Home > MARS > mars 7602-457 Communicating Programmable Thermostat Instruction Manual

mars 7602-457 Communicating Programmable Thermostat Instruction Manual

Installation Manual - 7602-457 Communicating, Programmable Thermostat  
F
A
U
L
T
C
O
N
D
I
T
I
O
N
M
E
N
U
FAULT I / O CONDITIONS  
LT1 LOW WATER TEMP  
HEAT 1 11:11 AM 11/14  
LT1 LOW WATER TEMP  
HEAT 1 11:11 AM 11/14  
TSTAT  
SAFETY  
HPS  
O
U
T
P
T
FAULT TEMP CONDITIONS  
FAULT FLOW CONDITIONS  
FAULT I/O CONDITIONS  
FAULT CONFIG COND  
CONV COMM  
Y1  
Y2  
W
Y1  
Y2  
W
O
LOC  
CC  
CO  
RV  
ACC1  
ACC2  
AL1  
O
OUTPT  
FAN  
G
G
H
H
HWG  
PUMP  
EH1  
EH2  
OVR  
DH  
FAULT POSSIBLE CAUSES  
PREVIOUS  
SELECT  
PREVIOUS  
9.4.1 Temperature Conditions  
9.4.4 Conguration Conditions  
Displays detailed temperature readings that were  
recorded at the time the fault occurred.  
Displays the status of all dipswitch settings that were  
recorded at the time the fault occurred.  
NOTE: If multiple units are connected to one thermostat, refer  
NOTE: If multiple units are connected to one thermostat, refer  
to section 9.6.  
to section 9.7.  
FAULT TEMPERATURE CONDITIONS  
LT1 LOW WATER TEMP  
HEAT 1 11:11 AM 11/14  
FAULT CONFG CONDITIONS  
LT1 LOW WATER TEMP  
HEAT 1 11:11 AM 11/14  
LT1 TEMP  
28.1  
97.3  
S1  
S2  
ON  
S3  
LT2 TEMP  
1
2
3
4
5
6
7
8
ON  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
1
2
3
4
5
6
7
8
1
2
3
4
ON  
HOT WATER EWT  
COMP DISCHARGE  
LEAVING AIR  
121.5  
157.7  
92.7  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
OFF  
LEAVING WATER  
ENTERING WATER  
CONTROL VOLTAGE  
34.9  
42.1  
LT1 WELL  
LT2 WELL  
26.4  
PREVIOUS  
PREVIOUS  
9.4.2 Flow Conditions  
Displays detailed blower and pump speed / valve  
position readings that were recorded at the time the  
fault occurred.  
9.4.5 Possible Causes  
Possible causes as to why the fault occurred  
NOTE: If multiple units are connected to one thermostat, refer  
to section 9.7.  
NOTE: If multiple units are connected to one thermostat, refer  
to section 9.7.  
POSSIBLE FAULT CAUSES  
LOW WATER COIL TEMP  
FAULT FLOW CONDITIONS  
LT1 LOW WATER TEMP  
HEAT 1 11:11 AM 11/14  
LOW WATER TEMP - HTG  
LOW WATER FLOW - HTG  
LOW REFRIG CHARGE - HTG  
INCORRECT LT1 SETTING  
BAD LT1 THERMISTOR  
PREVIOUS  
ECM TARGET CFM  
ECM BLOWER RPM  
FLOW RATE GPM  
PUMP SPEED  
800  
550  
6.5  
60%  
140  
PUMP WATTS  
LOOP CONFIG  
PREVIOUS  
VS PUMP  
SINGLE  
9.4.3 Input/Output Conditions  
9.5  
CLEAR FAULT HISTORY  
Displays the status of all physical and communicated  
inputs, switches, and control outputs that were  
recorded at the time the fault occurred.  
Clear Fault History will clear all fault codes stored in the  
thermostat as well as the fault history in any connected  
communicating controls (DXM2/AXM).  
NOTE: If multiple units are connected to one thermostat, refer  
to section 9.7.  
14  
GeneralDetails
Namemars 7602-457 Communicating Programmable Thermostat Instruction Manual
MakeMARS
LanguageEnglish
FiletypePDF (Download)
File size0.49 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

mars 7602-457 Communicating Programmable Thermostat Instruction Manual