uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual
6 Technical data
6.1 Technical specifications
6.2 Performance curves
Description
Value
Product name
Uponor Smatrix Base thermostat
D+RH T-247 BUS
External temperature sensor resistance
diagram
IP
IP20, class III (IP: degree of
inaccessibility to active parts of the
product and degree of water)
kΩ
100
90
80
70
60
50
40
30
20
10
0
Max. ambient RH (relative
humidity)
85 % at 20 °C
Marking
CE
ERP
Class IV
Low-voltage tests
EN 60730-1* and EN 60730-2-9**
EMC (electromagnetic compatibility EN 60730-1
requirements) tests
Power supply
Voltage
From room controller
4,5 V to 5,5 V
2500 V
-20 -10
0
10
20
30
40
50
60
70
80 °C
Rated impulse voltage
Temperature (°C)
Resistance (kΩ)
Pollution degree
2 - Normal household environment
-20
-10
0
94
Software class
A
54
Operating temperature
Storage temperature
Connection terminals
0 °C to +45 °C
-10 °C to +65 °C
32
10
20
30
40
50
60
70
80
20
13,5 A/250 V/4 kV/3/
IEC61984/0,08 – 1,5 mm2
12.5
8
Purpose of control
Thermostat
5.3
3.6
2.5
1.8
1.3
Construction of control
Electronic independently mounted
control
Terminal method of disconnection
Type Y
Temperature for ball pressure test 75 °C
*) EN 60730-1 Automatic electrical controls for household and similar
use -- Part 1: General requirements
**) EN 60730-2-9 Automatic electrical controls for household and
similar use -- Part 2-9: Particular requirements for temperature
sensing controls
6.3 Dimensions
21 mm
86 mm
Regulatory conformance
The Uponor Smatrix Base thermostat D+RH T-247 BUS complies
with the following directives.
•
•
CE
UKCA
EU/UK Declaration of conformity
Hereby, Uponor declares that the Uponor Smatrix Base
thermostat D+RH T-247 BUS is in compliance with the
relevant Community harmonisation legislation. 1)
ZD0000120
The full text of the EU/UK declaration of conformity is
available at the following internet address:
1) Refer to the related Uponor product for the specified certification
and compliance marks.
Additional product information and instructions are delivered with the
services/download-centre and at the national Uponor websites in
local language.
|
|
14 Uponor Smatrix Base thermostat D+RH T-247 BUS Operation manual
| General | Details |
|---|---|
| Name | uponor D Plus RH T-247 BUS Smatrix Base Thermostat Instruction Manual |
| Make | uponor |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |

Uponor T-247 BUS Smatrix Base Thermostat Installation Guide

Uponor ETN4 Ecoflex Supra Standard Thermostat Instruction Manual