mars 7602-457 Communicating Programmable Thermostat Instruction Manual
Installation Manual - 7602-457 Communicating, Programmable Thermostat
3.1
AIRFLOW SELECTION
3.0 System Configuration
Adjust the airflow settings for each system operating mode
using the up/down arrow buttons. Press the center button to
select each item.
Use the System Configuration option on the start-up screen
to adjust critical equipment settings.
•
Airflow Settings (defaults stored in control)
- valid range: obtained from control (in 25 CFM
increments)
The System Configuration information will be automatically
obtained from each communicating control in the system.
•
Blower Off Delay (default 60 seconds) – valid
range: 0 to 255 seconds (in 5 second increments)
Note 1: The Airflow Selection menu (section 3.1) will not be
present if the connected communicating control system has
no blower.
NOTE 1: The Airflow Settings will only be present if the
connected communicating control is configured for ECM
blower.
Note 2: The Pump Configuration menu (section 3.4) will
not be present if the connected communicating control is
configured for No Loop Configuration (OTHER).
NOTE 2: If multiple units are connected to one thermostat,
refer to section 3.6 for unit selection.
Note 3: The Valve Configuration menu (section 3.5) will
not be present if the connected communicating control is
configured for No Loop Configuration (OTHER).
AIRFLOW SELECTION
CFM
HEAT STAGE 1
600
750
850
850
525
700
425
550
350
60
HEAT STAGE 2
AUXILIARY HEAT
EMERGENCY HEAT
COOL STAGE 1
INSTALLER SETTINGS
THERMOSTAT CONFIG
SYSTEM CONFIG
COOL STAGE 2
ACCESSORY CONFIG
INPUT DEALER INFO
HUMIDITY CONFIG
COOL DEHUMID 1
COOL DEHUMID 2
CONTINUOUS FAN
HEAT OFF DELAY
COOL OFF DELAY
TEMPERATURE CONTROL
DEMAND REDUCTION CNFG
SERVICE MODE
30
SETPOINT LIMITS
PREVIOUS
NEXT
RESTORE DEFAULTS
DXM2
3.3
3.2
OPTION SELECTION
C 1.0
7602-457
This option allows the configuration of heat pump options to
be modified.
SELECT OPTION
PREVIOUS
Adjust the Option settings using the up/down arrow buttons.
Press the center button to select each item.
SYSTEM CONFIGURATION
AIRFLOW SELECTION
OPTION SELECTION
UNIT CONFIG
•
Motorized Valve (defaults stored in control) –
valid range: Off, On “On” delays compressor start
until the valve is fully open.
TE026
NOTE: “Motorized Valve” used here refers to a two-position
motorized water valve, not to be confused with the modulating
motorized water valve found in the LOOP CONFIG.
PUMP CONFIGURATION
•
Compressor ASCD (Anti-Short Cycle Delay
(default stored in control) – valid range: 5 to 8
(in 1 minute increments)
SELECT OPTION
PREVIOUS
SAVE
NOTE 1: The Compressor Anti-Short Cycle Delay setting
provides equipment protection by forcing the compressor to
wait a few minutes before restarting.
NOTE 2: If multiple units are connected to one thermostat,
refer to section 3.6 for unit selection.