Table 6: Parameter C23 - Output 8 function.  
VALUE  
DESCRIPTION  
No function  
0
1
Fan logic; relay closed when the proportional fan is on.  
Inverted fan logic; relay closed when the proportional fan is off.  
Valve logic; relay closed when the valve is open.  
Inverted valve logic; relay closed when the valve is closed.  
ON/OFF logic; the output is active when the thermostat is on.  
Inverted ON/OFF logic; the output is active when the thermostat is off.  
Economy logic; the output is active when the thermostat is in economy mode or off.  
2
3
4
5
6
7
Inverted Economy logic; the output is active when the thermostat is on and NOT in economy  
mode.  
8
9
Summer/Winter logic; the output is active when the thermostat is in heating (winter) mode.  
Inverted Summer/Winter logic; the output is active when the thermostat is in cooling (sum-  
mer) mode.  
10  
Duplicate input 3; this output is active when input 3 is closed.  
Inverted duplicate input 3; this output is active when input 3 is open.  
Duplicate input 4; this output is active when input 4 is closed.  
Inverted duplicate input 4; this output is active when input 4 is open.  
Duplicate input 16; this output is active when input 16 is closed.  
Inverted duplicate input 16; this output is active when input 16 is open.  
11  
12  
13  
14  
15  
16  