Home > WHITE RODGERS > White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

WIRING CONNECTIONS  
Single Stage Connections  
Refer to equipment manufacturers' instructions for specific system  
wiring information.  
This thermostat is designed to operate a single-transformer or two-  
transformer system.  
SINGLE STAGE gas, oil or electric.  
After wiring, see INSTALLER CONFIGURATION section for proper  
thermostat configuration.  
You can configure the thermostat for use with the following systems:  
Single Stage System with Single Transformer  
To Remote Temperature Sensor  
Jumper  
B
O
RC  
+
Y
G
RH  
C*  
S
-
W
6
L
System  
Blower/  
Circula-  
tor Fan  
Energiz-  
ed on  
DC  
DC  
Return  
to  
Energized  
on call  
Single  
Stage  
(SS)  
supply  
voltage  
to re-  
24 Volt  
Com-  
mon  
Remote  
Temp-  
erature  
Sensor  
signal  
Third  
Diagnostic  
Indicator  
(See  
Energized Energiz-  
24 Volt  
(Hot)  
Heat  
Energized  
on call for  
Heat  
24 Volt  
(Hot)  
Cool  
wire for  
3-wire  
zone  
for Cool  
(Com-  
pressor)  
in Heat  
or Off  
Mode  
ed in  
Cool  
Mode  
Remote  
Temp-  
erature  
Sensor  
call for  
Cool &  
for Heat  
(if ELE  
is sel-  
mote  
(option-  
al)  
1
Note  
)
Temp-  
erature  
Sensor  
valve  
ected)  
NEUTRAL  
24VAC  
HOT  
120VAC  
CLASS II  
TRANSFORMER  
* Common connection  
required for fault or  
malfunction indication  
and remote sensor.  
Single Stage with Two Transformers  
To Remote Temperature Sensor  
Remove Jumper Wire  
between RH & RC  
NOTE: If continuous backlight or hardwired  
power input are desired but do not function  
in both HEAT and COOL modes, cut the  
heating transformer 24V wires and tape off.  
Connect the neutral circuit disconnected  
from the heating transformer to the neutral  
circuit of the cooling transformer. Discon-  
nect the wire to the RH terminal and install  
a jumper between RH and RC. Depending  
on the system requirements, replace the  
cooling transformer with a 75VA class II  
transformer if needed.  
Jumper  
B
O
RC  
+
Y
G
RH  
C*  
S
-
W
6
L
System  
Blower/  
Circula-  
tor Fan  
Energiz-  
ed on  
DC  
DC  
Return  
to  
Energized  
on call  
supply  
voltage  
to re-  
24 Volt  
Com-  
mon  
Remote  
Temp-  
erature  
Sensor  
signal  
Single  
Stage  
(SS)  
Energized Energized  
in Cool  
Mode  
Diagnostic  
Indicator  
(See  
24 Volt  
(Hot)  
Heat  
Energized  
on call for  
Heat  
Third wire  
for 3-wire  
zone valve  
24 Volt  
(Hot)  
Cool  
for Cool  
(Com-  
pressor)  
in Heat,  
Off Mode  
Remote  
Temp-  
erature  
Sensor  
call for  
Heat or  
Cool  
mote  
(option-  
al)  
Temp-  
erature  
Sensor  
1
Note  
)
(if ELE  
is sel-  
ected)  
NEUTRAL  
120VAC  
24VAC  
HOT  
NEUTRAL  
24VAC  
HOT  
120VAC  
COOLING  
CLASS II  
TRANSFORMER  
* Common connection  
required for fault or  
malfunction indication  
and remote sensor.  
HEATING  
CLASS II  
TRANSFORMER  
NOTE : Connection for Call for Service diagnostic indicator compatible with mechanical or electronic condenser control with Comfort AlertTM.  
3
GeneralDetails
NameWhite-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.49 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual