INSTALLATION INSTRUCTIONS  
92  
Installer setting – Indoor unit Auto-Start setting  
It is a function that sets whether to restore the indoor unit operation by resuming the previous  
power-on state or as power-off state in the power failure compensation.  
If pressing  
button long for 3  
1
seconds, it enters into Indoor unit  
Auto-Start setting installer setup mode.  
- If pressing once shortly, it enters into  
user setup mode. Please press more  
than 3 seconds for sure.  
If moving to room temperature perception  
sensor selection menu by pressing  
button, it indicates as picture below.  
2
Set Thermistor value by pressing  
button. (00: Use indoor unit auto restart,  
01: not use indoor unit auto restart)  
3
Function Code  
Setting value  
Press  
button to save.  
4
5
Pressing  
button will exit settings mode.  
After setup, it automatically gets out of  
setup mode if there is no button input for  
25 seconds.  
When exiting without pressing set button,  
the manipulated value is not reflected.  