INSTALLATION INSTRUCTIONS  
77  
Installer Setting - Emergency Heater Setting  
This function is only available on some products.  
This function will set the Emergency Heater Setting.  
Emergency Heater is used to heat the space in emergency cases such as heat pump error.  
Emergency heat is in place of and does not supplement heat pump.  
h Emergency Heater setting Function sets following conditions:  
1) Emergency Heater operation while in error or outdoor unit operating in the cooling cycle.  
2) Emergency Heater operation in Low Outdoor Ambient temperature  
3) Fan speed setting during Emergency Heater operation  
Press the  
button for 3  
1
seconds to enter the Thermostat  
installer setting.  
- If pressed for a shorter time,  
it enters into user setup mode.  
Repeat pressing  
Function code 18.  
button to select  
2
Function Code  
Setting1: Heater Operation while in error or  
outdoor unit operating in the  
cooling cycle.  
Select mode of Heater Operation while  
in error by pressing  
3
button  
00: not use  
01: use  
Setting2 : Low  
Outdoor Ambient  
Heating Operation  
Setting1 : Heater  
Operation while in  
error or outdoor  
unit operating in  
the cooling cycle.  
If 00 is set at this stage, setting 2 &  
setting 3 will not be available  
Setting3 : FAN  
Speed Setting  
during Emergency  
Heater Operation  
CAUTION  
!
This function setting must be carried out by a certified-technician.  
GeneralDetails
NameLG PREMTB10U Programmable Thermostat Instruction Manual
MakeLG
LanguageEnglish
FiletypePDF (Download)
File size4.55 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LG PREMTA200 Deluxe Thermostat User Guide
LG PREMTA200 Deluxe Thermostat User Guide

LG PREMTB10U Programmable Thermostat Instruction Manual