T5 Thermostat Instructions  
Before fitting this thermostat, (stat) make sure to read these instructions fully. The installer must be competent and qualified to work with electrics before making any  
connections to mains power. It is the responsibility of the installer to make sure the thermostat is installed in a suitable location, programmed correctly and also suitable  
for use with your chosen heating system. Failure to understand and follow these instructions correctly can cause damage to the thermostat, heating system and create a  
hazardous environment to health. Make sure to check all ratings given in these instructions and also ratings of the heating system this thermostat will be controlling to be  
sure they are all compatible.  
Time  
Days of week  
Auto Porgram Zones 1- 6  
Features  
Specifications  
Set Temprature  
1: Touch screen for easy clean IP rated control. 1: 100-240Vac - 50/60HZ  
2: 0.5 degrees accuracy  
3: Child lock  
Floor Sensor  
2: Max load 16A@250V/AC  
3: Electromagnet Switch Relay  
Actual Temprature  
Heating On  
Holiday Mode  
Manual Mode  
4: Battery backup for program settings  
5: Holiday and Hold Modes  
4: Max temperature range 0-75°C  
5: Default temperature setting range 5-35°C  
6: Internal and external temperature sensors. 6: External NTC 10k Probe  
7: Clear back lit flat screen  
8: Low profile design  
Child Lock  
Automatic Mode  
Power On/Off  
SET  
OK  
Wiring  
OK Button  
SET Button  
Up/Donw Buttons  
Screen Icons & Keys - How to use set and make changes were possible.  
NOTE: Thermostat must be ON and screen LIT UP to operate this thermostat unless stated otherwise.  
Feature  
ON / OFF  
Turn ON/OFF: Quick tap POWER button to turn on and turn off.  
To change the time and day tap the OK button. Minutes will flash, use the UP / DOWN buttons to set the minutes. Once correct tap OK again and the  
hours will flash. Again make changes using UP / DOWN buttons and then tap OK again. Now day will flash, (note the 7 days of the week are represented  
as numbers 1-7 with 1 being Monday) again make changes using UP and DOWN buttons and then tap OK to finish.  
Time / Day  
Manual mode activated. Thermostat will hold the current set temperature unit a change is made. To select Manual mode simple tap the SET button to  
swap between Manual and Auto modes.  
Automated / Programmed heating cycle activated. Stat will continuously run the pre-set automated 7 day heating cycle. To select this simply tap the SET  
button to swap between Auto and Manual modes. See ‘Automated Program Settingsfor how to set up and program the automated heating cycle.  
Automated program - Temporary override. If you wish to manually change the temperature when running the stat in Auto mode simply use the  
UP/DOWN buttons to change the temperature. The new temperature will now be set and held until the next automated program cycle zone kicks in.  
During this temporary override time you will see in the bottom left of the screen. Once this time zone ends and the programed cycle moved into  
the next time zone the thermostat will revert back to the preprogrammed temperature and time cycle. This symbol will then be replaced with  
Holiday mode is used to set a single temperature for a set number for days such as when away on holiday. To set up press and hold OK for 5 seconds to  
enter holiday mode setting. OFF or ON will now be flashing. Use UP / DOWN buttons to select ON and then tap OK. Number of days will then be flashing.  
Use UP/DOWN buttons to select desired number of days and tap OK again. Temperature will be flashing. Select the desired temperature using  
UP/DOWN buttons and tap OK to complete set up. Screen will now revert back to home screen and suitcase will now be showing. To check how many  
days and or time is left before holiday mode ends tap the UP / DOWN button once. NOTE: if you tap the SET button during the holiday mode period,  
holiday mode will be cancelled and the thermostat will revert back to manual mode.  
Child lock to stop unwanted tampering or temperature changes. To activate or turn off simply hold the DOWN button for 5 seconds until the padlock  
appears / disappears.  
When the flame is showing, power is going to heating. The flame will show until the set temperature is achieved. If the set temperature is below the  
actual temperature the flame will not show as there is no need for the heating to be on.  
External NTC sensor / Floor sensor, (not air sensor) is being used to measure main temperature on screen. NOTE: Air or floor or both sensors can be  
selected (see advanced options B for setting options). WHEN USING UNDERFLOOR HEATING IT IS IMPORTANT TO USE FLOOR SENSOR ONLY.  
Read this section on automated program settings fully before trying to program the thermostat.  
NOTE: The thermostat does not turn on or off it simply changes the set / desired temperature 6 times per day on a 7 day cycle.  
NOTE: When programming the thermostat you must work in a linear time line from zone 1 - 6 and not jump back and forward in time.  
NOTE: If you do not want the heating to come on in any part of the day / zone simply set a low temperature for that zone and the thermostat will not turn the heating on  
unless the temperature drops below the set temperature.  
NOTE: For ease of programming you can select a 5+2 (factory default),6+1 or 7 day cycle setting. For more information on this or how to change see advanced options A6.  
NOTE: When programing the thermostat if the screen is left untouched for 10 seconds the thermostat will save changes made and revert back to the home screen. This  
time can be increased in advanced options A - A5 up to 30 seconds before the thermostat saves and reverts back to home screen if more time is needed.  
START: To program each zone hold down SET for 5 seconds and the time will flash and zone 1 will appear in top right corner. The times and temperatures you put into  
the next 6 zones will be copied across to all days showing across the top right of the screen. Follow the next 3 steps below to work through and set all 6 zones for these  
days without delay, (it can be helpful to have your time and temperatures for all zones written down first).  
NOTE: If you have selected 0 (=5+2) in advanced setting A - A6 you will have days 12345 showing across top right of screen at this stage, if you selected option 1 (=6+1)  
you will have days 123456 showing or if you selected optio 2 (=7) you will have days 1234567 showing. The times and temperatures you put into the next 6 zones will be  
copied across to all days showing on your screen. In step 5 below you will compete the missing days 6,7 or 7 if you selected options 0 or 1 in advanced options A - A6  
1: Change the hours using UP/DOWN buttons for when you want to wake up (zone 1 time) and tap SET to move to minutes.  
2: Minutes will flash next, change these again for when you want to wake (zone 1 time) and once correct tap SET to move to temprature.  
3: Set temperature will now flash. Change the temperature to the desired temperature and tap SET again to move / set up next zone..  
4: You will now see Zone 2 appear in the top right and the hours will be flashing again. Repeat steps 1 – 3 above for all 6 zones.  
# If you selected option 0 (=5+2) or 1 (=6+1) in advanced option A - A6 go to instruction step 5 below.  
# If you selected option 2 (=7) in advanced options A - A6 you are finished.  
5: Once you complete zone 6 and tap SET you will now see zone 1 reappear top right but the days will change to weekend days. Days 6+7 or only 7 will now be showing.  
u now need to repeat steps 1-3 above for all 6 zones. These are your weekend zone settings. These days are typically programmed differently to the weekday  
GeneralDetails
NameLiving Heat T5 Touch Screen Digital Smart Thermostat Instructions
MakeLiving Heat
LanguageEnglish
FiletypePDF (Download)
File size0.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Living Heat Wi5 Wi-Fi Digital Heating Thermostat Instructions
Living Heat Wi5 Wi-Fi Digital Heating Thermostat Instructions

Living Heat T5 Touch Screen Digital Smart Thermostat Instructions
Get the free PDF manual for the Living Heat T5 Touch Screen Digital Smart Thermostat Instructions and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Living Heat T5 Touch Screen Digital Smart Thermostat Instructions Overview

Summary of Contents

  • Page 1: T5 thermostat instructions provide essential information for installation and operation. The installer must be competent and qualified to work with electrics before making any connections to mains power. It is the responsibility of the installer to ensure the thermostat is installed in a suitable location and programmed correctly. Failure to follow these instructions can cause damage to the thermostat and create a hazardous environment. Check all ratings given in these instructions and the heating system for compatibility. The thermostat features a touch screen for easy cleaning and has a maximum load of 16A@250V/AC. It includes a child lock, battery backup for program settings, and various modes such as holiday and manual mode. The thermostat does not turn on or off but changes the set temperature six times per day on a seven-day cycle. To program each zone, hold down the SET button for five seconds, and the time will flash. The automated program allows for temporary overrides, and the child lock prevents unwanted tampering.
  • Page 2: zone settings Once you have completed time and temperature for all 6 zones for the weekend days simply tap SET and you have finished. To use the automated mode simply make sure the AUTO symbol is showing and the time and day is correct. Depending upon what type of heating and flooring installed it may be necessary to make changes to the advanced option settings A and/or B to allow optimum control of the heating by this thermostat. To make changes to Advanced Option A settings first turn off the thermostat. Temperature calibration can be adjusted from -9 to +9°C. The thermostat can be set to turn back on or off as per how it was prior to the power cut. The length of time the backlight will stay on can be set from 5 to 30 seconds. Minimum set temperature can be adjusted from 1 to 10°C. If the thermostat is off and temperature drops below the low temperature protection setting, the thermostat will turn heating on to maintain this minimum temperature. To reset the thermostat, enter into setting AE and hold down OK for 5 seconds until the screen shows all symbols together.