TROUBLESHOOTING  
Reset Operation  
function correctly contact your heating/cooling service person  
or place of purchase.  
Note: When thermostat is reset, installer configuration menu  
settings and programming will reset to factory settings.  
If a voltage spike or static discharge blanks out the display  
or causes erratic thermostat operation, you can reset the  
thermostat by removing the wires from terminals R and C  
(do not short them together) and removing batteries for 2  
minutes. After resetting the thermostat, replace the wires and  
batteries. If the thermostat has been reset and still does not  
Note: Be sure to review the installer configuration menu  
settings.  
To reset the programming, clock and configuration settings,  
press  
and  
and the FAN button simultaneously. The  
thermostat should go blank and then all segments will be  
displayed momentarily.  
Symptom  
Possible Cause  
Correction Action  
No Heat/No Cool/No Fan  
(common problems)  
1. Blown fuse or tripped circuit breaker.  
2. Furnace power switch to OFF.  
3. Furnace blower compartment door or  
panel loose or not properly installed.  
4. Loose connection to thermostat or  
system.  
Replace fuse or reset breaker.  
Turn switch to ON.  
Replace door panel in proper position to engage safety  
interlock or door switch.  
Tighten connections.  
No Heat  
1. Pilot light not lit.  
2. Furnace Lock-Out Condition. Heat  
may also be intermittent.  
Re-light pilot.  
Many furnaces have safety devices that shut down when  
a lock-out condition occurs. If the heat works intermittently  
contact the furnace manufacturer or local HVAC service  
person for assistance.  
3. Heating system requires service or  
thermostat requires replacement.  
Diagnostic: Set SYSTEM Switch to HEAT and raise the  
setpoint above room temperature. Within a few seconds  
the thermostat should make a soft click sound. This sound  
usually indicates the thermostat is operating properly. If  
the thermostat does not click, try the reset operation listed  
above. If the thermostat does not click after being reset  
contact your heating and cooling service person or place  
of purchase for a replacement. If the thermostat clicks,  
contact the furnace manufacturer or a HVAC service  
person to verify the heating is operating correctly.  
No Cool  
1. Cooling system requires service or  
thermostat requires replacement.  
Same as diagnostic for No Heat condition except set the  
thermostat to COOL and lower the setpoint below the room  
temperature. There may be up to a five minute delay before  
the thermostat clicks in Cooling.  
1. Possible short in wiring. Check each wire connection to verify they are not shorted  
2. Possible short in thermostat. or touching together. No bare wire should stick out from  
3. Possible short in heat/cool/fan system. under terminal block. Try resetting the thermostat as  
Heat, Cool or Fan  
Runs Constantly  
4. FAN Switch set to Fan ON.  
described above. If the condition persists the manufacturer  
of your system or service person can instruct you on how  
to test the Heat/Cool system for correct operation. If the  
system operates correctly, replace the thermostat.  
Thermostat Setting &  
Thermostat Thermometer  
Disagree  
1. Thermostat thermometer setting  
requires adjustment.  
The thermometer can be adjusted +/- 4 degrees. See  
Temperature Display Adjustment in the Configuration Menu  
section.  
Furnace (Air Conditioner)  
Cycles Too Fast or Too  
Slow (narrow or wide  
temperature swing)  
1. The location of the thermostat and/or  
the size of the Heating System may  
be influencing the cycle rate.  
Digital thermostats provide precise control and cycle faster  
than older mechanical models. The system turns on and off  
more frequently but runs for a shorter time so there is no  
increase in energy use. If you would like an increased cycle  
time, choose SL for slow cycle in the Configuration menu,  
step 6 (heat), 7 (cool) or 8 (heat pump). If an acceptable  
cycle rate is not achieved, contact a local HVAC service  
person for additional suggestions.  
9
GeneralDetails
NameWhite Rodgers 1F85CA-0471 Blue Universal Thermostat Instruction Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.37 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

White Rodgers 1F85CA-0471 Blue Universal Thermostat Instruction Manual