Home > WHITE RODGERS > White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions

White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions

PROGRAMMINGYOUR THERMOSTAT  
CONTINUED FROM SEVENTH PAGE  
8
Symptom  
Possible Cause  
Corrective Action  
No Heat (continued)  
5. Heating system requires service or ther-  
mostat requires replacement.  
Diagnostic: Set System Switch to HEAT and raise the  
setpoint above room temperature. Within a few seconds  
the thermostat should make a soft click sound. This  
sound usually indicates the thermostat is operating  
properly. If the thermostat does not click, try the reset  
operation listed above. If the thermostat does not click  
after being reset contact your heating and cooling service  
person or place of purchase for a replacement. If the  
thermostat clicks, contact the furnace manufacturer or a  
service person to verify the heating is operating correctly.  
No Cool  
1. System Switch not set to COOL.  
Set System Switch to COOL and lower setpoint  
below room temperature.  
2. Loose connection to thermostat or system. Verify thermostat and system wires are securely  
attached.  
3. Cooling system requires service or  
thermostat requires replacement.  
Same procedure as diagnostic for No Heat condition  
except set the thermostat to COOL and lower the setpoint  
below the room temperature. There may be up to a five  
minute delay before the thermostat clicks in Cooling.  
Heat, Cool or Fan Runs Constantly.  
1. Possible short in wiring.  
Check each wire connection to verify they are not short-  
ed or touching together. No bare wire should stick out  
from under terminal screws. Try resetting the thermostat  
as described above. If the condition persists the manufac-  
turer of your system or service person can instruct you on  
how to test the Heat/Cool system for correct operation. If  
the system operates correctly, replace the thermostat.  
2. Possible short in thermostat.  
3. Possible short in heat/cool/fan system.  
4. Fan Switch set to Fan On.  
Furnace (Air Conditioning) Cycles  
Too Fast or Too Slow (narrow or wide  
temperature swing)  
1. The location of the thermostat and/or the  
Digital thermostats normally provide precise temperature  
size of the Heating (Cooling) System may control and may cycle faster than some older mechanical  
be influencing the cycle rate.  
models. A faster cycle rate means the unit turns on and  
off more frequently but runs for a shorter time so there is  
no increase in energy use. If you would like to increase  
the cycle time, clip Jumper W-905 as mentioned in the  
instructions for Hydronic Heating Systems. It is not pos-  
sible to shorten the cycle time. If an acceptable cycle rate  
is not achieved as received or by clipping W-905 contact  
a local service person for additional suggestions.  
Thermostat Setting and Thermostat  
Thermometer Disagree  
1. Thermostat thermometer setting requires  
adjustment.  
Thermostat thermometer can be adjusted +/-3 degrees.  
See Temperature Display Adjustment in the Operation  
section  
Thermostat Does Not Follow Program 1. AM or PM set incorrectly in program.  
2. AM or PM set incorrectly on the clock.  
Check current clock and program settings including the  
AM or PM designations for each time period. If a voltage  
spike or a static discharge occurs use the Reset Opera-  
tion listed above.  
3. Voltage spike or static discharge..  
Blank Display and/or Keypad  
Not Responding  
1. Voltage spike or static discharge,  
Use the Reset Operation listed above.  
HOMEOWNER HELP LINE: 1-800-284-2925  
White-Rodgers is a division  
of Emerson Electric Co.  
The Emerson logo is a  
trademark and service mark  
of Emerson Electric Co.  
GeneralDetails
NameWhite Rodgers 1F72 5 2 Day Programmable Thermostat Instructions
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.26 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions