mars 7602-457 Communicating Programmable Thermostat Instruction Manual
Installation Manual - 7602-457 Communicating, Programmable Thermostat
2.2.1
STAGING
2.0 Installer Menu Settings
Adjust the staging option using the up/down arrow buttons.
Press the center button to save changes.
2.1
INSTALLER MENU SETTINGS ACCESS
•
Single Stage – for control of a single stage
compressor applications
Multi-Stage (default) – for control of multi-
stage compressor applications
The Installer Settings can be accessed at any time from the
Main Operating screen by holding the up/down arrows simul-
taneously for 5 seconds while the thermostat is in OFF Mode.
•
THERMOSTAT
CONFIGURATION
SINGLE STAGE
MULTI STAGE
Installer Menu Settings Overview
Thermostat Configuration
System Configuration
Airflow Selection
SELECT OPTION
PREVIOUS
SAVE
Option Selection
2.2.2
AUXILIARY HEAT
Unit Configuration
Pump Configuration
Valve Configuration
Accessory Configuration
Air Filter
Adjust the Auxiliary Heat options using the up/down arrow
buttons. Press the center button to save changes.
•
•
•
Electric (default) – for control of a system with
electric auxiliary heat
Multi-Fuel – for control of a system with furnace
for auxiliary heat
No Auxiliary Heat – for control of a system with no
auxiliary heat
Humidifier
UV Lamp
Air Cleaner
Input Dealer Information
Humidity Configuration
Temperature Algorithm
Demand Reduction Configuration
Service Mode
THERMOSTAT
CONFIGURATION
ELECTRIC
Manual Operation
Control Diagnostics
Dipswitch Configuration
Fault History
MULTI FUEL
Clear Fault History
Restore Defaults
NO AUXILIARY HEAT
2.2
THERMOSTAT CONFIGURATION
SELECT OPTION
PREVIOUS
SAVE
Upon initial power up, the communicating thermostat will
prompt the installer for the thermostat configuration settings.
2.2.2.1 AUXILIARY HEAT CONFIGURATION
Select Electric Auxiliary Heat mode
Model number and software version of thermostat and
software version of connected DXM2 are also displayed on
this screen.
•
•
Auxiliary Heat to Supplement Pump
Auxiliary Heat for Emergency Heat Only
THERMOSTAT
INSTALLER SETTINGS
THERMOSTAT CONFIG
SYSTEM CONFIG
CONFIGURATION
ACCESSORY CONFIG
INPUT DEALER INFO
HUMIDITY CONFIG
AUXILIARY HEAT TO
SUPPLEMENT HEAT PUMP
TEMPERATURE CONTROL
DEMAND REDUCTION CNFG
SERVICE MODE
AUXILIARY HEAT FOR
EMERGENCY HEAT ONLY
SETPOINT LIMITS
RESTORE DEFAULTS
DXM2
3.3
C 1.0
SELECT OPTION
PREVIOUS
7602-457
SELECT OPTION
PREVIOUS
SAVE
6