from the front). Gently pivot the thermostat up until the six
pin connectors and the plastic snaps lock into place (see
fig. 12). Be gentle when attaching thermostat. If the
thermostat does not seem to be attaching to the subbase
easily, make sure that the connector pins and plastic
snaps are properly aligned, and that excess wire is
pushed into the wall. Damage to the thermostat may
occur if force is used.
ATTACH THERMOSTAT TO SUBBASE
IT IS RECOMMENDED THAT YOU SET OPTION
SWITCHESTODESIREDPOSITIONBEFOREATTACH-
ING ON SUBBASE (see OPERATION). IT IS ALSO
RECOMMENDED THAT YOU PROGRAM THE
THERMOSTAT WITH BATTERIES INSTALLED BE-
FORE ATTACHING ON SUBBASE (see OPERATION
GUIDE for programming instructions).
CAUTION
!
SYSTEM
SWITCH
USE
TO TURN THERMOSTAT OFF BE-
FORE ATTACHING THERMOSTAT TO WALL.
FAILURE TO TURN THERMOSTAT OFF BEFORE
ATTACHING TO WALL MAY CAUSE EQUIPMENT
DAMAGE DUE TO RAPID COMPRESSOR CY-
CLING.
To attach thermostat to subbase, line up the plastic snap
guides at the bottom of the thermostat and the three
connector pins on the thermostat with the connectors
near the bottom left section of the subbase (when viewed
ENGAGE TWO LOWER GUIDES;
PIVOT UP
Figure 12. Attaching thermostat to subbase
OPERATION
Batteries
6-pin connector
SYSTEM CONFIGURATION
A. SET GROUP A OPTION SWITCHES
NOTE
DO NOT REMOVE THE “AA” BATTERIES WHEN
CHANGING GROUP A OPTION SWITCHES. Any
time Group B option switches are changed, the bat-
teriesmustberemovedforaminimumoftwominutes.
(Group A)
(Group B)
1. Total Keypad Activity
Option switches
3-pin connector
ON
Figure 13. Back of thermostat
Switch #1 OFF
Switch #2 OFF
B. SET GROUP B OPTION SWITCHES
1
2
2. Total Keypad Lockout — All thermostat buttons are
disabled.
NOTE
ANY TIME GROUP B OPTION SWITCHES ARE
CHANGED,THE“AA”BATTERIESMUSTBEREMOVED
FOR A MINIMUM OF 2 MINUTES. DO NOT REMOVE
THE BATTERIES WHEN CHANGING GROUP A OP-
TION SWITCHES.
ON
Switch #1 ON
Switch #2 OFF
1
2
3. Limited Temperature Range — Temperature may
beraisedorloweredwithinprogrammedtemperature
limits (temperature adjustment cannot exceed the
lowest cooling or highest heating program tempera-
tures).
1. AutomaticChangeover(Heating/CoolingSystems
Only) — enables thermostat to automatically switch
between heating and cooling programs to maintain
desired room temperature.
ON
ON
Switch #1 ON
Switch #2 OFF
Switch #3 (see step B5)
Switch #1 OFF
Switch #2 ON
1
2
3
1
2
When thermostat is in Limited Temperature Range
only the following buttons are disabled:
ADV
HOLD
TEMP
SET
DAY
PRGM
6
| General | Details |
|---|---|
| Name | WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.13 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual