Home > HEATIT > HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

STATEMENT REGARDING PRODUCTS FROM MULTIPLE  
MANUFACTURERS  
Please read this before installation  
5. Set the primary controller in add mode (security/non  
security).  
FACTORY RESET  
TECHNICAL DATA  
Enter the menu by holding the Center button for about 5  
seconds, navigate in the menu with the ”+” button til you see  
FACT. Press the Center button until you see “-- --” blinking in  
the display, then hold for about 5 seconds to perform a reset.  
You may also initiate a reset by holding the Right and Center  
buttons for 60 seconds.  
HEATIT  
Protocol  
Chip  
Z-Wave Plus, 868.4MHz  
Z-Wave 800 chip  
230VAC 50Hz  
3600W 16A (resistive load)  
Contactor recommended for  
loads above 13A  
16A  
6. Hold the Center button until “OFF” is shown in the display  
(approx. 5 seconds).  
This device may be used with all devices certified with the  
Z-Wave Plus™ certificate and should be compatible with  
such devices produced by any manufacturer. Every primary  
controller is different depending on the manufacturer, their  
target audience and intended use/application. Please review  
the functionalities implemented by the primary controller you  
intend to use with our Z-Wave Plus certified device to ensure  
that it provides the necessary controls to take full advantage of  
our product’s capabilities.  
Rated voltage  
Max load  
Z-TRM6  
Quick Guide  
7. Press the ”+” button once to reach “CON”, and hold until the  
display shows a rotating light pattern.  
TO PRODUCT  
DOCUMENTS  
8. The thermostat will display “INCL” when the thermostat is  
successfully added. NB! If adding/removing fails, Err (error)  
will appear.  
Max current  
Power consumption  
Power regulator  
Article no.  
Doc. version  
Doc. date  
When either of these procedures has been performed, the  
thermostat will perform a complete factory reset. The device  
will display “RES” for 5 seconds while performing a factory reset.  
When “RES” is no longer displayed, the thermostat has been  
reset.  
<2W  
54 305 66  
54 305 68  
2023-A  
01.07.2023  
Time cycle 0 to 30 min.  
Ambient temperature 5°C to 40°C  
Temperature range 5°C to 40°C  
Storage temperature -30°C to 70°C  
Hysteresis  
Humidity  
ADD/REMOVE  
The primary controller/gateway has a mode for adding or  
removing devices. Please refer to your primary controller  
manual on how to set the primary controller in add/remove  
mode. The device may only be added or removed from the  
network if the primary controller is in add/remove mode. When  
the device is removed from the network, it will NOT revert to  
factory settings.  
INSTALLATION  
0.3°C to 3.0°C (default 0.5°C)  
10% to 85% RH  
Please use this procedure only when the network primary  
controller is missing or otherwise inoperable.  
Installation must be done by a qualified electrician in  
accordance with national building codes. Before installation,  
disconnect the power to the device from the mains. During  
installation of the device, power to the device must be  
disconnected AT ALL TIMES!  
Compatible with NTC-  
sensor with values  
Range RF  
6.8, 10, 12, 15, 22, 33, 47 or 100k@ 25°C  
Min. 40 meter  
Max. 2.5mm2 2Nm  
IP21  
CHOICE OF SENSOR  
The thermostat has multiple sensors and sensor modes. This  
lets you configure the thermostat to work correctly in most  
installations.  
Screw terminals  
IP Code  
Size (LxWxH)  
CONNECTIONS  
Max tightening torque terminal screws: 2Nm.  
84 x 84 x 45.5mm  
An always listening node must be powered continuously and  
reside in a fixed position in the installation to secure the routing  
table. Adding the device within a 2 meter range from the  
gateway can minimize faults during the Interview process.  
Available temperature sensors:  
Approvals  
Z-Wave Plus v2, CE, Nemko  
White RAL 9003  
54 305 66  
Black matt  
54 305 68  
To access the terminal screws, hold the sides of the display and  
gently pull outwards to detach the front piece.  
F
Floor sensor  
MAINTENANCE  
A
Internal room sensor  
There are two ways to add the device to a Z-Wave network.  
AF  
A2  
A2F  
Internal room sensor + Floor sensor  
External room sensor  
The product is maintenance-free.  
Indoor use only.  
INTRODUCTION  
Standard (Manual)  
Heatit Z-TRM6 is an electronic thermostat designed for  
electrical heating. The thermostat can be controlled through  
your Z-Wave™ network or via the buttons on the front. The  
thermostat has a user friendly interface.  
External room sensor + Floor sensor  
Add/remove mode is indicated on the device by rotating  
LED segments on the display. It indicates this for 90 seconds  
until a timeout occurs, or until the device has been added to/  
removed from the network. Configuration mode can also be  
cancelled by performing the same procedure used for starting  
Configuration mode.  
45.5mm  
PWER Power regulator mode (no sensor used)  
22mm 23.5mm  
50mm  
NOTE: Some types of floor require that a floor sensor is  
connected in order to limit the floor temperature to a maximum  
of 27°C (check the manual from the floor manufacturer). When  
the thermostat is used in AF or A2F the floor limiter FHI is  
automatically set to 27°C. When using any other sensor type  
(A, F or A2) the minimum and maximum limits are 5°C and 40°C  
respectively.  
Heatit Z-TRM6 has 3 modes; Heat - Cool and Eco.  
The thermostat fits in standard European junction boxes and  
may be used with most System 55 frames. It has a sturdy metal  
frame for secure fastening on the junction box. The thermostat  
has one built-in room temperature sensor. Two additional  
external temperature sensors may also be connected.  
1. Hold the Center button for 5 seconds.  
The display will show “OFF”.  
Floor sensor  
NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100k.  
Default 10k.  
2. Press the ”+” button once to see “CON” in the display.  
3. Start the add/remove device process in your primary  
controller.  
External sensor NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100k.  
DISPLAY ICONS  
Default 10k.  
Heatit Z-TRM6 has active power metering and it gives you real  
time information about your power consumption. It also allows  
you to set the power metering value manually in case of  
connection with a contactor.  
N
Power connection (Neutral) 230VAC.  
Heating cable N connection.  
ICON  
DESCRIPTION  
4. Start the configuration mode on the thermostat by holding  
the Center button for approximately 2 seconds.  
Heating N  
L
This icon will be displayed while the relay is on and  
the thermostat is in either Heating or Eco mode.  
Power connection (Live) 230VAC.  
Heating cable L connection.  
Heating L  
The device is now ready for use with default settings.  
This icon will be displayed while the relay is on and  
the thermostat is in Cooling mode.  
The thermostat can be set up with multiple associations  
and can be used as a master thermostat. It can also control  
external relays and wall plugs.  
Next, position the thermostat and mount it into the junction  
box using 2 screws. Position the thermostat front over the part  
mounted in the junction box, then carefully press the front until  
it clicks into place. In order to get power metering values, the  
load needs to be connected to both heating L + N.  
NB! When the device is removed from the gateway, the  
parameters are not reset. To reset the parameters, see  
”Factory reset”.  
This icon shows the current signal strength.  
We develop and design our products according in accordance with our strict quality  
requirements (ISO 9001) and environmental requirements (ISO 14001). All electrical  
installations must be carried out by an authorized electrical installer. The product  
must be installed in accordance with our installers manual and national building  
codes. Any wrongful installation, misuse, damage of the product, is not covered  
documents.heatit.com. Heatit Controls AB can not be held liable for any type of  
errors or omittances in our product information. Product specifications may change  
without further notice.  
The thermostat can withstand a load of max. 16A/3600W at  
230VAC. We recommend a contactor for loads above 13A.  
If inclusion fails, please perform a ”remove device” process and  
try again. If inclusion fails again, please see “Factory reset”.  
QUICK START  
1. Switch off the mains voltage (disable the fuse).  
2. Open the junction box.  
SmartStart (Automatic)  
SmartStart enabled products may be added to a Z-Wave  
network by scanning the Z-Wave QR-Code on the product  
if your primary controller supports SmartStart inclusion. No  
further action is required and the SmartStart product will be  
added automatically after being powered on within range of the  
primary controller.  
3. Connect the wires according to the description above  
Optional: Connect external wired sensors.  
4. After verifying the connections, switch on the mains voltage.  
Org. doc. 01.07.2023  
Heatit Controls AB  
l
Läkarvägen 4, 454 31 BRASTAD, SWEDEN  
Phone: +47 61 18 77 77 l post@heatit.com – www.heatit.com  
GeneralDetails
NameHEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.27 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
Get the free PDF manual for the HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide Overview

Summary of Contents

  • Page 1: statement regarding products from multiple manufacturers please read this before installation set the primary controller in add mode (security/non security) factory reset technical data the device may be used with all devices certified with the Z-Wave Plus™ certificate and should be compatible with such devices produced by any manufacturer. installation must be done by a qualified electrician in accordance with national building codes. the thermostat has multiple sensors and sensor modes. the product is maintenance-free. the thermostat can withstand a load of max. 16A/3600W at 230VAC.
  • Page 2: Erklæring vedrørende produkter fra ulike produsenter Les dette før installasjon Denne enheten kan brukes sammen med andre enheter sertifisert med Z-Wave Plus™-sertifikatet. Hver gateway er forskjellig avhengig av produsent, målgruppe og tiltenkt bruk/applikasjon. Hold midtknappen inne til du ser OFF i displayet (ca. 5 sek.). Trykk på + knappen. CON vises i displayet. Gå inn i menyen ved å holde midtknappen inne i ca. 5 sekunder. Displayet vil vise INCL når termostaten har blitt inkludert. Når en av disse prosedyrene er utført, vil termostaten utføre en fullstendig tilbakestilling til fabrikkinnstillinger. Produktet skal installeres av autorisert installatør i henhold til norske byggforskrifter. Heatit Z-TRM6 er en elektronisk termostat designet for elektrisk gulvvarme.