Floor temperature sensor icon is  
displayed in the alarm list  
Outdoor temperature sensor icon is  
displayed in the alarm list  
CD0000781  
CD0000783  
Figure 3. Example from a heating system operating in eco  
mode without demand, in control mode RFT  
Figure 5. Example from a heating system operating in comfort  
mode with demand, in control mode RO  
Defective temperature sensor  
Defective temperature sensor  
Make sure that the floor sensor is connected correctly.  
Make sure that the outdoor sensor is connected correctly.  
Disconnect the temperature sensor and examine it with an  
ohmmeter. Make sure that the value agrees with the  
temperature sensor diagram.  
Disconnect the temperature sensor and examine it with an  
ohmmeter. Make sure that the value agrees with the  
temperature sensor diagram.  
Incorrect thermostat control mode  
Incorrect thermostat control mode  
Select the correct thermostat control mode (settings  
menu 4).  
Select the correct thermostat control mode (settings  
menu 4).  
Temperature sensor not connected  
Connect the temperature sensor.  
Temperature sensor not connected  
Connect the temperature sensor.  
Remote temperature sensor icon is  
shown in the alarm list  
Relative humidity icon is displayed in  
the alarm list  
CD0000784  
CD0000782  
Figure 4. Example from a cooling system operating in comfort Figure 6. Example from a cooling system operating in comfort  
mode without demand, in control mode RS  
mode without demand, in control mode RT  
Defective temperature sensor  
Note  
Make sure that the remote sensor is connected correctly.  
Relative humidity control is activated in the Uponor  
Smatrix Pulse app (requires communication module).  
Disconnect the remote temperature sensor and examine it  
with an ohmmeter. Make sure that the value agrees with the  
temperature sensor diagram.  
The relative humidity limit is reached  
Start a dehumidifier or increase the supply temperature  
setpoint to lower the humidity level.  
Incorrect thermostat control mode  
Select the correct thermostat control mode (settings  
menu 4).  
Temperature sensor not connected  
Connect the temperature sensor.  
5.5 Speak to the installer  
For the installer’s contact information, refer to the installation report.  
Prepare this information before you speak to an installer:  
Installation report  
Drawings of the underfloor heating system (if available)  
List of all alarms, including times and dates  
|
|
12 Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual  
GeneralDetails
Nameuponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual
Makeuponor
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Uponor T-247 BUS Smatrix Base Thermostat Installation Guide
Uponor T-247 BUS Smatrix Base Thermostat Installation Guide
Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual
Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual

uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual