Installer Setting - E.S.P. Function  
This function determines the fan speed strength setting for each level (low, med, high).  
• If you set ESP incorrectly, the air conditioner may malfunction.  
• This setting must be carried out by a certificated-technician.  
Press the  
seconds to enter Thermostat  
installer setup mode.  
- If pressed for a shorter time, it  
enters into user setup mode.  
button for 3  
1
2
If entering into ESP setup mode by using  
button, it indicates as the picture  
below.  
ESP step  
Function Code  
ESP value  
Select ESP fan step by pressing  
buttons. (01: very low, 02: low,  
03: medium, 04: high, 05: very high)  
3
Function code,  
ESP code  
ESP value  
Move to ESP value setting by pressing  
button.  
(000 is the factory  
4
5
default setting.)  
Press  
buttons to setup ESP value.  
(It is possible to setup ESP  
value from 1 to 255, and 1 is  
the smallest and 255 is the  
largest).)  
• ESP settings vary between different product types.  