Home > GENERAL LIFE > GENERAL LIFE Senna 270S RF Wireless Room Thermostat User Manual

GENERAL LIFE Senna 270S RF Wireless Room Thermostat User Manual

ScreenIndicators  
RECEIVER WIRING DIAGRAM  
ENGLISH  
AC  
COM  
NO  
(230V)  
5
DIGITAL ROOM THERMOSTAT  
6
7
1
2
generallife.com.tr  
BATTERY PLACEMENT  
3
4
SENNA 270 RF USER MANUAL  
HEATING/COOLING UNIT  
GENERAL SPECIFICATIONS  
1
2
3
4
5
Room Temperature  
SENNA270RFis awirelessroom thermostat. The user can adjust the  
room temperaturewiththerequired temperatureand getmore  
comfortable and economic heating/cooling.  
Warning!  
Operations within the heating / cooling unit or the electrical installation  
must be carriedout byprofessionally qualified persons.  
Set Temperature  
Economy Mode  
Comfort Mode  
Battery Indicator  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Different Mode Options (Comfort Mode and Economy Mode)  
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER  
PreciseTemperatureMeasurement  
Heating Calibration  
ON/OFFControl  
WirelessConnection  
TPIAlgorithm  
6
7
Primarily press the sync button of receiver for 2 seconds and see blinking  
green light of receiver.  
Heating/Cooling Modes  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
As shown in the picture above, press the screwdriverforward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace  
both batteries at the same time. Then align the front part of your Room  
Thermostatto the backand squeezeittowards theback.  
SENNA 270 RF AND EQUIPMENTS  
Press thebutton until the “  
” menu appears.  
SENNA 270 RF Room Thermostat  
Holder  
Alkaline  
Battery  
Press the "+" or "-" button of your Room Thermostat while the LED is  
flashing green.  
RECEIVER  
1-Manual Operation Button:  
By disabling the Receiver, it enables you to  
use your boiler manually.  
If the pairing is successful, the green flashing LED on the receiver will be  
constant.  
1
2
3
Low Battery Warning: When the “  
” icon appears on the screen, it means  
“low battery warning”. It is recommended to replace the batteries when this  
warning appears.  
Receiverand Room Thermostathavebeen paired to each other.  
2-Pairing Button:  
Allows to pair the Receiver with the Room  
Thermostat.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Boiler Connection Cable Input  
Dowels and Screws  
Receiver  
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty.  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like  
to get the same temperature values with other thermometers in your living  
space.  
Please throwyour dead batteries into thewaste bin forbatteries.  
RECEIVER PLACEMENT  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
4 5  
RECEIVER LED DESCRIPTIONS  
The important things to note for the Receiver  
placement is avoiding physical contact between the  
Receiver and heating/cooling unit, and protecting it  
against materialssuch asliquid, dust etc.  
Press the "On/Off" button until the “  
” menu appers. In order to see the  
TECHNICAL DATA  
Room Thermostat  
desired temperature, set the temperature difference by press the  
“Temperature Adjustment Buttons”. This value can be arranged between  
“-8oC" and “+8oC".  
Dimensions  
Operating Current  
85mm / 125mm / 19mm  
3V DC (2 x AAA alkaline battery)  
Steady Red  
Receiver has power but Receiver and  
Room Thermostat are not paired.  
Waiting for pairing signal from Room Thermostat.  
Receiver and Room Thermostat are paired.  
Boiler is not operating.  
To save the settings and exit, press the "On/Off" button until the device  
turns off.  
Temperature Measurement Accuracy 0.1oC  
Blinking Green  
Steady Green  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
(5oC) – (30oC)  
1 Years (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
The devices should be placed in order to minimize the damage to the  
receivedand transmittedsignals bypayingattentiontothefollowingpoints;  
Note:Recommended tempreturecalibration is “0.0oC”.  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputers and televisionunits.  
The devices should not be installed near large metal structures or other  
building materials using fine metal meshes such as special glass or  
special concrete.  
3 Short Orange  
Blinking  
Operate the boiler signal has reached to the  
Receiver.  
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings. This  
operation resets the mode temperature values, calibration setting and  
heating/coling modes to factory setting. To reset your Room Thermostat to  
factory setting:  
Steady Orange  
3 Short Green  
Blinking  
Boiler is operating.  
Shut the boiler down signal has reached to the  
Receiver.  
Receiver  
Dimensions  
Operation Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
Blinking Orange  
Boiler is operating in manual mode.  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
Distance between the Room Thermostat and the Receiver should not  
exceed 20metersor 2 floors.  
Blinking Red  
Receiver did not get a signal from the  
Room Thermostat for 22 minutes or longer and  
boiler has shut down.  
Storage Temperature  
PresstheOn/Off” button until “  
” menu appears.  
Receiver must be installed at least 50 cm away from the heating/cooling  
unit.  
While in the “ ” menu, select the “ ” option by using “+” or “-” buttons  
ROOM THERMOSTAT  
Buttons Functions  
and press theOn/Off” button.  
ROOM THERMOSTAT PLACEMENT  
Your devicewill be turned off and resetto factory settings.  
RECEIVER SETUP  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room or side  
of window should be avoided. Also anywhere close to heating/cooling units  
such as radiator, stove and spots which get direct sun lights would not be  
suitable. Room Thermostat needs to be located above the floor 150 cm  
height. Fewtrialsmaybe made to find themost convenientspot.  
First, shut down your heating/cooling unit and your heating/cooling unit's  
power sourcewithall electricalcurrent(fuse, socketetc.)  
As shown in the connection diagram, connect one end of the  
heating/cooling unit connection cable to the COM and the other to the NO  
input of theReceiver.  
MODE SETTINGS  
There are 2 modes in the Room Thermostat. These are Comfort Mode “  
1
and Economy Mode “ ”. Modes work according to the pre-set temperature  
valuesadjusted byuser.  
2
3
In order to change the comfort mode temperaturevalue;  
Connect the other ends of the cable -which you connected to the Receiver  
to room thermostat connection terminal as shown in your  
heating/cooling unit's user manual.  
4
Press and hold thecomfort mode button for 3 seconds.  
Change the temperaturevaluebypressing “+” or “-“ buttons.  
Press the comfort mode button once to save the changes you have made  
or wait10seconds.  
You must first connect the Receiver power cable to the Receiver and then  
to thefuse to which theheating/cooling unit is connected.  
After completing the cable connection process, firstly turn on your fuse  
and then yourheating/cooling unit.  
5
6
In order to change theeconomy mode temperature value;  
1
2
3
4
5
6
ON/OFF and Setting Button  
Economy Mode  
Comfort Mode  
Heating/Cooling Modes  
Temperature Adjustment (Increasing)  
Temperature Adjustment (Decreasing)  
Pressand hold theeconomy mode button for 3 seconds.  
Change thetemperaturevaluebypressing “+” or “-” buttons.  
Press the economy mode button once to savethe changes youhavemade  
or wait10seconds.  
By pressing the Receiver's manual usage button for 2 seconds, youshould  
see the Orange Light blinking on the Receiver. In this way, after making  
sure that the heating/cooling unit is operating, press the same button  
again for 2 seconds and seethattheOrange LEDturns off.  
Set up the Room Thermostat to pair the Receiver with the Room  
Thermostat.  
You can use the “+” and “-” buttons to use the Room Thermostatmanually.  
1
2
3
4
GeneralDetails
NameGENERAL LIFE Senna 270S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.23 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE Senna 270S RF Wireless Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE Senna 270S RF Wireless Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE Senna 270S RF Wireless Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Receiver wiring diagram Digital room thermostat SENNA 270 RF is a wireless room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economic heating/cooling. Warning! Operations within the heating/cooling unit or the electrical installation must be carried out by professionally qualified persons. Different mode options (Comfort Mode and Economy Mode) Low battery warning: When the icon appears on the screen, it means “low battery warning”. Temperature sensors used in room thermostats are highly sensitive. You may need to calibrate your room thermostat if you would like to get the same temperature values with other thermometers in your living space. Receiver must be installed at least 50 cm away from the heating/cooling unit. Room thermostat needs to be placed in the room which is used most frequently. There are 2 modes in the room thermostat: Comfort Mode and Economy Mode.
  • Page 2: Warranty conditions outline the coverage for manufacturing defects for 5 years from the invoice date. The room thermostat operates using TPI technology, which helps maintain the desired temperature with minimal fluctuations. If the thermostat loses connection with the receiver for 22 minutes, it will stop heating or cooling for safety. The warranty covers repairs conducted at the company factory, with transportation costs borne by the customer. Malfunctions caused by customer misuse or external factors are not covered by the warranty. The learning process for TPI thermostats restarts if the device is de-energized or relocated. The thermostat's compatibility with heating/cooling units is confirmed if they have On-Off connections. Customers must report any product damages within the warranty period to maintain their rights. The warranty document must be retained by the customer; a replacement will incur a fee if lost. The manufacturer reserves the right to change product specifications and user manuals.