5.2 Application Endpoint #1 –Thermostat  
supported  
Description  
Cluster  
Basic  
Provides basic information about the device, such as the manufacturer ID,  
vendor and model name, stack profile, ZCL version, production date,  
hardware revision etc. Allows a factory reset of attributes, without the device  
leaving the network.  
server  
0x0000  
Identify  
server  
server  
0x0003  
0x0004  
Allows to put the endpoint into identify mode. Useful for identifying/locating  
devices and required for Finding & Binding.  
Groups  
Allows adding this endpoint to one or more groups. Afterwards the endpoint  
can be addressed using the group address. This is also a prerequisite for  
scenes. You may also query group membership and delete group  
associations.  
Scenes  
Allows storing one or more scenes per group, where each scene consists of a  
pre-set on/off state value. You may either store the current values as a  
scene, or provide scene settings when adding a scene, or delete scenes.  
server  
0x0005  
server  
server  
Thermostat  
0x0201  
0x0702  
Simple Meter  
Electrical Measurement  
server  
server  
0x0b04  
0x0009  
Measuring power, voltage, current  
Alarm  
Device related alarm  
client  
Server  
server  
Occupancy Sensing  
0x0406  
0x000a  
0x0204  
Time  
Thermostat User Interface Configuration  
5.2.1 Basic -0x0000 (Server)  
Attributes supported:  
Type  
Description  
Attribute  
ZCLVersion  
INT8U,  
0x0000  
0x03  
read-only  
ApplicationVersion  
INT8U ,  
0x0001  
0x0002  
0x0003  
0x0004  
0x0005  
0x0006  
0x0007  
This is the firmware version number of the application  
read-only  
INT8U ,  
StackVersion  
read-only  
HWVersion  
INT8U ,  
Hardware version 1  
read-only  
ManufacturerName  
string,  
“NAMRON AS”  
read-only  
ModelIdentifier  
string,  
“4512737 & 4512738”  
read-only  
DateCode  
string,  
NULL  
read-only  
PowerSource  
ENUM8,  
Device power supply, fixed value 0x01 Mains (single phase)  
read-only  
GeneralDetails
Namenamron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
MakeNAMRON
LanguageEnglish
FiletypePDF (Download)
File size0.47 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
namron 1402746 Touch Thermostat Instruction Manual
namron 1402746 Touch Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual

namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual