SPECIFICATIONS
6
ELECTRICAL DATA
THERMAL DATA
Setpoint Temperature Range: 45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range: 32°F to 105°F
Operating Humidity Range: 0 to 90% RH (non-condensing)
Shipping Temperature Range: -40°F to 150°F
Electrical Rating:
0 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
TROUBLESHOOTING
7
Reset Operation
and still does not function correctly contact your heating/cooling
service person or place of purchase.
If a voltage spike or static discharge blanks out the display or
causeserraticthermostatoperationyoucanresetthethermostat
Batteries
by pressing
SYSTEM switch from OFF to HEAT.This also resets the factory
and
at the same time while moving the
For optimum performance, we recommend replacing batteries
once a year with fresh “AAA” Energizer® alkaline batteries.
defaults. If the thermostat has power, has been reset
Symptom
Possible Cause
Corrective Action
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
Replace fuse or reset breaker.
No Heat
(common problems)
Turn switch to ON.
3. Furnace blower compartment door or panel
loose or not properly installed.
Replace door panel in proper position to engage safety interlock or door switch.
1. Pilot light not lit.
Re-light pilot.
No Heat
2. SYSTEM Switch not set to HEAT.
3. Loose connection to thermostat or system.
Set SYSTEM Switch to HEAT and raise temperature above room temperature.
Verify thermostat and system wires are securely attached.
4. Furnace Lock-Out Condition. Heat may also be
intermittent.
Many furnaces have safety devices that shutdown when a lock-out condition
occurs. If the heat works intermittently contact the furnace manufacturer or local
service person for assistance.
5. Heating system requires service or thermostat
requires replacement.
Diagnostic: Set SYSTEM Switch to HEAT and raise the setpoint above room
temperature. Within a few seconds the thermostat should make a soft click sound.
This sound usually indicates the thermostat is operating properly. If the thermo-
stat does not click, try the reset operation listed above. If the thermostat does not
click after being reset contact your heating and cooling service person or place of
purchase for a replacement. If the thermostat clicks, contact the furnace manufac-
turer or a service person to verify the heating is operating correctly.
1. Possible short in wiring.
Check each wire connection to verify they are not shorted or touching together.
No bare wire should stick out from under terminal screws.Try resetting the
thermostat as described above. If the condition persists the manufacturer of your
system or service person can instruct you on how to test the Heat system for
correct operation. If the system operates correctly, replace the thermostat.
Heat, Runs
Constantly
2. Possible short in thermostat.
3. Possible short in heat system.
1. The location of the thermostat and/or the
size of the Heating System may be
influencing the cycle rate.
Digital thermostats normally provide precise temperature control and may
cycle faster than some older mechanical models. A faster cycle rate means the
unit turns on and off more frequently but runs for a shorter time so there is no
increase in energy use. If you would like to increase the cycle time, clip Jumper
W-905 as mentioned in the instructions for Hydronic Heating Systems. It is not
possible to shorten the cycle time. If an acceptable cycle rate is not achieved
as received or by clipping W-905 contact a local service person for additional
suggestions.
Furnace Cycles Too
Fast or Too Slow
(narrow or wide
temperature swing)
1. Thermostat thermometer setting requires
adjustment.
The thermometer can be adjusted +/- 3 degrees. See Temperature Display
Adjustment in the Operation section.
Thermostat Setting and
Thermostat Thermometer
Disagree
1. Voltage spike or static discharge.
2. Battery change required.
Replace batteries and check heat/cool system for proper operation. If a voltage
spike occurs use the Reset Operation listed above.
Blank Display and/or
Keypad Not Responding
Homeowner Help Line: 1-800-284-2925
White-Rodgers is a division
of Emerson Electric Co.
The Emerson logo is a
trademark and service mark
of Emerson Electric Co.
| General | Details |
|---|---|
| Name | White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.27 MB |

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual