Home > GENERAL LIFE > GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual
GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual
ROOM THERMOSTAT PLACEMENT
ROOM THERMOSTAT WIRING DIAGRAM
ENGLISH
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to
heating/cooling units such as radiator, stove and spots which get
direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find
the most convenientspot.
HEATING/COOLING UNIT
DIGITAL ROOM THERMOSTAT
generallife.com.tr
MITRA 250S USER MANUAL
GENERAL SPECIFICATIONS
NO COM
min. 20 cm
DIGITAL ROOM THERMOSTAT
MITRA 250S is a wired room thermostat. The user can adjust the
room temperature with the required temperature and get more
comfortable and economic heating/cooling.
Warning!
Operations within the heating
/
cooling unit or the electrical
installation must be carriedout byprofessionally qualified persons.
PreciseTemperatureMeasurement
Heating calibration
ON/OFFControl
Wired Connection
TPIAlgorithm
ROOM THERMOSTATTEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You may need to calibrate your Room Thermostat if you
would like to get the same temperature values with other
thermometersin yourliving space.
Heating/Cooling Modes
MITRA 250S
USER MANUAL
MITRA 250S AND EQUIPMENTS
MITRA 250S
Room Thermostat
Alkaline
Battery
Dowels and
Screws
While your device is turned off, press and hold the button for 3
seconds.
Press the button until the “
” menu appers. In order to see the
desired temperature, set the temperature difference by turning the
button to right or left. This valuecan be arranged between “-8oC" and
“+8oC".
BATTERY PLACEMENT
Before starting, power off the device connected to the Room
Thermostatand makesurethattheenergy is cutoff.
To save the settings and exit, press the "On/Off" button until the
deviceturns off.
Note:Recommended tempreturecalibration is “0.0oC”.
TECHNICAL DATA
Dimensions
85mm / 125mm / 24mm
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
0.1oC
Operating Current
Relay NO Switching Current
ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to
switcheasilybetweenheating and cooling modes:
While your device is turned off, press and hold the button for 3
seconds.
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Pressthe button until the “
” menu appears.
” (heating) and “
Operating Temperature
Storage Temperature
You can switch between “
” (cooling) modes
” menu.
byturning the button to right or leftin the “
To save the settings and exit, press the button until the device turns
off.
ROOM THERMOSTAT
The settings you have made have been saved. Once you turned on
yourdevice, itwilloperatewiththe changed settings.
1
2
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards theback.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings.
This operation resets the calibration setting and heating/coling
modes to factory setting. To reset your Room Thermostat to factory
setting:
3
4
5
6
Low Battery Warning: When the “ ” icon appears on the screen, it
means “low battery warning”. It is recommended to replace the
batterieswhen this warning appears.
While your device is turned off, press and hold the button for 3
seconds.
1
2
3
Battery Indicator
Room Temperature
Set Temperature
Cooling Indicator
Pressthebutton until the“
While in the “ “ menu, turn the button to right or left in order to
select“ “ option and pressthebutton.
” menu appears.
Warning: When the product is not used for a long period (more than 15
days), remove the batteries. Otherwise, malfunctions that may occur
would beoutof warranty.
Your devicewillbe turned off and resetto factory settings.
Pleasethrowyour dead batteries into thewastebin forbatteries.
- If the Cooling Indicator is blinking, the cooling unit is
4
working.
- If the Cooling Indicator is steady, the cooling unit is not
working.
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is
working.
5
6
- If the Heating Indicator is steady, the heating unit is not
working.
ON/OFF and Temperature Setting Button
generallife.com.tr
2
1
3
| General | Details |
|---|---|
| Name | GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.04 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE MITRA 250S Wired Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with air circulation or close to heating/cooling units should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. MITRA 250S is a wired room thermostat that allows users to adjust room temperature for comfortable and economic heating/cooling. Operations within the heating/cooling unit or electrical installation must be carried out by professionally qualified persons. Temperature sensors in room thermostats are highly sensitive and may require calibration for accurate readings. Your room thermostat has heating and cooling modes that can be switched easily. You can reset your room thermostat to its default factory settings, which will reset calibration and heating/cooling modes. When the low battery icon appears, it is recommended to replace the batteries. If the cooling or heating indicator is blinking, it means the respective unit is working.
- Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. If the placement of the TPI Room Thermostats is changed or if they are de-energized, the learning process will restart and should be considered as taking 7 days. The TPI algorithm predicts temperature changes and controls the heating/cooling unit to maintain the set temperature with minimal deviations. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs covered by the warranty are conducted at the company factory, with transportation costs borne by the customer for on-site services. Malfunctions caused by customer misuse are not covered by the warranty, and damages from other brands without manufacturer approval are also excluded. The warranty document must be retained by the customer, and a replacement will not be issued if lost. The product is compatible with heating/cooling units that have on-off connections. The warranty period can be extended by the time spent on repairs if they occur within the warranty period. The manufacturer reserves the right to change product specifications and user manuals.