uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual
Change the settings
03 ECO mode setback temperature
To enter the settings menu:
Default: 4 ˚C
1. Push and hold the OK button for approximately 3 seconds.
Setting range: 0 – 11 ˚C, 0.5 ˚C increments
2. The settings icon and menu numbers are displayed in the center
of the display.
In this menu, you can change the setback temperature for whenever
the channel is in ECO mode.
3. Use the - or + button to change the numbers to locate a
The setting adjusts the current setpoint with the set value. In heating
mode, the setpoint is decreased. In cooling mode, the setpoint is
increased.
submenu (see list below).
02
Heating/cooling changeover
If the setback temperature is set to 0, the thermostat will remain
unaffected if a program sets the system in ECO mode.
This menu is not visible if the thermostat is registered to a Uponor
Smatrix Base Pulse controller.
03
This menu is not visible if a communication module is connected to
the system. The setting is then available in the Uponor Smatrix Pulse
app.
ECO mode setback temperature
This menu is not visible if a communication module is connected to
the system. The setting is then available in the Uponor Smatrix Pulse
app.
See Change the settings, Page 9 , for how to change the setting.
04
04 Control mode
Default: 0
Control mode
05
Setting range: 0=RT, 1=RFT, 2=RO, 3=RS
High floor temperature limitation
This menu is only visible if control mode RFT is activated in settings
menu 04. For systems with a communication module, this menu only
shows the set value. Changes can be made in the Uponor Smatrix
Pulse app.
In this menu, you can set the control mode for the thermostat.
If an external sensor is connected to the thermostat, you must
choose a control mode to accommodate the extra functionality of the
sensor.
06
The current control mode is displayed (RT, RFT, RS or RO).
Low floor temperature limitation
This menu is only visible if control mode RFT is activated in settings
menu 04. For systems with a communication module, this menu only
shows the set value Changes can be made in the Uponor Smatrix
Pulse app.
See Change the settings, Page 9 , for how to change the setting.
Display
Display text
Thermostat function
RT
Room temperature sensor
07
Cooling allowed
RFT
RS
Room temperature sensor and
floor temperature sensor
This menu is not visible if a communication module is connected to
the system. The setting is then available in the Uponor Smatrix Pulse
app.
Remote sensor
08
Display unit
11
RO
Room temperature sensor and
outdoor temperature sensor
Room temperature calibration
4. Push OK to enter parameter edit mode.
The parameter starts to flash.
5. Change the parameters by pressing - or + button.
05 High floor temperature limitation
6. Push and hold the OK button for approximately 3 seconds to exit
the settings menu.
Note
This parameter must be higher than the 06 Low floor
temperature limitation.
02 Heating/cooling changeover
Default: 0
Default: 26 ˚C
Setting range: Heating/Cooling
Setting range: 20 – 35 ˚C, 0.5 ˚C increments
In this menu, you can set the maximum permitted floor temperature.
This menu is not visible if the thermostat is registered to a Uponor
Smatrix Base Pulse controller.
This menu is only visible if control mode RFT is activated in settings
menu 04. For systems with a communication module, this menu only
shows the set value. Changes can be made in the Uponor Smatrix
Pulse app.
See Change the settings, Page 9 , for how to change the setting.
See Change the settings, Page 9 , for how to change the setting.
|
|
Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual
9
| General | Details |
|---|---|
| Name | uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual |
| Make | uponor |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |