Home > WHITE RODGERS > White Rodgers 1E78 5 2 Day Programmable Thermostat Instruction Manual
White Rodgers 1E78 5 2 Day Programmable Thermostat Instruction Manual
CHECK THERMOSTAT OPERATION
CONTINUED FROM THIRD PAGE
5
Beforeyoubeginprogrammingyourthermostat,youshouldbefamiliar
with its features and with the display and the location and operation
of the thermostat buttons.Your thermostat consists of two parts: the
thermostat body and the base. To remove the body, gently pull it
straight out from the base.To replace the body, line up the body with
the base and press gently until the body snaps onto the base.
The Thermostat Buttons and Switches
1
(Up arrow) Raises temperature setting.
2
(Down arrow) Lowers temperature setting.
3
TIME button.
4
PRGM (program) button.
5
RUN (program) button.
6
HOLD button.
7
FAN switch (ON, AUTO).
8
SYSTEM switch (COOL, OFF, HEAT).
The Display
9
Indicates day of the week.
10
is displayed when the SYSTEM switch is in the HEAT posi-
tion.
is displayed (non-flashing) when the SYSTEM switch
is in the COOL position. is displayed (flashing) when the
compressor is in lockout mode.
Figure 8.Thermostat display, buttons and switches
11
12
Alternately displays current time and temperature.
• ENERGYMANAGEMENTRECOVERY—EnergyManagement
Recovery (EMR) causes the thermostat to start heating or cool-
ing early to make the building temperature reach the program
setpoint at the time you specify.Heating will start 5 minutes early
for every 1° of temperature required to reach setpoint. Cooling
will start approximately 15 minutes early for every 1° because
it takes longer to reach temperature. Clipping W903 jumper will
disable EMR.
is displayed when the 2 “AAA” batteries are low and
shouldbereplaced.Nothingelsewillbedisplayed.Earliermodels
display “LO BATTERY”. Refer to 37-7006.
13 Displays currently programmed set temperature (this is blank
when SYSTEM switch is in the OFF position).
14
“HOLD” is displayed when the thermostat is in the HOLD
mode.
Example:You select EMR and have your heating programmed
to 65° at night and 70° at 7 AM.If the building temperature is 65°
the difference between 65° and 70° is 5°.Allowing 5 minutes per
degree the thermostat setpoint will change to 70° at 6:35 AM.
Operating Features
Now that you are familiar with the thermostat buttons and display,
read the following information to learn about the many features of
the thermostat.
• SIMULTANEOUS HEATING/COOLING PROGRAM STOR-
AGE — When programming, you can enter both your heating
and cooling programs at the same time. There is no need to
reprogram the thermostat at the beginning of each season.
• °F/°C CONVERTIBILITY — The factory default setting is Fahr-
enheit. Clipping W904 jumper on the circuit board (see fig. 1)
will alter this feature to Celsius temperature setting.
• LOW BATTERY INDICATOR — If the 2 “AAA” alkaline bat-
teries are low and should be replaced, the display will be
blank except for
. When the batteries are low, pressing
• TEMPERATURE OVERRIDE — Press
or
until the
any button will cause the display to operate for ten seconds.
After ten seconds, the display will return to blank except for
display shows the temperature you want. The thermostat will
override current programming and keep the room temperature
attheselectedtemperatureuntilthenextprogramperiodbegins.
Then the thermostat will automatically revert to the program.
• HOLDTEMPERATURE—Thethermostatcanholdanytempera-
ture within its range for an indefinite period, without reverting to
theprogrammedtemperature.PressHOLD button.“HOLD”will
be displayed.Then choose the desired temperature by pressing
. After
has been displayed for 4 weeks, the
thermostat will raise the temperature 10 degrees above your
setpoint in COOL mode and will drop temperature 10 degrees
below your setpoint inHEAT mode.You cannot program with low
batteries, but you can override setpoint temperature.
• TEMPERATURE DISPLAY ADJUSTMENT — Your new ther-
mostat has been accurately set in our factory. However, if you
wish, you may adjust your new thermostat temperature display
to match your old thermostat.This can be accomplished (within
a 3° range) as follows:
or
. The thermostat will hold the room temperature
at the selected setting until you press the RUN button to start
program operation again.
| General | Details |
|---|---|
| Name | White Rodgers 1E78 5 2 Day Programmable Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.3 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual