Installation
a.Installation must be done by a qualified electrician.
b.Power supply must be turned off during installation.
(1) Wiring diagram
L
N
4512737
NTC
L
L
N
N
Floor temp
sensor
(2) Mounting
a. Remove the display unit and front cover by using a small screwdriver.
b. Insert the wires to the correct terminals as presented in the wiring diagram above. Suggested
wire-stripping length is 8-10mm.
c. Fix the thermostat into the connection box by tightening the screws. Make sure that the thermostat is
fixed without deformation. Suggested torque is 0.2-0.4Nm (2.0-4.1kgf.cm).