HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
The device has implemented ZeroX technology.
This technology makes sure the relay switches at 0V when
turning on and off. With this technology the thermostat will
have a much longer lifetime.
it clicks into place. In order to get power metering values, the
load needs to be connected to both heating L + N.
A2
A2F
PWER
External room sensor
External room sensor + Floor sensor
Power regulator mode (no sensor used)
TECHNICAL DATA
HEATIT
PRODUCT
DOCUMENTS
Protocol
Rated voltage
Max load
Wi-Fi 2.4GHz/BLE
230VAC 50Hz
3600W 16A (resistive load)
Never change the front from one thermostat to another.
WIFI6
Quick Guide
Contactor recommended for loads above 13A
16A
<2W
The device can withstand a load of max. 16A/3600W at
230VAC. We recommend a contactor for loads above 13A.
ADD/REMOVE
NOTE: Some types of floor require that a floor sensor is
connected in order to limit the floor temperature to a maximum
of 27°C (check the manual from the floor manufacturer). When
the thermostat is used in (AF or A2F) the floor limiter FHI is
automatically set to 27°C. When using any other sensor type
(A, F or A2) the minimum and maximum limits are 5°C and 40°C
respectively.
Max current
Power consumption
Power regulator
Upon connecting the device to power, it will automatically
enter add mode for a duration of 60 minutes. During this time
the device can be added to the app without starting add mode
on the thermostat.
Time cycle 30 min.
Article no.
Doc. version
Doc. date
INSTALLATION DISCLAIMER
Ambient temperature 5°C to 40°C
Temperature range 5°C to 40°C
Storage temperature -30°C to 70°C
54 305 41
54 305 42
54 305 43
Installation must be done by a qualified electrician in
accordance with national building codes. Before installation,
disconnect the power to the device from the mains. During
installation of the device, power to the device must be
disconnected AT ALL TIMES!
2024-B
04.04.2024
To remove a device, find the device in the ”MyHeatit” App and
choose “Delete this device”. If the app is unavailable, or if the
thermostat is unreachable from the app, perform a ”Factory
Reset”.
Hysteresis
Humidity
Compatible with NTC-
sensor with values
Screw terminals
IP Code
0.3°C to 3.0°C (default 0.5°C)
10% to 85% RH
FACTORY RESET
Enter the menu by holding the center button for about 5
seconds, navigate in the menu with the ”+” button till you see
”FACT”. Press the center button until you see “-- --” blinking in
the display, then hold for about 5 seconds to perform a reset.
You may also initiate a reset by holding the right and center
buttons for 60 seconds.
6.8, 10, 12, 15, 22, 33, 47 or 100kΩ @ 25°C
Max. 2.5mm2 2Nm
IP21
QUICK START
Upon connecting the device to power, it will automatically
enter add mode for a duration of 60 minutes.
1. Switch off the mains voltage (disable the fuse).
2. Open the junction box.
3. Connect the wires according to the description in chapter
“Connections”. Optional: Connect external wired sensors.
4. After verifying the connections, switch on the mains voltage.
5. In the ”MyHeatit” App, choose ’Add Device’, enter your Wi-Fi
details, search for and select your device.
Method 1: Wi-Fi and Bluetooth
Add mode is indicated on the device by rotating LED segments
in the display. It indicates this for 90 seconds until a timeout
occurs, or until the device has been added to the network.
Add mode may also be cancelled by performing the same
procedure as for starting add mode.
Size (LxWxH)
84 x 84 x 45.5mm
Approvals
CE, Nemko
When either of these procedures has been performed, the
thermostat will perform a complete factory reset. The device
will display “RES” for 5 seconds while performing a factory reset.
When “RES” is no longer displayed, the thermostat has been
reset.
MAINTENANCE
The product is maintenance-free.
Indoor use only.
1. Hold the center button for 5 seconds.
White RAL 9003 White RAL 9010
Black matt
54 305 43
The display will show ”OFF”.
54 305 42
54 305 41
6. The thermostat will display “INCL” when the thermostat is
successfully added.
2. Press the ”+” button once to see “CON” in the display.
3. Start the configuration mode on the thermostat by holding
the center button for approximately 2 seconds.
4. In the ”MyHeatit” App, choose ’Add Device’. Choose Wi-Fi or
Bluetooth, and search for your device and select it.
ERROR CODES
Err
INTRODUCTION
NB! If adding/removing fails, Err (error) will appear in the display.
Adding fail
See Manual: Chapter “Add/remove”.
Internal error
Most probably a faulty unit. Contact support.
Wi-Fi error
Most probably a faulty unit. Contact support.
Internal error
Most probably a faulty unit. Contact support.
Floor sensor error
Heatit WiFi6 is an electronic thermostat designed for electrical
heating. The thermostat can be controlled using the ”MyHeatit”
App via Wi-Fi, Bluetooth (BLE), or by the buttons on the front of
the thermostat. The thermostat has a user friendly interface.
CONNECTIONS
Err1
Err2
Err3
Err4
Max tightening torque for terminal screws: 2Nm.
If the cable used has multiple strands, using a end sleeve is
advised. The product allows for wiring of cables with a cross
section of up to 1x2.5mm2.
The device is now ready for use with default settings.
GET THE MYHEATIT APP HERE
NB! When the device is removed from the ”MyHeatit” App, the
parameters are reset.
Heatit WiFi6 has 3 modes; Heat - Cool and Eco.
The thermostat fits in standard European junction boxes and
may be used with most System 55 frames. It has a sturdy metal
frame for secure fastening on the junction box. The thermostat
has a built-in room temperature sensor. Two additional external
temperature sensors may also be connected. The device has an
open API and supports Amazon Alexa and Google Home (open
API, Amazon Alexa and Google Home is pending).
To access the terminal screws, hold the sides of the display and
gently pull outwards to detach the front piece.
If inclusion fails, please perform a ”Factory Reset”.
You have chosen F, AF or A2F sensor mode without
having a floor sensor connected, or the sensor may
be damaged.
Method 2: QR Code
1. Hold the center button for 5 seconds. The display will show
“OFF”.
2. Press the ”+” button once to see “CON” in the display.
3. Start the add mode on the thermostat by holding the center
button for approximately 2 seconds.
4. In the ”MyHeatit” App, “Add Wi-Fi device” or “Add Bluetooth
device”.
5. Press the QR Code button in the bottom right and scan the
QR code on the device.
Err5
External sensor error
You have chosen A2 or A2F sensor mode without
having an external sensor connected, or the sensor
may be damaged.
The thermostat can communicate over a local API, where
the user can make integration with a local gateway, server,
controller that offers such a service.
Err6
Err7
Overheating
Contact your electrician.
Overload
Floor sensor
NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.
Contact your electrician.
The installer can configure and set up the system via Bluetooth.
After the system is set up, the installer can transfer the property
to the customer. The customer can then add the system to
their Wi-Fi network.
Default 10kΩ.
We develop and design our products according in accordance with our strict quality
requirements (ISO 9001) and environmental requirements (ISO 14001). All electrical
installations must be carried out by an authorized electrical installer. The product
must be installed in accordance with our installers manual and national building
codes. Any wrongful installation, misuse, damage of the product, is not covered
documents.heatit.com. Heatit Controls AB can not be held liable for any type of
errors or omittances in our product information. Product specifications may change
without further notice.
External sensor NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.
CHOICE OF SENSOR
DISPLAY ICONS
ICON DESCRIPTION
Default 10kΩ.
The thermostat has multiple sensors and sensor modes. This
lets you configure the thermostat to work correctly in most
installations. The sensors and modes may be selected from
either the local settings menu or via Parameter 2; ”Sensor mode
(“OPER”)”.
N
Power connection (Neutral) 230VAC.
Heating cable N connection.
Power connection (Live) 230VAC.
Heating cable L connection.
Heating N
L
Heating L
This icon will be displayed while the relay is on and
the thermostat is in either Heating or Eco mode.
Heatit WiFi6 has active power metering and it gives you real
time information about your power consumption. It also
allows you to set the power metering value manually in case of
connection with a contactor.
This icon will be displayed while the relay is on and
the thermostat is in Cooling mode.
INSTALLATION
Available sensor modes:
Position the thermostat and mount it into the junction box
using 2 screws. Position the thermostat front over the part
mounted in the junction box, then carefully press the front until
F
A
AF
Floor sensor
Internal room sensor
Internal room sensor + Floor sensor
This icon shows the current signal strength.
Org. doc. 02.04.2024
Heatit Controls AB
l
Läkarvägen 4, 454 31 BRASTAD, SWEDEN
| General | Details |
|---|---|
| Name | HEATIT 54 305 41 WiFi6 Thermostat Installation Guide |
| Make | HEATIT |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.79 MB |

heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual

HEATIT Z-TRM3 Thermostat User Guide

Heatit Z-TEMP2 Thermostat Installation Guide

heatit Z-TRM3 WiFi Thermostat Instruction Manual

HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual

4512673 Heatit ZM Thermostat 16A User Guide

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

HEATIT 54 304 59 DIN Smart Thermostat Installation Guide

HEATIT Z-TEMP3 Thermostat User Guide

heatit ET-7AW Touchscreen Programmable Thermostat User Manual

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide Overview
Summary of Contents
- Page 1: The device has implemented ZeroX technology, ensuring relay switches at 0V for longer thermostat lifetime. To obtain power metering values, the load must connect to both heating L + N. The device can withstand a maximum load of 16A/3600W at 230VAC. A contactor is recommended for loads above 13A. Installation must be performed by a qualified electrician according to national building codes. The thermostat has a built-in room temperature sensor and supports additional external temperature sensors. Heatit WiFi6 has three modes: Heat, Cool, and Eco. The product is maintenance-free and designed for indoor use only. The thermostat can communicate over a local API for integration with local gateways or servers. The installer can configure the system via Bluetooth before transferring it to the customer for Wi-Fi network addition.
- Page 2: Inkludering/ekskludering Noen gulvtyper krever at en gulvføler er tilkoblet for å begrense gulvtemperaturen til maksimalt 27°C. Produktet tåler en belastning på maks. 16A/3600W ved 230VAC. Når enheten kobles til strøm, vil den automatisk gå i inkluderingsmodus i 60 minutter. Produktet skal installeres av autorisert installatør i henhold til norske byggforskrifter. Enheten er nå klar til bruk med standardinnstillinger. Heatit WiFi6 er en elektronisk termostat designet for elektrisk gulvvarme. Termostaten styres gjennom MyHeatit-appen via Wi-Fi, Bluetooth (BLE) eller via knappene på fronten. Alle elektriske installasjoner skal utføres av en registrert installasjonsvirksomhet. Heatit WiFi6 har aktiv strømmåling som gir deg oversikt over forbruket i sanntid. Produktet har implementert ZeroX teknologi for lengre levetid på releet.