Home > LG > LG PREMTB10U Programmable Thermostat Instruction Manual

LG PREMTB10U Programmable Thermostat Instruction Manual

OPERATION INSTRUCTION  
33  
Function Setting - Minimum Difference Between Heating and  
Cooling Set Points  
This function sets the difference between Heating and Cooling set points.  
Press  
the  
button until  
icon flashes.  
1
2
Press  
buttons to change.  
minimum difference values  
: 0~10°F(0~5°C)  
Press  
the setting process.  
button to complete  
3
4
Press  
button to exit.  
After setup, it automatically exits  
after 60 seconds if there is no  
input. If the Setting/Cancel  
button is not pressed, the mode  
will not change.  
• When adjusting the minimum setting, both the heating and cooling set points will be ad-  
justed to maintain the value as a minimum between heating and cooling set points.  
* If power is lost for more than 50 hours, check displayed time and correct if needed.  