uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual
06 Low floor temperature limitation
4.7 Factory reset
Note
Note
This parameter must be lower than the 05 High floor
temperature limitation.
Do not do a factory reset of the thermostat unless it is
absolutely necessary.
Default: 20 ˚C
Note
Setting range: 10 – 30 ˚C, 0.5 ˚C increments
In this menu, you can set the minimum permitted floor temperature.
A factory reset erases the registration data from the
thermostat.
This menu is only visible if control mode RFT is activated in settings
menu 04. For systems with a communication module, this menu only
shows the set value Changes can be made in the Uponor Smatrix
Pulse app.
See Change the settings, Page 9 , for how to change the setting.
07 Cooling allowed
In this menu it is set whether cooling is allowed in the room or not.
This menu is not visible if a communication module is connected to
the system. The setting is then available in the Uponor Smatrix Pulse
app.
See Change the settings, Page 9 , for how to change the setting.
SI0000866
08 Display unit
In this menu, you can set the temperature unit (°C or °F) that you
want to see on the display.
Follow the instructions below to reset the thermostat (factory
reset):
Display
Display text
Description
1. Hold all three keys ― and O (OK) and + for 10 seconds
°C
Degrees Celsius
2. The assignment to the controller is removed, and all parameter
values are restored to their default settings
°F
Degrees Fahrenheit
3. The thermostat initiates a restart.
See Change the settings, Page 9 , for how to change the setting.
11 Room temperature calibration
Default: 0.0 ˚C
Setting range: -6.0 – 6.0 ˚C, 0.1 ˚C increments
In this menu, you can calibrate the room temperature shown on the
thermostat display.
See Change the settings, Page 9 , for how to change the setting.
|
|
10 Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual