PERRY TE541 Digital Thermostat User Manual
10 - CONFIGURATION MENU (Installer)
10.4.2 - SETTING PERIOD DURATION FOR
MODULATING PROPORTIONAL IN TIME
•Select the SEt rEG PrOP, menu screen, as described in paragraph
10.4.1.
•Press the
button to display the next menu SEt Per (period
duration).
•Confirm with OK if you want to change the period duration, the current
value flashes.
•With the
buttons, enter the duration of the desired period
(settable from 7 to 20 minutes, default 7 minutes).
•Press OK to confirm.
•Press
to select another menu item or press the Mode button to exit
the menus and return to normal operation.
10.4.3 - SETTING HYSTERESIS FOR
THERMAL DIFFERENTIAL ON-OFF
•Select the SEt rEG On:OF menu screen, as described in paragraph
10.4.1.
•Press the button to display the next menu SEt Ist (Hysteresis).
•Confirm with OK if you want to change the hysteresis, the current
value flashes.
•Use the buttons
to enter the desired hysteresis value, which
can be set from 0.2 °C to 1.2 °C (default 0.3 °C).
•Press OK to confirm.
•Press
to select another menu item or press the Mode button to exit
the menus and return to normal operation..
18
| General | Details |
|---|---|
| Name | PERRY TE541 Digital Thermostat User Manual |
| Make | PERRY |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.4 MB |