Living Heat T5 Touch Screen Digital Smart Thermostat Instructions
V0122
zone settings.
6: Once you have completed time and temperature for all 6 zones for the weekend days simply tap SET and you have finished.
To use the automated mode simply make sure the AUTO symbol is showing and the time and day is correct. The below diagram / table gives a general idea on how we
would suggest programming your thermostats 6 zone times and tempratures daily cycle.
Zone 1-Wake
6:00 24°C
Zone 2-leave
8:00
Zone 3-lunch
11:00 24°C
Zone 4-leave
13:00
Zone 5-dinner
17:00 24°C
Zone 6-sleep
23:00 18°C
16°C
16°C
Depending upon what type of heating and flooring installed it may be necessary to make changes to the advanced option settings A and / or B to allow optimum control
of the heating by this thermostat.
Advanced options A
1: To make changes to Advanced Option A settings first turn off the thermostat. When screen is blank hold SET for 5 seconds and A1 will appear on screen.
2: To move through the settings A1 to AE, tap SET to select the next setting. Once you have the desired setting use the UP/DOWN buttons to make changes to the settings
parameters as per the table below. To move on to the next setting tap SET or to save and exit tap the POWER button.
NO
A1
A2
Setting Options
Data Setting / Function
Factory Default
-1
Temperature Calibration
-9-+9°C - Display temperature can be calibrated if needed.
Start/stop working temperature
difference setting
0.5-5°C - The number of degrees or temperature before the thermostat turns off or on above or below
the current set temperature.
1°C
0
0: - Half lock, only power button still works. 1: - Full lock, all 5 buttons will not function.
A3
A4
Child / Button lock
What state the Thermostat will
turn back on or off after power
cut.
0: - Thermostat to turn back on or off as per how it was prior to the power cut.
1: - Thermostat to switch off after power cut.
2: - Thermostat to switch on after power cut.
0
Backlight On / Screen inactivity
timeout.
5~30s: The length of time the back light will stay on. Or the time the screen will stay in programming
mode until the screen reverts back from programming mode to home screen.
10
0
A5
A6
0 = 5day+2day \1= 6day+1day \ 2 = 7days all the same.
These options group days of the week to help make programming the automated cycle easier.
Example, option 0 = 5 days (week days 1,2,3,4,5 the same) + 2 days (weeked day 6,7 the same).
Automated Program Day
synchronization options.
1-10°C - Lowest possible temperature user can set in manual, holiday or automated modes.
20-70°C Maximum possible temperature user can set in manual, holiday or automated modes.
A7
A8
A9
Minimum Set Temperature.
Maximum Set Temperature.
Low Temperature Protection.
5°C
35°C
5°C
1-10°C - If the thermostat is off and temperature drops below Low Temperature Protection setting
the thermostat will turn heating on to maintain this minimum temperature to help protect from ice,
frost and freezing temperatures.
High Temperature Protection (for 20°C-70°C - If the external sensor detects a temperature above the High Temperature Protection
external sensor only. NOTE: Only setting the thermostat will turn the heating off and the flame will flash to warn user of high
if Advanced options B-BN is set to temperature even if the air sensor or set temperature is showing below this temperature.
45°C
AA
N3 will this setting be activated.
NOTE: Only if Advanced options B - BN is set to N3 will this setting be activated.
High Temperature Protection
Differential.
1-9°C - The temperature or number of degrees the external sensor needs to drop down below the
High Temperature Protection setting before the thermostat turns the heating back on.
2°C
AB
AC
Open Window / Sudden
Temprature Drop Energy Saving.
Off=(--) or 10-20°C - If air sensor detects sudden drop in air temperature by set number of degrees /
temperature the thermostat will turn off the heating to save power for a set length of time specified
in advanced options A - AD below.
-- (=off)
Open Window / Sudden
Temprature Drop Off Time.
10-20min - Length of time the heating will turn off before tuning back on to save power if sudden
drop in air temperature is detected, also see setting A - AC above.
10
A0
AD
AE
To reset the thermostat simply enter into setting AE and make sure Ao in top right of screen is
flashing. Then hold down OK for 5 seconds until the screen briefly shows all symbols together and
then turn off. The unit is now reset to its original factory default settings. .
Reset Thermostat to Factory
Default Settings.
Advanced options B
Sensor Fault Codes
1: To make changes to Advanced Option B settings first turn off the thermostat. When screen is blank hold
OK for 5 seconds and BN will appear on screen.
E1 = Problem with internal / air sensor.
E2 = Problem with or missing external / floor sensor.
2: To move through the settings BN to BO, tap SET to select the next setting. Once you have moved to the
desired setting use the UP/DOWN buttons to make changes to the settings parameters as per the table
below. To move to next setting tap SET or to save and exit tap the POWER button.
NO
BN
Setting Options
Factory Default
N1
Data Setting / Function
N1: Internal sensor
N2: External sensor
Sensor Type /
Internal = Air
External = Floor
N3: Internal + External sensor - (When setting N3 is selected, Internal sensor controls temperature
and external sensor limits max temperature to high temperature protection setting, see Advanced
options A - AA for max temperature setting details).
0:Disable descaling function.
1:Enable descaling function / for water heater use only.
0
BC
BO
Descaling function
Not in use.
Programmer use only / Not in use
Not in use.