Home > Roth > Roth Minishunt Plus Thermostat and Capillary Sensor Installation Guide

Roth Minishunt Plus Thermostat and Capillary Sensor Installation Guide

Roth Minishunt  
Installation  
Living full of energy  
1/8  
GeneralDetails
NameRoth Minishunt Plus Thermostat and Capillary Sensor Installation Guide
MakeRoth
LanguageEnglish
FiletypePDF (Download)
File size1.15 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Roth Basicline 230T Programmable Clock Thermostat Instruction Manual
Roth Basicline 230T Programmable Clock Thermostat Instruction Manual
Roth Basicline H 230V Room Thermostat Instructions
Roth Basicline H 230V Room Thermostat Instructions
Roth Minishunt Room Thermostat Installation Guide
Roth Minishunt Room Thermostat Installation Guide
Roth Touchline SL Standard Room Thermostat Installation Guide
Roth Touchline SL Standard Room Thermostat Installation Guide
Roth Minishunt Plus Wireless Room Thermostat Installation Guide
Roth Minishunt Plus Wireless Room Thermostat Installation Guide
Roth VVS-nr. 466397.058 Softline Standard Room Thermostat Instruction Manual
Roth VVS-nr. 466397.058 Softline Standard Room Thermostat Instruction Manual
Roth SL Car Air Conditioner Thermostat Instructions
Roth SL Car Air Conditioner Thermostat Instructions
Roth Touchline SL Plus Room Thermostat Instruction Manual
Roth Touchline SL Plus Room Thermostat Instruction Manual
Roth Basicline Wired Thermostat Installation Guide
Roth Basicline Wired Thermostat Installation Guide
Roth Touchline PL Wireless Room Thermostat Installation Guide
Roth Touchline PL Wireless Room Thermostat Installation Guide

Roth Minishunt Plus Thermostat and Capillary Sensor Installation Guide
Get the free PDF manual for the Roth Minishunt Plus Thermostat and Capillary Sensor Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Roth Minishunt Plus Thermostat and Capillary Sensor Installation Guide Overview

Summary of Contents

  • Page 1: Roth Minishunt Installation Living full of energy
  • Page 2: Roth Minishunt is designed for supplying one or two underfloor heating circuits in a room. The shunt can be connected out in the installation like a radiator and can be supplied with a Duo distributor for connecting two circuits. It is suitable for both 1- and 2-pipe systems and has a temperature limitation of 45°C. For installation instructions for wireless control, see separate instructions. The components of Roth Minishunt include a valve for the thermostat or actuator, a circulation pump, an air vent, and primary and secondary flow and return connections. When installing two circuits, they should always be of equal length.
  • Page 3: Installation requirements for Roth Minishunt include the following points: Minishunt must be installed in a horizontal position. Ensure a differential pressure of at least 15 kPa and a maximum of 50 kPa. The water temperature on the supply side should be at least 15°C higher than the floor heating circuit. Always flush the existing installation before installing the minishunt. Joints in the heating system should be visible or accessible. When installing in built-in spaces or cabinets, they must have a waterproof base of at least 50mm, a service hatch, and indication for quick leak detection. The service hatch should not be placed in wet zone 1.
  • Page 4: Installation Roth Minishunt Monter Minishunten på egnet væg. Pumpen kan give anledning til en smule støj, derfor anbefales det at montere shunten et sted, hvor det ikke vil genere. Udluft og foretag trykprøvning i henhold til branchereglerne. Vandpåfyldning, gennemskylning og udluftning optimeres ved at lukke afspærringsventilen. Husk at åbne igen inden idriftsættelse. Indstil mellem 1 - og 2 –strengs systemer. Indstil fremløbstemperatur. Monter det termostatiske følerelement eller termomotoren på ventilen. Føler eller termostat placeres ca. 1,7 m over gulv på en indervæg et repræsentativt sted. Indstil pumpen til konstanttryk. Normalt vil en indstilling som vist i billede 6E være tilstrækkelig for at opnå optimal komfort.
  • Page 5: Installation Roth Minishunt Signaldisplay LED lyser grønt ved normal drift LED lyser/blinker i tilfælde af fejl Visning af den valgte pumpedrift, vælg konstant pumpetryk Visning av valgt reguleringsmodus Δp-v, Δp-c og konstant hastighet Visning av valgt pumpekurve (I, II, III) i reguleringsmodus Kombinasjoner av LED-indikatorer under pumpeventilasjonsfunksjonen Ikke lys i LED = ikke strøm Ingen lys i LED = Ingen strøm
  • Page 6: Installation of minishunt for 1- or 2-pipe systems. Factory setting is for 2-pipe systems. Primary temperature should be at normal levels (55 - 60°C). Floor temperature should be approximately 20°C. Wait for 10 minutes. Supply temperature should be 30 - 35°C for concrete floors and 40 - 45°C for lighter floor constructions. Check the supply temperature on the floor heating circuit. Adjust the water flow on the primary side if the temperature is too high or low. Use the included key to adjust; turning clockwise reduces the temperature. By-pass valve settings vary for 1-pipe and 2-pipe systems.
  • Page 7: Tekniske data Anvendelsesområde Roth Minishunt m. trådløs regulering Maks. drifttryk Driftstemperatur Pumpe Tilslutning på primærside Materiale Maks. 80°C på anlægssiden Maks. 45°C på gulvvarmesiden
  • Page 8: Page 8