button and adjust the tempera-
ture wherever you like. This will override the program. The
HOLD feature bypasses the program and allows you to
adjust the temperature manually, as needed. Whatever
Fan Prog will run the fan when the heating or cooling system
is on. In addition, when the thermostat has not called for heat temperature you set in HOLD will be maintained 24 hours a
or cool for more than 60 minutes, it will begin to cycle the fan
for 10 minutes on and 20 minutes off to improve indoor air
quality. This is the Comfort Circulating Fan Feature.
day, until you manually change the temperature or press Run
Schedule to cancel HOLD and resume the programmed
schedule.
Choose the System Setting
Program Override (Temporary Override)
Press
(Cool, Off, Heat, Emer, Auto)
Press the SYSTEM button to select:
Heat: Thermostat controls only the heating system.
or
buttons to adjust the temperature. This will
override the temperature setting for a (default) four hour
override period. The override period can be shortened by
pressing or lengthened by pressing . Program Override
period can range from 15 minutes to 7 days.
Off: Heating and Cooling systems are off.
Cool: Thermostat controls only the cooling system.
Example: If you turn up the heat during the morning pro-
gram, it will be automatically lowered later, when the tempo-
rary hold period ends. To cancel the temporary setting at any
time and return to the program, press Run Schedule.
If the SYSTEM button is pressed to select AUTO the
thermostat will change to Heat or Cool, whichever ran last. If
it switches to heat but you want cool, or it changes to cool
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
but you want heat, press both or
neously to change to the other mode.
buttons simulta-
Emer: Setting is available only when the thermostat is
configured in HP1 or HP2 mode.
Manual Operation for
Non-Programmable Mode
Press the SYSTEM button to select Heat or Cool and use
the
or
buttons to adjust the temperature to your
desired setting. After selecting your desired settings you can
also press the SYSTEM button to select AUTO to allow
the thermostat to automatically change between Heat and
Cool.
PROGRAMMING
Set Current Time and Day
1) Press Menu key to enter installer menu. Then press
Set Time once to indicate hour & A or P designation in
clock display.
Automatic Daylight Saving Calculation
The Real Time Clock will adjust automatically for daylight
savings time, in the following manner:
Increment one hour at 2 AM on the second Sunday of March
and decrement one hour at 2 AM on the first Sunday of
November. (New DST effective 2007).
2) Press and hold either the
or
touch key until you
reach the correct hour and A or P designation.
3) Press Set Time again to display minutes only in clock
display.
The daylight saving feature can be enabled or disabled in
installer configuration menu. Default is dS ON (enabled).
After entering installer configuration mode, momentarily
4) Press and hold either the
reach the correct minutes.
5) Press Set Time once again to display year.
or
touch keys until you
press
actual temperature digits) and on (default – in clock digits).
and keys will toggle display and operation from on to
OFF.
or
touch key until the display indicates dS (in
6) Press and hold either the
reach the correct year.
7) Press Set Time once again to display month.
or
touch key until you
8) Press and hold either the
reach the correct month.
or
touch key until you
9) Press Set Time once again to display date of the month
along with day of the week at top row (which is auto-
matic).
10) Press and hold either the
or
touch key until you
reach the correct day of the month and day of the week
is automatically calculated and displayed at the top row.
11) Press Run Schedule once; now the display will show the
correct time and room temperature.
7
| General | Details |
|---|---|
| Name | White Rodgers 1F95-1277 Big Blue Universal Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual