INSTALLATION INSTRUCTIONS  
91  
Installer setting – Air conditioner Fan operation interlocked with ventilation  
It is a function that sets the availability of air conditioner FAN movement when only the ventila-  
tion is running while air conditioner is off, in case of interlock of the air conditioner operation with  
the ventilation operation.  
If pressing  
button long for 3  
1
seconds, it enters into Air conditioner  
Fan operation interlocked with  
ventilation installer setup mode.  
- If pressing once shortly, it enters into  
user setup mode. Please press more  
than 3 seconds for sure.  
If moving to room temperature perception  
sensor selection menu by pressing  
button, it indicates as picture below.  
2
Set Thermistor value by pressing  
button. (00: air-conditioner fan operate very  
low, 01: air-conditioner fan off )  
3
Function Code  
Setting value  
Press  
button to save.  
4
5
Pressing  
button will exit settings mode.  
After setup, it automatically gets out of  
setup mode if there is no button input for  
25 seconds.  
When exiting without pressing set button,  
the manipulated value is not reflected.  