Home > WHITE RODGERS > WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

JUMPER  
WIRE  
THERMOSTAT  
SYSTEM  
Y
B
O
G
W
RC RH  
THERMOSTAT  
SYSTEM  
Y
B
O
G
W
RC  
RH  
Cooling  
System  
Fan  
Heating  
System  
NOTE  
Heating  
System  
Relay  
Hot  
RED jumper wire (provided  
with thermostat) must be  
connected between thermo-  
stat's RH and RC terminals  
for proper thermostat oper-  
ation with this system.  
24 VAC Transformer  
24 VAC  
120 VAC  
Neutral  
or  
Thermopile  
TRANSFORMER  
Figure 3. Typical wiring diagram for heating only,  
2-wire, single transformer systems or millivolt systems  
Figure 7. Typical wiring diagram for  
heat/cool, 4-wire, single transformer systems  
THERMOSTAT  
Thermostat  
NOTE  
Y
B
O
G
W
RC  
RH  
3-wire Series 10  
Primary Control  
(located at furnace)  
Jumper wire must be  
added between R and B  
terminals on the primary  
control (jumper wire not  
provided with thermostat).  
SYSTEM  
Hot  
Cooling  
Fan  
Heating  
R
W
24 VAC  
120 VAC  
Neutral  
System Relay System  
B
HEATING TRANSFORMER  
W
Hot  
R
24 VAC  
120 VAC  
Neutral  
Furnace  
Add jumper wire  
(not provided with thermostat)  
COOLING TRANSFORMER  
Figure 4. Typical wiring diagram for  
3-wire SERIES 10 heating systems  
Figure 8. Typical wiring diagram for  
heat/cool, 5-wire, two-transformer systems  
JUMPER  
WIRE  
JUMPER  
WIRE  
JUMPER  
WIRE  
THERMOSTAT  
SYSTEM  
THERMOSTAT  
SYSTEM  
Y
B
O
G
W
RC  
RH  
Y
B
O
G
W
RC RH  
NOTE  
Fan  
Heating  
System  
Reversing Compressor Fan  
Valve*  
Contactor Relay  
RED jumper wire (provided  
with thermostat) must be  
connected between thermo-  
stat's RH and RC terminals  
for proper thermostat oper-  
ation with this system.  
Relay  
Hot  
Hot  
24 VAC  
120 VAC  
Neutral  
24 VAC  
120 VAC  
Neutral  
* Reversing valve is energized when the  
system switch is in the COOL position  
TRANSFORMER  
TRANSFORMER  
Figure 9. Typical wiring diagram for  
heat pump with cool active reversing valve  
Figure 5. Typical wiring diagram for  
heat only, 3-wire, single transformer systems  
JUMPER  
WIRE  
JUMPER  
WIRE  
THERMOSTAT  
THERMOSTAT  
SYSTEM  
Y
B
O
G
W
RC  
RH  
Y
B
O
G
W
RC RH  
SYSTEM  
Cooling  
System  
Fan  
Reversing Compressor Fan  
Valve*  
Contactor Relay  
Hot  
Hot  
Relay  
24 VAC  
24 VAC  
120 VAC  
120 VAC  
Neutral  
* Reversing valve is energized when the  
system switch is in the HEAT position  
Neutral  
TRANSFORMER  
TRANSFORMER  
Figure 6. Typical wiring diagram for  
cool only, 3-wire, single transformer systems  
Figure 10. Typical wiring diagram for  
heat pump with heat active reversing valve  
3. Move fan switch to AUTO position. The blower should stop  
immediately.  
CHECK THERMOSTAT OPERATION  
If at any time during testing your system does not operate  
properly, contact a qualified serviceperson.  
Heating System  
1. Move SYSTEM switch to HEAT position. If the heating  
system has a standing pilot, be sure to light it.  
Fan Operation  
If your system does not have a G terminal connection, skip to  
Heating System.  
2. Press  
to adjust thermostat setting above room tempera-  
ture. The heating system should begin to operate.  
1. Turn on power to the system.  
2. Move fan switch to ON position. The blower should begin to  
operate.  
3. Press  
toadjusttemperaturesettingbelowroomtempera-  
ture. The heating system should stop operating.  
3
GeneralDetails
NameWHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.12 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual