White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions

3. SelectTemperature Display Adjustment 3 LO to 3 HI – Allows  
you to adjust the room temperature display up to 3° higher or lower.  
Your thermostat was accurately calibrated at the factory but you  
have the option to change the display temperature to match your  
previous thermostat. The current or adjusted room temperature  
will be displayed on the left side of the display.  
CHECK THERMOSTAT OPERATION  
CONTINUED FROM FOURTH PAGE  
5
12 EMER is displayed flashing when the system switch is in EMER  
position.  
13  
Alternately displays current time and temperature.  
4. Select Backlit Display – (Not available on earlier models) The  
display backlight improves display contrast in low lighting condi-  
tions. Selecting backlight ON will keep the light on continuously.  
Selecting Backlight OFF will keep the light off.  
14 The word HOLD is displayed when the thermostat is in the  
HOLD mode.  
15 Displays currently programmed set temperature (this is blank  
when SYSTEM switch is in the OFF position).  
Operating Features  
16 “BATT” or  
is displayed when 2 “AAA” batteries  
are low and should be replaced.  
Nowthatyouarefamiliarwiththethermostatbuttonsanddisplay,read  
the following information to learn about the many features of the  
thermostat.  
Configuration Menu  
•฀ SIMULTANEOUS HEATING/COOLING PROGRAM STOR-  
AGE — When programming, you can enter both your heating  
and cooling programs at the same time. There is no need to  
reprogram the thermostat at the beginning of each season.  
Theconfigurationmenuallowsyoutosetcertainthermostatoperating  
characteristics to your system or personal requirements.  
Press RUN to make sure the thermostat is in the run program mode,  
thenpressPRGMandRUNatthesametimetoentertheconfiguration  
menu.The display will show the first item in the configuration menu.  
•฀ TEMPERATURE OVERRIDE — Press  
or  
until the  
display shows the temperature you want. The thermostat will  
override current programming and keep the room temperature  
attheselectedtemperatureuntilthenextprogramperiodbegins.  
Then the thermostat will automatically revert to the program.  
The configuration menu chart summarizes the configuration options.  
An explanation of each option follows.  
Press HOLD to change to the next menu item or press TIME to go  
backwards to the previous item in the menu. To exit the menu and  
return to the program operation, press RUN. If no keys are pressed  
within fifteen minutes, the thermostat will revert to normal operation.  
•฀ HOLD TEMPERATURE — The thermostat can hold any tem-  
peraturewithinitsrangeforanindefiniteperiod,withoutreverting  
to the programmed temperature.Press HOLD button.HOLD will  
be displayed.Then choose the desired temperature by pressing  
1. In the run mode, if the setpoint temperature is manually raised  
by 3°F (2°C) or more above the actual temperature with the TEM-  
PERATUREUPkey,andthefastsecondstagefeatureisenabled,  
FA on, the second stage will energize immediately. With FA off,  
second stage will not energize until the setpoint temperature is  
1°F or more above actual temperature for more than ten minutes.  
or  
. The thermostat will hold the room temperature  
at the selected setting until you press the RUN button to start  
program operation again.  
•฀ ENERGYMANAGEMENTRECOVERYEnergyManagement  
Recovery (EMR) causes the thermostat to start heating or cool-  
ing early to make the building temperature reach the program  
setpoint at the time you specify.Heating will start 5 minutes early  
for every 1° of temperature required to reach setpoint.  
2. Select Compressor Lockout CL OFF or ON – Selecting CL ON  
will cause the thermostat to wait 5 minutes before turning on the  
compressor if the heating and cooling system loses power. It will  
alsowait5minutesminimumbetweencoolingandheatingcycles.  
Thisisintendedtohelpprotectthecompressorfromshortcycling.  
Some newer compressors already have a time delay built in and  
do not require this feature. Your compressor manufacturer can  
tell you if the lockout feature is already present in their system.  
When the thermostat compressor time delay occurs it will flash  
the Snowflake and Flame Icons for about five minutes.  
Example: You select EMR and have your heating programmed  
to 65° at night and 70° at 7 AM.If the building temperature is 65°  
the difference between 65° and 70° is 5°.Allowing 5 minutes per  
degree the thermostat setpoint will change to 70° at 6:35 AM.  
Cooling allows more time per degree because it takes longer  
to reach temperature.  
•฀ °F/°C CONVERTIBILITY — The factory default setting is Fahr-  
enheit. Clipping W904 jumper on the circuit board (see fig. 1)  
will alter this feature to Celsius temperature setting.  
Configuration Menu  
Step  
1
Press Button(s)  
Displayed (Factory Default) Press  
or  
to select:  
COMMENTS  
PRGM  
and RUN  
FA  
(on)  
OFF  
Select Fast (on) or slow (off) Second Stage Heat  
CL  
(OFF)  
Select Compressor lockout OFF or ON  
ON  
HOLD*  
HOLD*  
2
3 LO TO  
3 HI  
0 HI  
(0)  
Select temperature display adjustment higher or lower  
3
dL  
(ON)  
Select display backlight OFF or ON  
Returns to normal operation  
OFF  
HOLD*  
RUN  
4**  
5
* Press HOLD to advance to next item or TIME to move backwards to previous item  
** Not available on earlier models  
5
GeneralDetails
NameWhite Rodgers 1F72 5 2 Day Programmable Thermostat Instructions
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.26 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

White Rodgers 1F72 5 2 Day Programmable Thermostat Instructions