Home > HEATIT > HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

The device has implemented ZeroX technology.  
This technology makes sure the relay switches at 0V when  
turning on and off. With this technology the thermostat will  
have a much longer lifetime.  
it clicks into place. In order to get power metering values, the  
load needs to be connected to both heating L + N.  
A2  
A2F  
PWER  
External room sensor  
External room sensor + Floor sensor  
Power regulator mode (no sensor used)  
TECHNICAL DATA  
HEATIT  
PRODUCT  
DOCUMENTS  
Protocol  
Rated voltage  
Max load  
Wi-Fi 2.4GHz/BLE  
230VAC 50Hz  
3600W 16A (resistive load)  
Never change the front from one thermostat to another.  
WIFI6  
Quick Guide  
Contactor recommended for loads above 13A  
16A  
<2W  
The device can withstand a load of max. 16A/3600W at  
230VAC. We recommend a contactor for loads above 13A.  
ADD/REMOVE  
NOTE: Some types of floor require that a floor sensor is  
connected in order to limit the floor temperature to a maximum  
of 27°C (check the manual from the floor manufacturer). When  
the thermostat is used in (AF or A2F) the floor limiter FHI is  
automatically set to 27°C. When using any other sensor type  
(A, F or A2) the minimum and maximum limits are 5°C and 40°C  
respectively.  
Max current  
Power consumption  
Power regulator  
Upon connecting the device to power, it will automatically  
enter add mode for a duration of 60 minutes. During this time  
the device can be added to the app without starting add mode  
on the thermostat.  
Time cycle 30 min.  
Article no.  
Doc. version  
Doc. date  
INSTALLATION DISCLAIMER  
Ambient temperature 5°C to 40°C  
Temperature range 5°C to 40°C  
Storage temperature -30°C to 70°C  
54 305 41  
54 305 42  
54 305 43  
Installation must be done by a qualified electrician in  
accordance with national building codes. Before installation,  
disconnect the power to the device from the mains. During  
installation of the device, power to the device must be  
disconnected AT ALL TIMES!  
2024-B  
04.04.2024  
To remove a device, find the device in the ”MyHeatit” App and  
choose “Delete this device”. If the app is unavailable, or if the  
thermostat is unreachable from the app, perform a ”Factory  
Reset”.  
Hysteresis  
Humidity  
Compatible with NTC-  
sensor with values  
Screw terminals  
IP Code  
0.3°C to 3.0°C (default 0.5°C)  
10% to 85% RH  
FACTORY RESET  
Enter the menu by holding the center button for about 5  
seconds, navigate in the menu with the ”+” button till you see  
”FACT”. Press the center button until you see “-- --” blinking in  
the display, then hold for about 5 seconds to perform a reset.  
You may also initiate a reset by holding the right and center  
buttons for 60 seconds.  
6.8, 10, 12, 15, 22, 33, 47 or 100kΩ @ 25°C  
Max. 2.5mm2 2Nm  
IP21  
QUICK START  
Upon connecting the device to power, it will automatically  
enter add mode for a duration of 60 minutes.  
1. Switch off the mains voltage (disable the fuse).  
2. Open the junction box.  
3. Connect the wires according to the description in chapter  
“Connections”. Optional: Connect external wired sensors.  
4. After verifying the connections, switch on the mains voltage.  
5. In the ”MyHeatit” App, choose ’Add Device’, enter your Wi-Fi  
details, search for and select your device.  
Method 1: Wi-Fi and Bluetooth  
Add mode is indicated on the device by rotating LED segments  
in the display. It indicates this for 90 seconds until a timeout  
occurs, or until the device has been added to the network.  
Add mode may also be cancelled by performing the same  
procedure as for starting add mode.  
Size (LxWxH)  
84 x 84 x 45.5mm  
Approvals  
CE, Nemko  
When either of these procedures has been performed, the  
thermostat will perform a complete factory reset. The device  
will display “RES” for 5 seconds while performing a factory reset.  
When “RES” is no longer displayed, the thermostat has been  
reset.  
MAINTENANCE  
The product is maintenance-free.  
Indoor use only.  
1. Hold the center button for 5 seconds.  
White RAL 9003 White RAL 9010  
Black matt  
54 305 43  
The display will show ”OFF”.  
54 305 42  
54 305 41  
6. The thermostat will display “INCL” when the thermostat is  
successfully added.  
2. Press the ”+” button once to see “CON” in the display.  
3. Start the configuration mode on the thermostat by holding  
the center button for approximately 2 seconds.  
4. In the ”MyHeatit” App, choose ’Add Device’. Choose Wi-Fi or  
Bluetooth, and search for your device and select it.  
ERROR CODES  
Err  
INTRODUCTION  
NB! If adding/removing fails, Err (error) will appear in the display.  
Adding fail  
See Manual: Chapter “Add/remove”.  
Internal error  
Most probably a faulty unit. Contact support.  
Wi-Fi error  
Most probably a faulty unit. Contact support.  
Internal error  
Most probably a faulty unit. Contact support.  
Floor sensor error  
Heatit WiFi6 is an electronic thermostat designed for electrical  
heating. The thermostat can be controlled using the ”MyHeatit”  
App via Wi-Fi, Bluetooth (BLE), or by the buttons on the front of  
the thermostat. The thermostat has a user friendly interface.  
CONNECTIONS  
Err1  
Err2  
Err3  
Err4  
Max tightening torque for terminal screws: 2Nm.  
If the cable used has multiple strands, using a end sleeve is  
advised. The product allows for wiring of cables with a cross  
section of up to 1x2.5mm2.  
The device is now ready for use with default settings.  
GET THE MYHEATIT APP HERE  
NB! When the device is removed from the ”MyHeatit” App, the  
parameters are reset.  
Heatit WiFi6 has 3 modes; Heat - Cool and Eco.  
The thermostat fits in standard European junction boxes and  
may be used with most System 55 frames. It has a sturdy metal  
frame for secure fastening on the junction box. The thermostat  
has a built-in room temperature sensor. Two additional external  
temperature sensors may also be connected. The device has an  
open API and supports Amazon Alexa and Google Home (open  
API, Amazon Alexa and Google Home is pending).  
To access the terminal screws, hold the sides of the display and  
gently pull outwards to detach the front piece.  
If inclusion fails, please perform a ”Factory Reset”.  
You have chosen F, AF or A2F sensor mode without  
having a floor sensor connected, or the sensor may  
be damaged.  
Method 2: QR Code  
1. Hold the center button for 5 seconds. The display will show  
“OFF”.  
2. Press the ”+” button once to see “CON” in the display.  
3. Start the add mode on the thermostat by holding the center  
button for approximately 2 seconds.  
4. In the ”MyHeatit” App, “Add Wi-Fi device” or “Add Bluetooth  
device”.  
5. Press the QR Code button in the bottom right and scan the  
QR code on the device.  
Err5  
External sensor error  
You have chosen A2 or A2F sensor mode without  
having an external sensor connected, or the sensor  
may be damaged.  
The thermostat can communicate over a local API, where  
the user can make integration with a local gateway, server,  
controller that offers such a service.  
Err6  
Err7  
Overheating  
Contact your electrician.  
Overload  
Floor sensor  
NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.  
Contact your electrician.  
The installer can configure and set up the system via Bluetooth.  
After the system is set up, the installer can transfer the property  
to the customer. The customer can then add the system to  
their Wi-Fi network.  
Default 10kΩ.  
We develop and design our products according in accordance with our strict quality  
requirements (ISO 9001) and environmental requirements (ISO 14001). All electrical  
installations must be carried out by an authorized electrical installer. The product  
must be installed in accordance with our installers manual and national building  
codes. Any wrongful installation, misuse, damage of the product, is not covered  
documents.heatit.com. Heatit Controls AB can not be held liable for any type of  
errors or omittances in our product information. Product specifications may change  
without further notice.  
External sensor NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.  
CHOICE OF SENSOR  
DISPLAY ICONS  
ICON DESCRIPTION  
Default 10kΩ.  
The thermostat has multiple sensors and sensor modes. This  
lets you configure the thermostat to work correctly in most  
installations. The sensors and modes may be selected from  
either the local settings menu or via Parameter 2; ”Sensor mode  
(“OPER”)”.  
N
Power connection (Neutral) 230VAC.  
Heating cable N connection.  
Power connection (Live) 230VAC.  
Heating cable L connection.  
Heating N  
L
Heating L  
This icon will be displayed while the relay is on and  
the thermostat is in either Heating or Eco mode.  
Heatit WiFi6 has active power metering and it gives you real  
time information about your power consumption. It also  
allows you to set the power metering value manually in case of  
connection with a contactor.  
This icon will be displayed while the relay is on and  
the thermostat is in Cooling mode.  
INSTALLATION  
Available sensor modes:  
Position the thermostat and mount it into the junction box  
using 2 screws. Position the thermostat front over the part  
mounted in the junction box, then carefully press the front until  
F
A
AF  
Floor sensor  
Internal room sensor  
Internal room sensor + Floor sensor  
This icon shows the current signal strength.  
Org. doc. 02.04.2024  
Heatit Controls AB  
l
Läkarvägen 4, 454 31 BRASTAD, SWEDEN  
Phone: +47 61 18 77 77 l post@heatit.com – www.heatit.com  
GeneralDetails
NameHEATIT 54 305 41 WiFi6 Thermostat Installation Guide
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.79 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
Get the free PDF manual for the HEATIT 54 305 41 WiFi6 Thermostat Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide Overview

Summary of Contents

  • Page 1: The device has implemented ZeroX technology, ensuring relay switches at 0V for longer thermostat lifetime. To obtain power metering values, the load must connect to both heating L + N. The device can withstand a maximum load of 16A/3600W at 230VAC. A contactor is recommended for loads above 13A. Installation must be performed by a qualified electrician according to national building codes. The thermostat has a built-in room temperature sensor and supports additional external temperature sensors. Heatit WiFi6 has three modes: Heat, Cool, and Eco. The product is maintenance-free and designed for indoor use only. The thermostat can communicate over a local API for integration with local gateways or servers. The installer can configure the system via Bluetooth before transferring it to the customer for Wi-Fi network addition.
  • Page 2: Inkludering/ekskludering Noen gulvtyper krever at en gulvføler er tilkoblet for å begrense gulvtemperaturen til maksimalt 27°C. Produktet tåler en belastning på maks. 16A/3600W ved 230VAC. Når enheten kobles til strøm, vil den automatisk gå i inkluderingsmodus i 60 minutter. Produktet skal installeres av autorisert installatør i henhold til norske byggforskrifter. Enheten er nå klar til bruk med standardinnstillinger. Heatit WiFi6 er en elektronisk termostat designet for elektrisk gulvvarme. Termostaten styres gjennom MyHeatit-appen via Wi-Fi, Bluetooth (BLE) eller via knappene på fronten. Alle elektriske installasjoner skal utføres av en registrert installasjonsvirksomhet. Heatit WiFi6 har aktiv strømmåling som gir deg oversikt over forbruket i sanntid. Produktet har implementert ZeroX teknologi for lengre levetid på releet.