C22: If the buttons are not pressed for a few seconds, the thermostat reverts to displaying
the room temperature.
When this parameter is set to 1, the thermostat displays the set-point temperature instead of the
room temperature.
C23: This parameter is used to inform the thermostat which function should be implemented
on output 8.
Table 6 lists the functions that can be implemented.
See section “Output 8” for more information.
CORRECT ROOM TEMPERATURE MEASUREMENT
To ensure the system measures the room temperature correctly, it is necessary to take the following
into account.
-
To ensure the temperature is acquired correctly, the thermostat should be installed where it is not
exposed to from heat sources, air flows or cold walls (thermal bridges). When using the remote
temperature probe in conjunction with the thermostat, this applies to the probe rather than the
thermostat itself.
-
When using a remote temperature probe, avoid routing the signal wires and power (mains) ca-
bles via the same conduit as this could compromise the accuracy of the temperature readings.
If necessary, use bipolar screened cable, connecting the screen to earth on the thermostat only
(terminal 14). The cable should have a minimum cross section of 1.5 mm2 and not exceed 15 m
in length.
-
-
During normal operation with the internal sensor, the thermostat conditions the acquired signal
by means of a special algorithm that has been designed to compensate for the heat generated
by its internal components. For this reason, the temperature value displayed when the device is
switched on may be lower than the real temperature. This effect is entirely normal and disappears
completely within a few minutes.
In the thermostat outputs are used to drive large loads (where the current is close to the maximum
rated value) the heat generated by the internal components may increase. This temperature
increase may also affect the acquired room temperature value, if measured using the internal
probe. This problem is not present when using the remote temperature probe.
If the acquired room temperature reading is considered unsatisfactory for any reason, it may be
corrected by modifying parameter P12.
-
-
When the thermostat is connected to a 230 V~power supply, it is essential that the live and
neutral (L + N) are respected when making the electrical connections.
Table 1: Main configuration parameters
DFLT PAR. DESCRIPTION
PERMITTED VALUES
System type
2
3
0
1
Heatingele- Integrated
ment
2-pipe sys- 4-pipe sys-
tem
-
-
0
0
P01
heating el-
ement
tem
Select summer/
winter
0
1
2
Manual
Automatic
-
P02
Centralised
IT - 24