INSTALLER/CONFIGURATION MENU  
20) Comfort Alert with Active Protection Turn this  
feature ON to enable active protection. This allows the  
thermostat to identify fault codes sent by the Comfort  
Alert module when compressor damage is possible and  
react to those codes by turning the compressor off. Fault  
codes from the Comfort Alert module will flash on the  
thermostat. (Refer to Comfort Alert Yellow Alert Codes  
in Troubleshooting section.) If a Comfort Alert module is  
not connected, or to disable active protection, turn this  
feature OFF. If a Comfort Alert module is connected and  
this feature is turned OFF, the thermostat will still receive  
and flash the fault codes from the Comfort Alert module,  
but the active protection will not be enabled to protect the  
compressor.  
22) Select Filter Replacement Reminder and Set Run  
Time – Select the “Change Filter” reminder On or  
OFF. If selected On, press MENU to select the time  
period from 25 to 1975 hours in 25 hours increments.  
In a typical system, 200 hours (default) of run time is  
approximately 30 days. After the selected time of blower  
operation, the thermostat will display “Change Filter”  
as a reminder to change or clean your air filter. When  
“Change Filter” is displayed, press MENU or RUN  
SCHED button to clear the display and restart the time to  
the next filter change.  
23) Select Reversing Valve Output – The O/B option is  
factory set at “O” position. This will accommodate the  
majority of heat pump applications, which require the  
changeover relay to be energized in COOL. If the  
thermostat you are replacing or the heat pump being  
installed with this thermostat requires a “B” terminal, to  
energize the changeover relay in HEAT, the O/B option  
should be set at “B” position.  
21) Select Daylight Saving Time Calculation – Not  
available on 1F83, this feature will allow the thermostat to  
calculate the DST automatically and apply it to the Real  
Time Clock display. Default On. Use  
to select the feature OFF.  
or  
buttons  
OPERATINGYOUR THERMOSTAT  
IMPORTANT!  
Choose the Fan Setting (Auto or On)  
Press the FAN button to Auto or On.  
Manual Operation for Non-Programmable  
Mode  
Press the SYSTEM button to select Heat or Cool and use  
Fan Auto is the most commonly selected setting and runs the  
fan only when the heating or cooling system is on.  
Fan On runs the fan continuously for increased air circulation  
or to allow additional air cleaning.  
the  
or  
buttons to adjust the temperature to your  
desired setting. After selecting your desired settings you can  
also press the SYSTEM button to select AUTO to allow the  
thermostat to automatically change between Heat and Cool.  
Choose the System Setting  
(Heat, Off, Cool, Auto, Emer)  
Press the SYSTEM button to select:  
Manual Operation (Bypassing the Program)  
Programmable Thermostats  
Press  
or  
and then the HOLD button and adjust the  
Heat: Thermostat controls only the heating system.  
Off: Heating and Cooling systems are off.  
temperature wherever you like. This will override the program.  
The HOLD feature bypasses the program and allows you  
to adjust the temperature manually, as needed. Whatever  
temperature you set in HOLD will be maintained 24 hours  
a day, until you manually change the temperature or press  
Run Sched to cancel HOLD and resume the programmed  
schedule.  
Cool: Thermostat controls only the cooling system.  
Auto: Auto Changeover is used in areas where both heating  
and cooling may be required on the same day. AUTO allows  
the thermostat to automatically select heating or cooling  
depending on the indoor temperature and the selected heat  
and cool temperatures. When using AUTO, be sure to set the  
Cooling temperatures more than 1° Fahrenheit higher than  
the heating temperature.  
Program Override (Temporary Override)  
Press  
or  
buttons to adjust the temperature. This  
Emer: (Heat Pump models) Thermostat controls only backup  
heating system.  
will override the temperature setting for four hours. To cancel  
the temporary setting at any time and return to the program,  
press Run Sched. If the SYSTEM button is pressed to select  
AUTO the thermostat will change to Heat or Cool, whichever  
ran last. If it switches to heat but you want cool, or it changes  
to cool but you want heat, press both  
simultaneously to change to the other mode.  
and  
buttons  
PROGRAMMING (For Programmable Model Only)  
Set Current Time and Date  
1) Press Menu and then Time button once. The display  
will show the hour only.  
5) Additional presses of Time will advance the display  
to show the year, month and date of month. Press the  
or button to change the display to the correct  
2) Press and hold either the  
or  
button until you  
setting for each.  
6) Press Run Sched to exit the Time mode.  
reach the correct hour and AM/PM designation (AM  
begins at midnight, PM begins at noon).  
3) Press Time once again. The display window will show  
the minutes only.  
4) Press and hold either the  
reach the correct minutes.  
or  
button until you  
7
GeneralDetails
NameWhite Rodgers 1F85CA-0471 Blue Universal Thermostat Instruction Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.37 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

White Rodgers 1F85CA-0471 Blue Universal Thermostat Instruction Manual