SPECIFICATIONS  
ELECTRICAL DATA  
Electrical Rating:  
APPLICATIONS  
For use with:  
• Standard heat/cool or heat-only systems  
17 to 30 VAC, 50/60 Hz.  
0.05 to 1.5 Amps  
1.5 Amps Maximum Total Load (All terminals  
combined)  
Anticipation:  
• Three-wire zone valve systems  
• Millivolt systems  
• Electric heat systems  
• Gas or oil fired systems  
• Gas systems with intermittent ignition devices  
(I.I.D.) and/or vent dampers  
Do not use with:  
• Multi-stage systems  
• Heat pump systems  
• Systems exceeding 30 VAC and 1.5 Amps  
Heating 2 to 40  
Cooling 4 to 40  
Reference Values  
}
THERMAL DATA  
Setpoint Temperature Range:  
40°F to 99°F (4°C to 37°C)  
Operating Ambient Temperature Range:  
32°F to 105°F  
Operating Humidity Range:  
0 to 90% RH (non-condensing)  
Shipping Temperature Range:  
-40°F to 150°F  
ACCESSORIES  
Remote Sense Kit W. R. Part No. F145-1049  
Thermostat Guard W. R. Part No. F29-0198 (clear)  
or F29-0238 (opaque)  
INSTALLATION  
1. Probe for obstructions in partition before drilling 12  
NEW INSTALLATION  
hole in wall at selected location. Take up quarter  
round and drill a small guide hole for sighting (see  
3
fig. 1). From basement, drill 4” hole in partition  
You should program the thermostat with batteries  
installed before attaching on subbase. See OPERA-  
TION GUIDE for programming instructions.  
floor next to guide hole. In buildings without base-  
ments, drill 12” hole through ceiling and into parti-  
tion from above.  
SELECT THERMOSTAT LOCATION  
2. Through this hole drop a light chain, or 6” chain  
attachedtoastrongcord.Snagcordinbasementwith  
hooked wire. In buildings without basements, drop  
cord through hole in ceiling and down partitioning;  
snag cord at the thermostat location.  
Proper location insures that the thermostat will provide a  
comfortable building temperature. Observe the following  
general rules when selecting a location:  
1. Locate thermostat about 5 ft. above the floor.  
2. Install thermostat on a partitioning wall, not on an  
outside wall.  
3. Attach thermostat wire to cord and pull wire through  
hole in wall so that 6” of wire protrudes.  
3. Never expose thermostat to direct light from lamps,  
sun, fireplaces or any temperature radiating equip-  
ment.  
4. Avoid locations close to windows, adjoining outside  
walls, or doors that lead outside.  
1
⁄ ” hole for  
2
thermostat wire  
5. Avoid locations close to air registers or in the direct  
path of air from them.  
Stout cord with 6”  
chain attached  
6. Make sure there are no pipes or duct work in that part  
of the wall chosen for the thermostat location.  
Approximately  
5 feet from floor  
Baseboard  
strip moulding  
1
⁄ ” guide hole  
4
for sighting  
7. Never locate thermostat in a room that normally  
warmer or cooler than the rest of the building.  
Quarter round  
removed  
8. Avoid locations with poor air circulation, such as  
behind doors or in alcoves.  
ROUTE WIRES TO LOCATION  
3
⁄ ” hole in floor of partition  
4
NOTE  
Hooked wire for snagging chain  
All wiring must conform with local and national electrical  
codes and ordinances.  
Figure 1. Routing thermostat wires  
2
GeneralDetails
NameWHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.13 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual