5 Troubleshooting  
5.1 General  
5.4 Digital thermostat alarms/  
problems  
This section describes general problems and alarms that can occur  
with the Uponor Smatrix system and gives solutions for them.  
Problems are frequently caused by loops that are installed incorrectly  
or by thermostats that are in the incorrect room or that are registered  
incorrectly.  
The display remains inactive after  
pressing a button  
Note  
The cable is not correctly positioned or a wire is damaged  
For more information, please refer to the Uponor OM  
Smatrix Base Pulse.  
Examine the wiring.  
Make sure that the thermostat is connected directly to the  
room controller with a short bus connection.  
If the thermostat operates correctly, examine the wiring  
(cable and connections). If problem continues, replace the  
thermostat.  
5.2 Troubleshooting after  
installation  
Note  
Communication failure icon is  
displayed in the alarm list  
For more information, please refer to the Uponor OM  
Smatrix Base Pulse.  
5.3 Flash-illuminated alarm  
symbols  
Icon  
Description  
CD0000779  
Communication lost indicator  
Figure 1. Example from a heating system operating in eco  
mode without demand, in control mode RO  
Faulty room temperature sensor  
+
+
The cable is not correctly positioned or a wire is damaged  
Examine the wiring.  
Faulty floor temperature sensor  
Make sure that the thermostat is connected directly to the  
room controller with a short bus connection.  
This symbol is only visible if control mode is set to  
RFT.  
If the thermostat operates correctly, examine the wiring  
(cable and connections). If problem continues, replace the  
thermostat.  
Faulty remote temperature sensor  
+
+
This symbol is only visible if control mode is set to  
RS.  
The thermostat is defective  
Faulty outdoor temperature sensor  
Change the temperature setpoint to cause the thermostat to  
transmit.  
This symbol is only visible if control mode is set to  
RO.  
Replace the thermostat.  
Relative humidity limit reached  
This symbol is only visible if cooling is active and  
RH control is enabled in the Uponor Smatrix  
Pulse app (which requires a communication  
module).  
Room temperature sensor icon is  
displayed in the alarm list  
CD0000780  
Figure 2. Example from a heating system operating in comfort  
mode without demand, in control mode RT  
Defective temperature sensor  
Speak to the installer or replace the thermostat.  
|
|
Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual  
11  
GeneralDetails
Nameuponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual
Makeuponor
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Uponor T-247 BUS Smatrix Base Thermostat Installation Guide
Uponor T-247 BUS Smatrix Base Thermostat Installation Guide
Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual
Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual

uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual