10 - CONFIGURATION MENU (Installer)  
10.6.2 - RESETTABLE COMMAND on N.C. external contact “Normally Closed”  
Confirmed screen for the management of the resettableN.C. external contact with a command on the thermostat  
aspertheprocedureinparagraph10.6, thefollowingoperationisobtained:  
Do not enable the item prior to connecting a switch or other device that allows change of state  
from OFF mode to current operating mode and vice versa to terminals 1 and 2 (AUX)..  
Thermostat operation  
e.g. external contact N.C.  
Contact opening  
activates level and Tset OFF ANTI-FREEZE if in WINTER ( ) or THERMAL PROTECTION in SUMMER (  
)
return to the level and Tset active before closing the contact  
Contact closure  
For the operating principle procedure and the displays on the display when the state of the external contact changes and/or reset with control directly on the  
thermostat, see images shown in the previous paragraph 10.6.1. taking into account that the contact is normally closed N.C. and not N.A.  
10.6.3 - NON-RESETCABLE COMMAND on external N.O. contact. «Normally Open»  
Confirmedscreen  
ofexternalcontactmanagementN.A. aspertheprocedureinparagraph10.6thefollowingoperationisobtained:  
Thermostat operation  
e.g. external contact N.A.  
Contact closure  
Contact opening  
activates level and Tset OFF ANTI-FREEZE if in WINTER ( ) or THERMAL PROTECTION in SUMMER (  
)
return to the level and Tset active before closing the contact  
Livello OFF  
Return to the level  
before contact closure  
example from mode: WINTER  
flashes  
example with open window  
which closes the N.O. contact.  
Closing the window  
opens the N.A. contact.  
Note:  
a
flashing “bLOC” will  
appear when any button is  
pressed.  
contact opening and closure controls are operative within max 60 sec.  
The change of state from open remote contact to closed contact causes forcing into the permanent manual OFF state (antifreeze or thermal  
protection) with the display of the flashing “ “ icon (to indicate an active forcing situation). The OFF level can result in actual temperature control  
atacertainTsetvalue(e.g. 5°C)ortemperaturecontrolswitchedoff, seepar. 10.5.  
The subsequent change of state from closed contact to open contact causes the end of the manual forcing OFF and the automatic loading of the  
levelthatwasactivebeforetheforcing;theicon  
22  
willbeswitchedoff.  