Home > WHITE RODGERS > White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions

White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions

CheckYour Programming  
Follow these steps to check your thermostat programming one  
final time before beginning thermostat operation.  
PROGRAMMINGYOUR THERMOSTAT  
CONTINUED FROM SIXTH PAGE  
6
1. Move SYSTEM switch to HEAT position.  
9. Repeat steps 4 through 8 to complete weekend heating pro-  
gramming.  
2. Press PRGM to view the 1st weekday heating period time and  
temperature. Each time you press PRGM, the next heating  
period time and temperature will be displayed in sequence for  
weekday, then weekend program periods (you may change  
any time or temperature during this procedure).  
10. When you have completed entering your heating program,  
press RUN.  
Enter Cooling Program  
Iftheoutsidetemperatureisbelow5F,disconnectpower  
to the cooling system before programming. Energizing  
the air conditioner compressor during cold weather may  
cause personal injury or property damage.  
3. Press RUN.  
4. Move SYSTEM switch to COOL position.  
5. Repeat step 2 to check cooling temperatures.  
6. Press RUN to begin program operation.  
1. Move SYSTEM switch to COOL position.  
2. Follow the procedure for entering your heating program, using  
your selected cooling times and temperatures.  
YOURTHERMOSTAT IS NOW COMPLETELY PROGRAMMED  
AND READY TO AUTOMATICALLY PROVIDE MAXIMUM  
COMFORT AND EFFICIENCY!  
SPECIFICATIONS  
7
ELECTRICAL DATA  
THERMAL DATA  
Electrical Rating:  
20 to 30 VAC 50/60 Hz.  
Setpoint Temperature Range:  
45°F to 90°F (7°C to 32°C)  
Operating Ambient Temperature Range:  
32°F to 105°F  
0.05 to 1.0 Amps (Load per terminal)  
1.5 Amps Maximum Total Load (All terminals combined)  
Operating Humidity Range:  
0 to 90% RH (non-condensing)  
Shipping Temperature Range:  
-40°F to 150°F  
TROUBLESHOOTING  
8
and still does not function correctly contact your heating/cooling  
service person or place of purchase.  
Reset Operation  
If a voltage spike or static discharge blanks out the display or  
causes erratic thermostat operation you can reset the thermostat  
Batteries  
For optimum performance, we recommend replacing batteries  
once a year with fresh “AAA” alkaline batteries.  
bypressing  
the factory defaults. If the thermostat has power, has been reset  
,
andTIMEatthesametime.Thisalsoresets  
Symptom  
Possible Cause  
Corrective Action  
No Heat/No Cool/No Fan  
(common problems)  
1. Blown fuse or tripped circuit breaker.  
2. Furnace power switch to OFF.  
Replace fuse or reset breaker.  
Turn switch to ON.  
Replace door panel in proper position to engage safety  
interlock or door switch.  
3. Furnace blower compartment door or  
panel loose or not properly installed.  
No Heat  
1. Pilot light not lit.  
Re-light pilot.  
2. System Switch not set to HEAT.  
Set System Switch to HEAT and raise setpoint above  
room temperature.  
Verify thermostat and system wires are securely  
attached.  
3. Loose connection to thermostat or system.  
4. Furnace Lock-Out Condition. Heat may  
also be intermittent.  
Many furnaces have safety devices that shut down  
when a lock-out condition occurs. If the heat works  
intermittently contact the furnace manufacturer or local  
service person for assistance.  
7
GeneralDetails
NameWhite Rodgers 1F72 5 2 Day Programmable Thermostat Instructions
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.26 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions