Home > WHITE RODGERS > White Rodgers 1F95-1277 Big Blue Universal Thermostat Instruction Manual
White Rodgers 1F95-1277 Big Blue Universal Thermostat Instruction Manual
INSTALLATION
Battery Location
WARNING
!
2 "AA" alkaline batteries are included in the thermostat at
the factory with a battery tag to prevent power drainage.
Remove the battery tag to engage the batteries.
To replace batteries, set system to OFF, remove thermostat
from wall and install the batteries in the rear along the top of
the thermostat (see Figure 1). For best results, use a
premium brand "AA" alkaline battery such as Duracell® or
Energizer®.
Thermostat installation and all components of the
control system shall conform to Class II circuits per
the NEC code.
Remove Old Thermostat
A standard heat/cool thermostat consists of three basic parts:
1. The cover, which may be either a snap-on or hinge type.
2. The base, which is removed by loosening all captive screws.
3. The switching subbase, which is removed by unscrewing
the mounting screws that hold it on the wall or adapter
plate. Before removing wires from old thermostat,
label each wire with the terminal designation from
which it was attached. Disconnect the wires from the old
thermostat one at a time. Do not let wires fall back into
the wall.
Figure 1 – Thermostat Base Multi-Stage 1F95-1277
+
S
Mounting
Hole
Mounting
Hole
-
Y2
W2
W/E
6
L
Installing New Thermostat
Place Level
across
Mounting Tabs
(for appearance only)
Place Level
across
Mounting Tabs
(for appearance only)
1. Pull the thermostat body off the thermostat base. Forcing
or prying on the thermostat will cause damage to the unit.
2. Place base over hole in wall and mark mounting hole
locations on wall using base as a template.
Rear view of thermostat
3. Move base out of the way. Drill mounting holes. If you
are using existing mounting holes and the holes drilled
are too large and do not allow you to tighten base snug-
ly, use plastic screw anchors to secure the base.
4. Fasten base snugly to wall using mounting holes shown
in Figure 1 and two mounting screws. Leveling is for
appearance only and will not affect thermostat operation.
5. Connect wires to terminal block on base using
appropriate wiring schematic (see diagram sheet
37-6808).
2 "AA" Batteries
6. Push excess wire into wall and plug hole with a fire re-
sistant material (such as fiberglass insulation) to prevent
drafts from affecting thermostat operation.
7. Carefully line the thermostat up with the base and snap
into place.
WIRINGCONNECTIONS
Refer to equipment manufacturers' instructions for specific
system wiring information. After wiring, see CONFIGURA-
TION section for proper thermostat configuration.
For wiring diagrams, see 37-6808.
Wiring diagrams shown are for typical systems and describe
the thermostat terminal functions.
TERMINAL DESIGNATION DESCRIPTIONS
Terminal Designation
Description
B
. . . . . . . . . . . . . . . . . . Changeover valve for heat pump energized constantly in heating
. . . . . . . . . . . . . . . . . . Changeover valve for heat pump energized constantly in cooling and off
O
Y2 . . . . . . . . . . . . . . . . . . 2nd Stage Compressor
Y
. . . . . . . . . . . . . . . . . . Compressor Relay
. . . . . . . . . . . . . . . . . . Fan Relay
G
RC . . . . . . . . . . . . . . . . . . Power for Cooling
RH . . . . . . . . . . . . . . . . . . Power for Heating
C
. . . . . . . . . . . . . . . . . . Common wire from secondary side of cooling (Optional). Required for fault indication,
continuous backlight operation or remote temperature sensor operation
L
6
. . . . . . . . . . . . . . . . . . Malfunction indicator for systems with malfunction connection
. . . . . . . . . . . . . . . . . . Powered closed 3rd wire for 3-wire zone valve
W/E . . . . . . . . . . . . . . . . . Heat Relay/Emergency Heat Relay (Stage 1)
W2 . . . . . . . . . . . . . . . . . . 2nd Stage Heat (3rd Stage Heat in HP2)
Blank . . . . . . . . . . . . . . . . . Blank
- . . . . . . . . . . . . . . . . . . . Common (DC) for wired remote temperature sensor
S
+
. . . . . . . . . . . . . . . . . . Frequency signal from remote temperature sensor
. . . . . . . . . . . . . . . . . . Power (DC) to remote temperature sensor
2
| General | Details |
|---|---|
| Name | White Rodgers 1F95-1277 Big Blue Universal Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual