4.3 Main screen  
The display below shows the main screen after activation:  
C
Setpoint  
D
E
F
G
H
I
High limitation of floor temperature  
Low limitation of floor temperature  
Control mode, Room temperature  
sensor  
CD0000795  
Control mode, Room temperature  
sensor and floor temperature  
sensor  
4.4 Change setpoint  
On the main screen, pressing the or + button for the first time will  
switch the display from the main screen to the setpoint adjustment  
screen, where the current setpoint value will be shown.  
Control mode, Remote sensor  
The change setpoint display could show any of the symbols listed  
below:  
Control mode, Room temperature  
sensor and outdoor temperature  
sensor  
J
Outdoor temperature sensor  
Floor temperature sensor  
Relative humidity  
K
L
CD0000788  
The setpoint adjustment screen can display various icons, including  
those for ECO/Comfort mode, Heating/Cooling, Demand/No  
Demand, Regulation mode, and units. However, not all icons are  
shown simultaneously; they appear according to the current system  
status.  
M
N
Pairing not ok  
Communication lost  
Pairing ok  
Active communication  
(flashes to indicate active  
communication during run  
mode)  
When the or + buttons are pressed, the setpoint adjusts in 0,5°  
increments. Once the desired setpoint is selected, either pressing the  
OK button or waiting for 10 seconds of inactivity will cause the display  
to return to the main screen.  
O
Temperature unit  
4.5 Sensor readings  
P
Q
R
S
Temperature  
Settings menu  
Calibration  
Demand  
This thermostat has a RH sensor that measures the room's relative  
humidity. When the regulation mode is set to RFT or RO, an external  
sensor measures a second temperature (floor temperature for RFT or  
outdoor temperature for RO). To see the readings from the other  
sensors, press the OK button on the main screen.  
Regulation mode is RT or RS  
OK  
10 sec  
of inactivity  
T
Heating/cooling mode  
Comfort/ECO mode  
U
CD0000796  
Only one temperature will be measured, which is already  
displayed on the main screen.  
When you press the OK button, the display switches from the  
main screen to the humidity measurement screen.  
After 10 seconds of inactivity, the display will automatically return  
to the main screen.  
|
|
Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual  
7
GeneralDetails
Nameuponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual
Makeuponor
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Uponor T-247 BUS Smatrix Base Thermostat Installation Guide
Uponor T-247 BUS Smatrix Base Thermostat Installation Guide
Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual
Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual

uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual