INITIAL SETTINGS  
OWNER’S  
MANUAL  
CONNECT THE POWER  
SUPPLY WIRES  
2
AND PROGRAMMING  
To begin with, follow the on-screen instructions to adjust your  
thermostat’s settings. Press  
to confirm.  
WARNING: Incorrectly connected electrical wires could  
result in a fire hazard.  
or  
to change your selection and  
PROGRAMMABLE ELECTRONIC THERMOSTAT  
FOR BASEBOARDS, CONVECTORS ANS FAN HEATERS  
Language: FRA / ENG (Français / English)  
Temperature format: °C / °F (Celsius / Fahrenheit)  
1. Complete the thermostat’s electrical connection according to  
the diagram below. Tighten the wires securely in the supplied  
wire connectors.  
ST402PFF  
Load type selection: CONV / FAN (Convection / Fan Heater).  
FAN HEATER mode is enabled by default.  
2. Push the wires and connectors into the electrical box.  
Lobby mode: STD / LBY (Standard room / Lobby).  
NOTE: If the electrical wires are aluminum, use CO/ALR connec-  
tors instead (not supplied).  
In LOBBY mode (LBY), the thermostat automatically provides  
100% heating for five minutes as soon as a sudden drop in  
temperature is detected. This mode can be useful for heaters  
located near an entrance. When this mode is activated, the  
icon flashes. LOBBY mode is available only if the heating mode  
selected is FAN HEATER.  
FOR BASEBOARDS, CONVECTORS AND FAN HEATERS  
Operation mode: PROG / MANUAL (Programmable / Manual).  
If you selected MANUAL mode, your thermostat is now ready to  
use! If you selected PROGRAMMABLE mode, configure the  
following settings:  
Date and time  
E
Automatic daylight savings time switchover: DST Y / DST N  
(Daylight savings time Yes / Daylight savings time No)  
1-844-STELPRO  
WWW.STELPRO.COM  
B
Program setpoint temperatures: (Wake, Leave, Return, Sleep)  
Monday to Friday program hours: [Mo-Fr] (Wake, Leave,  
Return, Sleep)  
L1=Black  
ER  
L2/N=Red  
LD=Yellow  
YELLOW  
The diagram shows a 240 V power supply.  
Saturday and Sunday program hours: [Sa-Su] (Wake, Sleep)  
The following table shows the default program values:  
FOR BASEBOARDS AND CONVECTORS ONLY  
WEEK DAYS  
IMPORTANT INSTRUCTIONS  
RETURN  
WAKE  
LEAVE  
SLEEP  
6:00 AM  
21°C / 70°F  
8:00 AM  
16°C / 61°F  
4:00 PM  
21°C / 70°F  
10:00 PM  
17°C / 63°F  
THE THERMOSTAT MUST BE INSTALLED BY A CERTIFIED  
ELECTRICIAN.  
WEEKEND DAYS  
Connect the thermostat to a 120 to 240 VAC power source ONLY and  
comply with load limits.  
WAKE  
SLEEP  
7:00 AM  
21°C / 70°F  
11:00 PM  
17°C / 63°F  
WARNING – HIGH VOLTAGE. Turn off the power supply before  
installation and maintenance. Leave at least 12 in. (30 cm)  
clearance around the thermostat to ensure that it is properly  
vented.  
B
L1=Black  
ER  
YELLOW  
L2/N=Red  
FEATURES  
LD=Yellow  
The diagram shows a 240 V power supply.  
SAVE THESE INSTRUCTIONS  
FOR BASEBOARDS AND CONVECTORS ONLY  
KEY FEATURES  
1. Press  
or once to lower or raise the setpoint temperature by  
0.5°C / 1°F. If you are in PROGRAMMABLE mode, the set-  
point change will be considered as a temporary override to the  
programming. The thermostat will return to PROGRAMMABLE  
mode when the next program begins. To cancel the override and  
TECHNICAL SPECIFICATIONS  
VOLTAGE AND LOAD  
return to PROGRAMMABLE mode, press  
2. Press once to switch from MANUAL to PROGRAMMABLE  
mode and vice versa.  
.
PRODUCT CODE  
SUPPLY VOLTAGE  
LOAD AT 120 V  
LOAD AT 240 V  
VOLTS  
WATTS  
WATTS  
ST402PFF  
120-240  
150-2000  
300-4000  
3. If Programmable mode is selected, press  
next program.  
twice to go to the  
B
Load control type  
Frequency  
Resistive  
60 Hz  
4. Press  
Then, press  
30, 40, 40, 50 or 60 minutes). The thermostat will then heat at  
and  
simultaneously to activate BOOST mode  
.
L1=Black  
Storage temperature  
-40°C to 50°C (-40°F to 122°F)  
or to select BOOST mode duration (10, 20,  
L2/N=Red  
YELLOW  
-20°C to 50°C (-4°F to 122°F).  
LC display less effective below 0°C (32°F)  
LD=Yellow  
The diagram shows a 240 V power supply.  
Operating temperature  
100% for the time specified. When BOOST mode is on, the time  
remaining is displayed on the screen. To cancel the BOOST  
Humidity  
5% to 98% without condensation  
Action  
Type 1.Y  
mode, press  
.
Pollution degree  
Software  
2
Class A  
Rated impulse voltage  
Category II overvoltage (1500 V)  
ADVANCED MENU ACCESS AND USE  
ATTACH THE THERMOSTAT  
3
Independently mounted control for surface mounting  
Thermistor used as a sensor, carries no load current  
1. Press and hold  
advanced menus.  
for 3 seconds to access the thermostat’s  
Overload protection device external to the control: circuit breaker (refer to local electrical code)  
2. Press  
or to change your selection.  
to confirm your selection and proceed to the next  
1. Using the alignment guide,  
hook the bottom [A] of the  
thermostat into the bottom of  
the plate. Be sure not to jam  
the wires between the thermo-  
stat and mounting plate.  
3. Press  
menu.  
BEFORE YOU GET STARTED  
4. Press and hold  
for 3 seconds to exit the advanced menus.  
ADVANCED MENU LIST  
• The box contains one (1) thermostat with mounting plate, two (2)  
mounting screws, three (3) twist-on wire connectors and one (1)  
owner’s manual.  
Language: FRA / ENG (Français / English)  
2. Rotate the thermostat upwards  
and attach it on the top hook of  
the mounting plate.  
Temperature format: °C / °F (Celsius / Fahrenheit)  
Load type selection: CONV / FAN (Convection / Fan Heater).  
FAN HEATER mode is enabled by default.  
To install this thermostat, you will need a #2 Phillips screwdriver.  
• Install your thermostat about 5 ft (1.5 m) from the floor on an  
inside wall facing the heating system.  
Lobby mode: STD / LBY (Standard room / Lobby).  
A
LOBBY mode is available only if the heating mode selected is  
FAN HEATER.  
3. Tighten the screw at the top of the  
thermostat [B] to hold it in place  
securely.  
B
Operation mode: PROG / MANUAL (Programmable / Manual)  
When PROGRAMMABLE mode is selected, you can change  
the following settings:  
INSTALLATION  
4. Restore the power at the circuit  
breaker.  
Date and time  
Automatic daylight savings time switchover: DST Y / DST N  
(Daylight savings time Yes / Daylight savings time No)  
NOTE: If you need to remove the  
thermostat, follow step 1 in section  
1, then use a straight screwdriver  
to unhook it from the top of the  
mounting plate.  
ATTACH THE MOUNTING PLATE  
1
Program setpoint temperatures: (Wake, Leave, Return, Sleep)  
Monday to Friday program hours: [Mo-Fr] (Wake, Leave,  
Return, Sleep)  
A
WARNING: Turn off the  
power supply.  
Saturday and Sunday program hours [Sa-Su] (Wake, Sleep)  
Keypad lock: LOCK / UNLOCK (Lock keypad / Unlock keypad)  
Reset thermostat to default values: RST N / RST Y (No / Yes)  
1. Loosen the screw [A] at the  
top of the thermostat without  
removing it.  
INTERFACE  
USING THE TECHNICAL MENUS:  
2. Separate the mounting plate  
from the thermostat. Pull the  
top of the plate and rotate.  
1. Press  
for 10 seconds to access the thermostat’s technical  
This thermostat is programmable. PROGRAMMABLE mode allows  
you to define the setpoint temperature according to time of day and  
day of the week. (See the INITIAL SETTINGS AND PROGRAMMING  
section.) You can also use this thermostat in MANUAL mode, i.e. the  
setpoint temperature will be constant.  
menus (the advanced menu will appear after 3 seconds but  
continue to hold for another 7 seconds).  
MOUNTING  
PLATE  
2. Use  
ou to change your selection.  
3. Press  
menu.  
to confirm your selection and continue to the next  
3. Take the power wires [B] out of the junction box and  
run them through the large opening in the center of the  
mounting plate [C].  
Touch the keypad once to activate the backlight, then you can  
make changes  
4. Press  
for 3 seconds to exit the thermostat’s technical menus.  
TECHNICAL MENU LIST  
4. Using the two (2) mounting screws provided [D], attach the  
thermostat mounting plate to the junction box. The plate  
can be centered on the junction box or shifted to the left  
or right.  
Heating output  
t1: Maximum room temperature setpoint limit  
(5°C to 30°C / 41°F to 86°F). The default setting is 30°C.  
Keypad locked  
Fan mode  
(LOBBY mode is active  
when flashing)  
t2: Minimum room temperature setpoint limit  
(5°C to 30°C / 41°F to 86°F). The default setting is 5°C.  
Période de la  
semaine (Lu-Ve:  
du lundi au vendredi,  
Sa-Di: le samedi  
et le dimanche)  
NOTE: The maximum setpoint limit must be higher than the mini-  
mum setpoint limit, and the minimum setpoint limit must be lower  
than the maximum setpoint limit.  
B
Ambient  
temperature/  
contextual  
information  
Menu indicator  
Current program  
(Wake, Leave,  
Return, Sleep)  
D
t3: Year of production  
t4: Month of production  
t5: Identification number  
t6: Software version  
C
JUNCTION BOX  
Keypad  
t7: Thermostat control code  
D
MOUNTING PLATE  
Limited three-year warranty. See details on www.stelpro.com.  
STELPRO DESIGN INC. Saint-Bruno-de-Montarville, Québec, Canada, J3V 6L7  
GeneralDetails
NameSTELPRO ST402PFF Programmable Electronic Thermostat Owner’s Manual
MakeStelPro
LanguageEnglish
FiletypePDF (Download)
File size0.41 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
STELPRO STF362NP Floor Heating Thermostat Owner’s Manual
STELPRO STF362NP Floor Heating Thermostat Owner’s Manual
STELPRO ST302P Programmable Electronic Thermostat Owner’s Manual
STELPRO ST302P Programmable Electronic Thermostat Owner’s Manual
STELPRO SAT402ZB Smart Thermostat User Guide
STELPRO SAT402ZB Smart Thermostat User Guide
STELPRO ST252NPFF Non-Programmable Electronic Thermostat Owner’s Manual
STELPRO ST252NPFF Non-Programmable Electronic Thermostat Owner’s Manual
STELPRO ASMC402 Maestro Zigbee Smart Programmable Thermostat User Guide
STELPRO ASMC402 Maestro Zigbee Smart Programmable Thermostat User Guide
STELPRO SIBTE12C Electronic Thermostat Owner’s Manual
STELPRO SIBTE12C Electronic Thermostat Owner’s Manual
STELPRO STZW402+ Electronic Thermostat for The Smart Home Owner’s Manual
STELPRO STZW402+ Electronic Thermostat for The Smart Home Owner’s Manual
STELPRO SIBTE13F Electronic Thermostat User Guide
STELPRO SIBTE13F Electronic Thermostat User Guide
STELPRO STCP MULTIPLE PROGRAMMING ELECTRONIC THERMOSTAT User Guide
STELPRO STCP MULTIPLE PROGRAMMING ELECTRONIC THERMOSTAT User Guide
STELPRO STCP Floor Heating Thermostat Multiple Programming User Guide
STELPRO STCP Floor Heating Thermostat Multiple Programming User Guide

STELPRO ST402PFF Programmable Electronic Thermostat Owner’s Manual
Get the free PDF manual for the STELPRO ST402PFF Programmable Electronic Thermostat Owner’s Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

STELPRO ST402PFF Programmable Electronic Thermostat Owner’s Manual Overview

Summary of Contents

  • Page 1: initial settings connect the power supply wires to begin with, follow the on-screen instructions to adjust your thermostat’s settings. incorrectly connected electrical wires could result in a fire hazard. the thermostat must be installed by a certified electrician. connect the thermostat to a 120 to 240 VAC power source only and comply with load limits. turn off the power supply before installation and maintenance. the diagram shows a 240 V power supply. this thermostat is programmable. programming mode allows you to define the setpoint temperature according to time of day and day of the week.