Home > WHITE RODGERS > White Rodgers 1E78 5 2 Day Programmable Thermostat Instruction Manual
White Rodgers 1E78 5 2 Day Programmable Thermostat Instruction Manual
CAUTION
Take care when securing and routing wires so they do not
short to adjacent terminals or rear of thermostat. Personal
injury and/or property damage may occur.
REMOVING OLD THERMOSTAT
CONTINUED FROM FIRST PAGE
!
3
ATTENTION! This product does not contain mercury. However,
this product may replace a unit which contains mercury.
Do not open mercury cells.If a cell becomes damaged, do not touch
any spilled mercury. Wearing non-absorbent gloves, take up the
spilled mercury and place into a container which can be sealed. If a
cell becomes damaged, the unit should be discarded.
TERMINAL CROSS REFERENCE CHART
New Thermostat
Terminal Designation
Other Manufacturers’
Terminal Designation
*
Mercury must not be discarded in household trash. When the unit
this product is replacing is to be discarded, place in a suitable con-
containing mercury.
*
RH
RC
G
4
R
G
W
Y
RH
M
V
F
R5
R
R
-
-
G
G
4
G
W
Y
W
W
Y
H
C
Y
Y6
MOUNTING AND WIRING
4
* These are four-wire, single-transformer systems.
Factory installed jumper wire between the RH
and RC terminals must remain in place.
WARNING
!
Do not use on circuits exceeding specified voltage. Higher
voltage will damage control and could cause shock or fire
hazard.
Energy Management Recovery (EMR)
This thermostat is set to operate with EMR. This causes the
thermostat to start the heating or cooling system early to have
the room temperature reach the program setpoint at the time
the period is to start.
Do not short out terminals on gas valve or primary control
totest.Shortorincorrectwiringwilldamagethermostatand
could cause personal injury and/or property damage.
Thermostat installation and all components of the system
shall conform to Class II circuits per the NEC code.
To disable EMR, clip jumper W903 (see Fig. 1).
Attach Thermostat Base to Wall
Electric Heat or Single-Stage
Heat Pump Systems
1. Remove the packing material from the thermostat.Gently pull the
thermostat body straight off the base. Forcing or prying on the
thermostat will cause damage to the unit. If necessary, move the
electric heat switch (see ELECTRIC HEAT SYSTEMS, above).
This thermostat is configured from the factory to operate a heat/cool,
fossil fuel (gas, oil, etc.), forced air system. It is configured correctly
for any system that DOES NOT require the thermostat to energize
the fan on a call for heat. If your system is an electric or heat-pump
system that REQUIRES the thermostat to turn on the fan on a call
for heat, locate the GAS/ELECTRIC switch (see fig. 1) and switch it
to the ELECTRIC position.This will allow the thermostat to energize
the fan immediately on a call for heat.If you are unsure if the heating/
cooling system requires the thermostat to control the fan, contact a
qualified heating and air conditioning service person.
2. Connect wires beneath terminal screws on base using appropri-
ate wiring schematic (see figs. 2 through 7).
3. Place base over hole in wall and mark mounting hole locations
on wall using base as a template.
4. Move base out of the way. Drill mounting holes.
5. Fasten base loosely to wall, as shown in fig. 1, using two mount-
ing screws. Adjust until level, and then tighten screws. (Leveling
is for appearance only and will not affect thermostat operation.)
If you are using existing mounting holes, or if holes drilled are
too large and do not allow you to tighten base snugly, use plastic
screw anchors to secure subbase.
Hydronic (Hot Water or Steam)
Heating Systems
6. Push excess wire into wall and plug hole with a fire-resistant
material (such as fiberglass insulation) to prevent drafts from
affecting thermostat operation.
This thermostat is set to operate properly with a forced-air heating
system. If you have a hydronic heating system (a system that heats
with hot water or steam), you must set the thermostat to operate
properly with your system.
Battery Location
Thefactorydefaultsettingisforcedairheat.ClippingjumperW905on
thecircuitboardwillproducealongerheatingcyclewhichisnormally
for hot water or steam (hydronic) systems. Both settings produce a
very accurate temperature control and can be set to your personal
preference.As received, the thermostat cycles the system just under
1˚F. With W905 clipped, the system cycles at approximately 1.5˚F.
This thermostat requires 2 “AAA” alkaline batteries to operate.
If
appears on the display, the batteries are low and should be
®
replaced with fresh“AAA”Energizer alkaline batteries.The batteries
are located on the back of the thermostat body (see fig. 1).
| General | Details |
|---|---|
| Name | White Rodgers 1E78 5 2 Day Programmable Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.3 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual