Installation Manual - 7602-457 Communicating, Programmable Thermostat  
The Auto Changeover Time is the amount of time that  
elapses before operation switches from heating to  
cooling mode or from cooling to heating mode.  
1.0 User Menu Settings  
1.1 OFFSETS  
If you nd that the temperature displayed on the  
thermostat does not accurately represent the room  
temperature where the thermostat is located, this  
offset function compensates for the difference.  
The thermostat will apply an offset between what  
temperature the thermostat is measuring versus the  
temperature that is displayed.  
Adjust the Auto Changeover Time using the up/  
down arrow buttons. Press the center button to save  
changes.  
Auto Change Over Time (default 15 minutes):  
options: 0 to 120 minutes (in 15 minute  
increments)  
1.3 DEMO MODE  
1.1.1 TEMPERATURE OFFSET  
Demo mode is designed to showcase heat pump  
operation when the unit is connected to an above  
ground water loop with the supply air being blown  
directly over the water loop.  
The Temperature Offset function allows for  
calibration of the temperature sensor.  
Adjust the Temperature Offset settings using the  
up/down arrow buttons. Press the center button to  
save changes.  
1.3.1 ENTER DEMO MODE  
To enter Demo Mode, navigate to the Service  
Information screen (Menu>Settings>Service  
Information) then press and hold the right arrow for  
5 seconds  
Indoor Temperature (default 0°F): options:  
-5°F to +5°F (in 1°F increments)  
Remote Temperature (default 0°F): options:  
-5°F to +5°F (in 1°F increments)  
Outdoor Temperature (default 0°F): options:  
-5°F to +5°F (in 1°F increments)  
SERVICE INFORMATION  
FAULT STATUS  
1st Stage (default 1°F): options: 1°F to 4°F  
(in 1°F increments)  
2nd Stage (default 1°F): options: 1°F to 4°F  
(in 1°F increments)  
Aux Heat (default 1°F): options: 1°F to 4°F  
(in 1°F increments)  
CLEAR FAULT HISTORY  
SYSTEM STATUS  
NOTE 1: The thermostat must be congured for  
Multistage by installer to access the 2nd Stage  
Differential setting. The thermostat must be  
congured for Auxiliary Heat by installer to access  
the Auxiliary Heat Differential setting.  
SELECT OPTION  
PREVIOUS  
1.3.2 DEMO MODE OPERATION  
Control Demo Mode operation parameters from the  
Demo Operation screen shown below.  
NOTE 2: The temperature control algorithm must  
be congured for Differential control to access the  
Differential settings by installer.  
DEMO OPERATION  
OUTDOOR  
78%  
RH 36%  
FAN AUTO  
HEATING  
1.1.2 HUMIDITY OFFSET  
HUMID ON  
If you nd that the Humidity level displayed on  
the thermostat does not accurately represent the  
Humidity level of the room in which the thermostat  
is located, use the Humidity Offset function to  
calibrate the humidity sensor.  
AUTO  
SETPOINT  
HEAT 70  
COOL 74  
72%  
Adjust the Humidity Offset setting using the up/  
down arrow buttons. Press the center button to  
save changes.  
RH  
TEMP  
MODE  
FAN  
MENU  
Indoor Humidity (default 0%): options:  
-10% to +10% (in 1% increments)  
1.2 AUTO CHANGEOVER TIME  
When the thermostat is congured for AUTO mode,  
the thermostat automatically selects heating or  
cooling mode depending on the indoor temperature.  
4
GeneralDetails
Namemars 7602-457 Communicating Programmable Thermostat Instruction Manual
MakeMARS
LanguageEnglish
FiletypePDF (Download)
File size0.49 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

mars 7602-457 Communicating Programmable Thermostat Instruction Manual