Enum8,  
ControlSequenceOfOperation  
0x001B  
0x0029  
reportable  
Set device supported operation type, here only supports Heating Only(0x02)  
Map16,  
HVAC relay state/ ThermostatRunningState  
read-only,  
reportable  
Indicates the relay on/off status, here only supports bit0( Heat State)  
Proprietary Attributes:  
Manufacturer  
Description  
code  
Type  
Attribute  
OperateDisplayLcdBrightnesss  
OLED brightness when operate the buttons:  
ENUM8,  
Value=0 : Low Level  
0x1000  
0x1224  
0x1224  
reportable  
Value=1 : Mid Level(default)  
Value=2 : High Level  
ButtonVibrationLevel  
Key beep volume & vibration level:  
Value=0 : off(default)  
ENUM8  
0x1001  
reportable  
Value=1 : Low Level  
Value=2 : High Level  
FloorSenserType  
Select external (Floor) sensor type:  
Value=5 : NTC 12K/25  
ENUM8  
Value=4 : NTC 100K/25  
Value=3 : NTC 50K/25  
0x1002  
0x1224  
reportable  
Value=2 : NTC 15K/25  
Value=1 : NTC 10K/25 (Default)  
ControlType  
The referring sensor for heat control:  
Value=0 : Room sensor(Default)  
Value=1 : floor sensor  
ENUM8  
0x1003  
0x1004  
0x1224  
0x1224  
reportable  
Value=2 : Room+floor sensor  
PowerUpStatus  
ENUM8  
The mode after reset power of the device:  
Value=0 : default mode  
reportable  
Value=1 : last status before power off (Default)  
FloorSenserCalibration  
INT8S,  
0x1005  
0x1006  
0x1224  
0x1224  
The temp compensation for the external (floor) sensor, range  
is -30-30, unit is 0.1°C. default value 0  
reportable  
DryTime  
INT8U  
The duration of Dry Mode, range is 5-100, unit is min.  
Default value is 5.  
reportable  
ModeAfterDry  
The mode after Dry Mode:  
Value=0 : OFF  
ENUM8  
0x1007  
0x1224  
Value=1 : Manual mode  
Value=2 : Auto mode –schedule (default)  
Value=3 : Away mode  
reportable  
TemperatureDisplay :  
Value=0 : Room Temp (Default)  
Value=1 : Floor Temp  
ENUM8  
0x1008  
0x1009  
0x1224  
0x1224  
reportable  
WindowOpenCheck  
The threshold to detect open window, range is 0.3-8, unit is  
INT8U  
0.5ºC,  
reportable  
0 means disabled, default is 0  
GeneralDetails
Namenamron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
MakeNAMRON
LanguageEnglish
FiletypePDF (Download)
File size0.47 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
namron 1402746 Touch Thermostat Instruction Manual
namron 1402746 Touch Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual

namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual