ROOM THERMOSTAT PLACEMENT  
ROOM THERMOSTAT WIRING DIAGRAM  
ENGLISH  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to  
heating/cooling units such as radiator, stove and spots which get  
direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find  
the most convenientspot.  
HEATING/COOLING UNIT  
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
MITRA 250S USER MANUAL  
GENERAL SPECIFICATIONS  
NO COM  
min. 20 cm  
DIGITAL ROOM THERMOSTAT  
MITRA 250S is a wired room thermostat. The user can adjust the  
room temperature with the required temperature and get more  
comfortable and economic heating/cooling.  
Warning!  
Operations within the heating  
/
cooling unit or the electrical  
installation must be carriedout byprofessionally qualified persons.  
PreciseTemperatureMeasurement  
Heating calibration  
ON/OFFControl  
Wired Connection  
TPIAlgorithm  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You may need to calibrate your Room Thermostat if you  
would like to get the same temperature values with other  
thermometersin yourliving space.  
Heating/Cooling Modes  
MITRA 250S  
USER MANUAL  
MITRA 250S AND EQUIPMENTS  
MITRA 250S  
Room Thermostat  
Alkaline  
Battery  
Dowels and  
Screws  
While your device is turned off, press and hold the button for 3  
seconds.  
Press the button until the “  
” menu appers. In order to see the  
desired temperature, set the temperature difference by turning the  
button to right or left. This valuecan be arranged between “-8oC" and  
“+8oC".  
BATTERY PLACEMENT  
Before starting, power off the device connected to the Room  
Thermostatand makesurethattheenergy is cutoff.  
To save the settings and exit, press the "On/Off" button until the  
deviceturns off.  
Note:Recommended tempreturecalibration is “0.0oC”.  
TECHNICAL DATA  
Dimensions  
85mm / 125mm / 24mm  
3V DC (2 x AAA alkaline battery)  
2A/30VDC (Resistive load)  
0.5A/125VAC (Resistive load)  
0.1oC  
Operating Current  
Relay NO Switching Current  
ROOM THERMOSTAT HEATING / COOLING MODES  
Your Room Thermostat has heating and cooling modes. In order to  
switcheasilybetweenheating and cooling modes:  
While your device is turned off, press and hold the button for 3  
seconds.  
Temperature Measurement  
Accuracy  
Operating Temperature Range  
Battery Life  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Pressthe button until the “  
” menu appears.  
” (heating) and “  
Operating Temperature  
Storage Temperature  
You can switch between “  
” (cooling) modes  
” menu.  
byturning the button to right or leftin the “  
To save the settings and exit, press the button until the device turns  
off.  
ROOM THERMOSTAT  
The settings you have made have been saved. Once you turned on  
yourdevice, itwilloperatewiththe changed settings.  
1
2
As shown in the picture above, press the screwdriver forward from the  
space shown, bend the tabs and separate the front cover. Insert 2 new  
AAA alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the  
front part of your Room Thermostat to the back and squeeze it  
towards theback.  
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings.  
This operation resets the calibration setting and heating/coling  
modes to factory setting. To reset your Room Thermostat to factory  
setting:  
3
4
5
6
Low Battery Warning: When the “ ” icon appears on the screen, it  
means “low battery warning”. It is recommended to replace the  
batterieswhen this warning appears.  
While your device is turned off, press and hold the button for 3  
seconds.  
1
2
3
Battery Indicator  
Room Temperature  
Set Temperature  
Cooling Indicator  
Pressthebutton until the“  
While in the “ “ menu, turn the button to right or left in order to  
select“ “ option and pressthebutton.  
” menu appears.  
Warning: When the product is not used for a long period (more than 15  
days), remove the batteries. Otherwise, malfunctions that may occur  
would beoutof warranty.  
Your devicewillbe turned off and resetto factory settings.  
Pleasethrowyour dead batteries into thewastebin forbatteries.  
- If the Cooling Indicator is blinking, the cooling unit is  
4
working.  
- If the Cooling Indicator is steady, the cooling unit is not  
working.  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is  
working.  
5
6
- If the Heating Indicator is steady, the heating unit is not  
working.  
ON/OFF and Temperature Setting Button  
generallife.com.tr  
2
1
3
GeneralDetails
NameGENERAL LIFE MITRA 250S Wired Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.04 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with air circulation or close to heating/cooling units should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. MITRA 250S is a wired room thermostat that allows users to adjust room temperature for comfortable and economic heating/cooling. Operations within the heating/cooling unit or electrical installation must be carried out by professionally qualified persons. Temperature sensors in room thermostats are highly sensitive and may require calibration for accurate readings. Your room thermostat has heating and cooling modes that can be switched easily. You can reset your room thermostat to its default factory settings, which will reset calibration and heating/cooling modes. When the low battery icon appears, it is recommended to replace the batteries. If the cooling or heating indicator is blinking, it means the respective unit is working.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. If the placement of the TPI Room Thermostats is changed or if they are de-energized, the learning process will restart and should be considered as taking 7 days. The TPI algorithm predicts temperature changes and controls the heating/cooling unit to maintain the set temperature with minimal deviations. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs covered by the warranty are conducted at the company factory, with transportation costs borne by the customer for on-site services. Malfunctions caused by customer misuse are not covered by the warranty, and damages from other brands without manufacturer approval are also excluded. The warranty document must be retained by the customer, and a replacement will not be issued if lost. The product is compatible with heating/cooling units that have on-off connections. The warranty period can be extended by the time spent on repairs if they occur within the warranty period. The manufacturer reserves the right to change product specifications and user manuals.